Table 4. Minimum dimensions fortable burners in a table, countertop or housing.
Min.
Depth
Min.
Width
Min. height for table, housing or
countertop with space reserved
for the gas cylinder or without
Max.
Height of
housing
Max. height of
where the burner
can be placed
AQF 01
545 mm
545 mm
850 mm
1500
1000
AQF 02
545 mm
621 mm
850 mm
1500
1000
AQF 03
637 mm
637 mm
850 mm
1500
1000
AQF 04
545 mm
751 mm
850 mm
1500
1000
AQF 05
637 mm
751 mm
850 mm
1500
1000
AQF 06
545 mm
881 mm
850 mm
1500
1000
AQF 07
637 mm
881 mm
850 mm
1500
1000
PLEASE NOTE:
When the appliance is installed it has to be insulated up to minimum 100 mm on each side even it is
non-combustible table / countertop just to prevent the heat transfer into the table / countertop.
The minimum recommended safety distance is 200 mm from the edge of the outer insulation made
for the burner. It is a distance that should be kept so that the possibility of contact with fire by persons
requiring care is hindered. It should also be remembered that this dimension does not guarantee the
safety of avoiding burns of nearby people if they do not comply with the instructions. It is the user's
responsibility to secure the place where the gas garden fireplace will be installed against unauthorized
contact with the fire / appliance of children, the elderly, inform and all other persons requiring special
care.
The minimum safety distance above the gas table burner is 1500 mm. It means that installation of the
appliance at a distance shorter than mentioned to combustible materials is forbidden. This can be
installed in the non-combustible housing only even if the distance will be shorter but still, it has to
match this requirement when applies to the combustible materials behind the non-combustible
housing.
Even when the housing distances to combustible materials are in line with above requirements, this is
still forbidden to install the housing with the appliance in the area that will not comply with the amply
ventilated area requirements.
Please note that noncombustible housing
still must have at least one side wall open above the burner
pit. Every housing for appliance and its gas cylinder must have an easy access door for a gas cylinder
and ventilation holes at minimum of 0,1 m
2
.
The space indicated above is the minimum free space from flammable materials, unless this is
removed by another entry. Failure to observe the above clearances (free space) may result in a fire
or damage to health and property.
PLEASE NOTE: The device has been designed for installation in a special housing or tables provided
by the manufacturer or in accordance with the safety requirements presented in this section of the
manual. The entire housing / table must meet the requirements of safety standards, including slip
tests. If the device is installed on a table or cabinet that does not meet the specified requirements,
the manufacturer is not responsible for any accidents or damages that may occur to the customer,
user or property.
Содержание AQF 01
Страница 4: ...WYMIARY URZ DZENIA AQF 01 AQF 02...
Страница 5: ...AQF 03 AQF 04...
Страница 6: ...AQF 05 AQF 06...
Страница 7: ...AQF 07 Rys 1 Zwymiarowane rysunki wszystkich wariant w ogrodowego paleniska gazowego...
Страница 19: ...Rys 4 Schemat pod czenia systemu r cznego sterowania gazem...
Страница 32: ...APPLIANCES DIMENSIONS AQF 01 AQF 02...
Страница 33: ...AQF 03 AQF 04...
Страница 34: ...AQF 05 AQF 06...
Страница 35: ...AQF 07 Fig 1 Dimensional drawings of all variants of the gas garden fireplace...
Страница 47: ...Fig 3 Connection diagram for the manual gas control system...