background image

Page 

5

  of 

20

 

 

IMPORTANT SAFEGUARDS 

Before 

the 

appliance

 is used, it must be properly positioned and installed as described 

in this manual, so read the manual carefully. We strongly recommend that you have a 
professional install your new machine.  The warranty may be affected or voided by 
an incorrect installation. To reduce the risk of fire, electrical shock or injury when 
using the 

appliance

, follow basic precautions, including the following: 

 

        DANGER       

 

 

It is recommended that a separate circuit, serving only your 

appliance

, be provided. Use receptacles that cannot 

be turned off by a switch or pull chain.

 

  Please ensure that the required voltage is being supplied at all times. 

  The unit should be plugged into a grounded and properly-sized electrical outlet with appropriate over-current 

protection. 

  Ensure unit is not resting on or against the electrical cord. 

 

Do not connect or disconnect the electric plug when your hands are wet.

 

 

Never unplug the 

appliance

 by pulling on the power cord. Always grip the plug firmly and pull straight out from the 

outlet.

 

 

Never clean 

appliance

 parts with flammable fluids. Do not store or use gasoline or other flammable vapors and 

liquids in the vicinity of this or any other appliance. The fumes can create a fire hazard or explosion.

 

 

Before proceeding with cleaning and maintenance operations, make sure the power line of the unit is disconnected.

 

 

Unplug the 

appliance

 or disconnect power before cleaning or servicing. Failure to do so can result in electrical 

shock or death.

 

  If the unit is not in use for a long period of time, best to unplug the unit from the outlet. 

  After unplugging or a power outage to the unit, wait at least 10 minutes before plugging it back in. Failure to do so 

could cause damage to the compressor. 

  Do not operate the appliance with a frayed or crimped power cord. 

 

Do not attempt to repair or replace any part of your 

appliance

 unless it is specifically recommended in this manual. A 

qualified technician should do all other servicing or repairs.

 

        WARNING         

  Use two or more people to move and install appliance. Failure to do so can result in back or other injury. 

  This appliance must be properly installed and located in accordance with the Installation Instructions before it is used. 

  Do not touch the cold surfaces in the appliance compartment when hands are damp or wet. Skin may stick to these 

extremely cold surfaces.

 

  Setting temperature controls to the ZERO (0) position does not remove power from the appliance, it must be turned 

off at the unit appliance circuit breaker or by unplugging it.

 

 

To ensure proper ventilation for your 

appliance

, choose a well-ventilated area with temperatures above 50ºF 

(10ºC) and below 86ºF (30ºC). If in an environment with a temperature between 86 and 104ºF (30 to 40ºC) use of 
a fan blowing into the utility compartment or similar auxiliary cooling of that area is required. This unit MUST be 
installed in an area protected from the elements, such as wind, rain, water spray or drips.

 

 

The 

appliance

 should not be located next to ovens, grills or other sources of high heat.

 

 

It is important for the 

appliance

 to be level for proper operation.  You may need to make adjustments to level it.

 

 

Remove the packing materials & be sure to discard them as the work area is policed. Clean the 

appliance

 before using.

 

 

Do not use this apparatus for other than its intended purpose.

 

 

Only trained, qualified personnel should attend to & monitor the appliance’s performance and upkeep.

 

 

Do not attempt to use the shelving as a ladder.

 

 

Содержание 68K-759HC

Страница 1: ...12 10 2020 PK SERVICE INSTALLATION AND INSTRUCTION MANUAL 68K 759HC 68K 773HC 69K 887HC 69K 888HC REACH IN REFRIGERATOR PLEASE READ CAREFULLY ...

Страница 2: ...OPERATION 9 Refrigerated cycle 9 Power Switch 9 SOLID STATE THERMOSTAT DESCRIPTIONS 9 1 FRONT PANEL COMMANDS 9 2 MAIN FUNCTIONS 10 3 ALARM SIGNALLING 10 TIPS FOR PROPER OPERATION CLEANING AND MAINTENANCE 11 CLEANING AND MAINTENANCE 12 Exterior and Interior Cleaning of Appliances 12 Cleaning the Condenser Coil 12 Stainless Steel Care and Cleaning 13 Gasket Maintenance 13 Doors Hinges 13 Drain Maint...

Страница 3: ...s manufactured by Argus that have been altered in any way including the use of any parts and or other components not specifically approved by Argus Argus reserves the right to make design changes and or improvements at any time Specifications and designs are subject to change without notice SERIAL NUMBER INFORMATION l The serial number of all self contained freezers is located inside the unit on t...

Страница 4: ...cessary damage forms upon request 7 Retain all crating material until an inspection has been made or waived APPLIANCE SAFETY Always read and obey all safety messages This is the Safety Alert Symbol This symbol alerts you to potential hazards that can injure or kill you and others All safety messages will follow the Safety Alert Symbol and either the words DANGER WARNING OR CAUTION DANGER DANGER me...

Страница 5: ...e to the unit wait at least 10 minutes before plugging it back in Failure to do so could cause damage to the compressor Do not operate the appliance with a frayed or crimped power cord Donotattempttorepairorreplaceanypartofyourapplianceunlessitisspecificallyrecommended in this manual A qualified technician should do all other servicing or repairs WARNING Use two or more people to move and install ...

