15
Commissioning
Usage with detergents
- The detergent must have the ph-value 7-9 neutral.
- Wait until the pump has pressed the air out of the lines.
- Put the chemical filter into a container with detergent.
- Open the detergent valve (20). The pump now sucks detergent in and mixes it
with the high pressure spray.
- Set the desired concentration of detergent.
- At the end of the working procedure with detergent reset the rotary button
to „O“.
- When the high pressure cleaner is operated with open chemistry valve
without chemicals, the pump sucks in air. Damages caused to the pump as
a result are not covered by the guarantee.
Comply with additive manufacturers’ instructions (e.g. protective
equipment and waste water regulations). Use only additives approved
for use with high pressure cleaners. Using other additives impairs
the safety of the machine.
In the interest of the environment and to keep expenditure down, we
recommend sparing use of detergent. Please observe the
recommendations of the detergent manufacturer.
After using detergents, rinse the machine for approx. 2 minutes by
pressing the trigger of the spray gun.
Usage as a cold water high pressure cleaner
- Leave the ignition "OFF". Rocker switch (1A) to „0“.
- Start cleaning
Usage as a hot water high pressure cleaner
- Set the target temperature on the thermostat to min. 40 °C and than switch the
ignition "ON" (rocker switch).The oil burner starts to work. The water is heated up
and kept at the temperature you have set.
During high-pressure operation (above 30 bars) the temperature may not exceed 90 °C.
Steam level
To reach the steam level, i.e. over 90 ° C water temperature
, adjust the pressure and
the water quantity downwards using the handwheel ( 4 ) and choose the desired
temperature of max. 150 °C with the thermostat. For high pressure cleaners with hose
drum applies: The hose must always be fully unwound.
During steam operation the pressure may not exceed 30 bars.
Содержание 11/130
Страница 30: ...30 Complete Assembly...
Страница 32: ...32 Electronics switchbox...
Страница 36: ...36 Combustion chamber...
Страница 38: ...38 Combustion chamber...
Страница 44: ...44 Valve housing...
Страница 48: ...48 Hose drum Special accessory Upgrade kit 44 152 2...
Страница 56: ...Reprint only allowed with the authorization of As date of 15 04 2009 Order No 30 702 1 R...