5.5
Connecting the automatic spray gun
See also
Chapter 5.4 ‘Connection scheme’ on page 16
.
WARNING!
Danger of injury due to improper connection!
When the fluid supply is pressurised, e.g. from pressure containers or with pumps, the range
of the fluid jet can increase by a multiple in case of atomisation air failure. This presents a
hazard to people and property.
–
Make sure that the fluid supply and the control air are interrupted if the atomisation air
pressure drops off quickly.
–
It is recommended to regulate the atomisation air pressure via a filter pressure reducer.
The connections for control and atomisation air are marked with letter abbreviations.
Fig. 6: Connecting the automatic spray gun
1.
Connect the control air to input "St" (Fig. 6/2).
2.
Connect the atomisation air to input "Z" (Fig. 6/4).
3.
Connect the fluid line to (Fig. 6/1 or 3).
4.
For models with circulation connection, connect the second fluid line to the fluid connection
(Fig. 6/5).
Operating instructions
T-Dok-144-GB-Rev.1
[email protected], www.krautzberger.com
GB–18