Страница 6: ...ord that has been crimped shows cracks or has frayed insulation abrasion damage along its length or at either end When moving the appliance be careful not to damage the power cord Power Surges Connecting the unit to the incorrect voltage or oversized circuit protection i e a breaker rated for over 20 amps is not covered by the appliance warranty Neither is a damaged power cord using unauthorized e...

Страница 7: ... as a fully loaded unit can weigh as much as 1500 pounds Reinforce the floor as necessary to provide for maximum loading For the most efficient refrigeration be sure to provide good air circulation inside and out Inside cabinet Do not pack the units so full that air cannot circulate The refrigerated air is discharged at the top rear of the unit It is important to allow for proper air flow from the...

Страница 8: ...rted from right hand hinged to left hand hinged and vice versa by removing the door hinges from both the door and unit reversing their locations and reattaching them and re hanging the door upside down NOTICE Unit repairs will not be subject to standard unit warranties if due to improper installation procedures or utilizing an unqualified installer technician to commission the unit Electrical Conn...

Страница 9: ... 2 Anti condensation heaters on door frames work in conjunction with the compressor 3 Recommended holding temperature range 34 to 41 F 1 to 5 C 4 Comes factory set to 37 F 3 C Power Switch The power switch is located on the front of the bottom panel When the unit is on the switch will glow green SOLID STATE THERMOSTAT DESCRIPTIONS 1 FRONT PANEL COMMANDS To display target set point in programming m...

Страница 10: ...ey for more than 2 seconds and a manual defrost will start 2 4 TO LOCK THE KEYBOARD 1 Keep pressed for more than 3s the and keys 2 The OF message will be displayed and the keyboard will be locked If a key is pressed more than 3s the OF message will be displayed 2 5 TO UNLOCK THE KEYBOARD Keep pressed together for more than 3s the and keys till the on message will be displayed 3 ALARM SIGNALLING 3 ...

Страница 11: ...mes a year using an ice bath Digital pocket thermometers may be off by as much as 1 8 F when measuring refrigerated products 9 For best performance the ambient conditions should be less than 80 F with a relative humidity below 65 10 Ensure the automatic defrost cycle is set to keep the evaporator fan coil free of ice with proper air flow or the unit won t maintain the right temperature The set poi...

Страница 12: ...ondenser coil If heavy grease is present there are de greasing agents available for refrigeration use and specifically for the condenser coils The condenser coil may require cleaning with the de greasing agent and then blown clear with compressed air or CO2 Failure to maintain a clean condenser coil can initially cause high temperatures and excessive run times Continuous operation with dirty or cl...

Страница 13: ... cleaning solution Many food products have an acidic content which can deteriorate the finish Be sure to clean the stainless steel surfaces of all food products Gasket Maintenance Gaskets require regular cleaning to prevent mold and mildew build up and also to keep the elasticity of the gasket Gasket cleaning can be done with the use of warm soapy water Avoid full strength cleaning products on gas...

Страница 14: ... too close to the wall The tray is not in the correct position The fan blade may be obstructed or unbalanced Clear the fan blade obstruction or replace the fan Compressor is Not Running Fuse blown or circuit breaker tripped Replace fuse or reset circuit breaker If replacement of fuse or reset of circuit breaker doesn t correct the problem contact a qualified service technician Power cord unplugged...

Страница 15: ...l pressures to equalize The door does not close tightly The door is bent A replacement door may be necessary The door gasket has come out Reposition or replace the gasket The unit is not level Level the unit again Hinge has loosened Tighten the door hinge and ensure it is secure SERVICE AND TROUBLESHOOTING TIPS 1 The compressor comes with a 5 year limited warranty 1 year parts and labor and the su...

Страница 16: ...Page 16 of 20 DIMENSIONS AND TECHNICAL INFORMATION 68K 759HC 68K 773HC t 69K 887HC 69K 888HC t ...

Страница 17: ...20 COMPONENT INFORMATION REFRIGERATION DIAGRAM R290A REFRIGERANT DOUBLE DOOR MODELS SINGLE DOOR MODELS POWER SWITCH THERMOSTAT CONTROL PANEL POWER SWITCH THERMOSTAT CONTROL PANEL RIGHT DOOR LEFT DOOR DOOR CASTERS ...

Страница 18: ...Page 18 of 20 WIRING DIAGRAMS SINGLE DOOR MODELS DOUBLE DOOR MODELS ...

Страница 19: ... 3 SKC 2 110 0625 0 Shelf Clip 12 4 SKA 2 140 0002 0 Caster 2 5 SKA 2 140 0001 0 Caster with brake 2 DOUBLE DOOR MODELS Item Part Number Descriptions Qty Unit 1 SKA 2 110 0047 0 Gasket door 2 2 SKA 2 120 0015 0 Shelf 6 3 SKC 2 110 0625 0 Shelf Clip 24 4 SKA 2 140 0002 0 Caster 2 5 SKA 2 140 0001 0 Caster with brake 2 5 1 2 3 4 2 3 4 5 1 ...

Страница 20: ... providers to expedite technical support and repair if it is necessary in the future PRIMARY CONTACT SECONDARY CONTACT Firm Name Firm Name Email Email Phone No Phone No Street Address Street Address NOTES NOTES 7750 Georgetown Road Indianapolis IN 46268 USA Phone 317 634 2550 ...