background image

 

 

Step 4:  Connect inputs and outputs 

Always switch OFF the power on each device before connecting it to your 

WP-DEC7

 

RS-232 Configuration 

 

Grounding the 

WP-DEC7

 (Optional) 

RS-232 Control 

 

 

 

1. 

Connect the ring tongue terminal to the building grounding point wire 
(a green-yellow, AWG#18 (0.82mm2) wire, crimped with a proper 
hand-tool is recommended). 

2. 

Insert the M3x8 screw through the toothed lock washer, the tongue 
terminal and the washer in the order shown above. 

3. 

Insert the M3x8 screw (with toothed lock washer ring tongue terminal 
and washer) into the grounding screw hole and tighten the screw. 

Baud Rate:  

115,200 

 

Data Bits:  

 

Stop Bits:  

 

Parity:  

None 

 

 

 

 

 

Connecting the audio output

 

To a balanced 
stereo audio 
acceptor:

 

 

To an unbalanced 
stereo audio 
acceptor:

 

 

Connecting an 
Unbalanced Stereo 
Audio Source to the 
Balanced Input

 

 

 

 

To achieve specified extension distances, use the recommended Kramer cables available a

www.kramerav.com/product/WP-DEC7

Using third-party cables may cause damage! 

  

Содержание WP-DEC7

Страница 1: ...detected 3 ON LED Flashes Red On fallback address acquiring device ON LED flashes continuously in slow 0 5 10sec cadence Lights Green When power is on Flashes Green slowly Device is in standby mode Flashes Green fast FW is downloaded in the background Flashes Green very fast for 60sec A device identification command is sent Flag me Lights Yellow Device falls back to default IP address Lights Red S...

Страница 2: ...12 RS 232 3 pin Terminal Block Connector Connect to an RS 232 device to use as a Gateway and bi directional serial control signal extension even when no AV signal is extended Step 3 Install WP DEC7 Insert the device into the in wall box note that first you need to connect the RS 232 and LAN POE RJ 45 Connector cables and or power and connect the parts as shown in the illustration EU UK Version US ...

Страница 3: ...washer the tongue terminal and the washer in the order shown above 3 Insert the M3x8 screw with toothed lock washer ring tongue terminal and washer into the grounding screw hole and tighten the screw Baud Rate 115 200 Data Bits 8 Stop Bits 1 Parity None Connecting the audio output To a balanced stereo audio acceptor To an unbalanced stereo audio acceptor Connecting an Unbalanced Stereo Audio Sourc...

Страница 4: ... example if the device is connected directly to a laptop the device gets the default IP address If this IP address is already in use the system searches for an unused IP in the range of 192 168 X Y and the allocated IP address can be identified using the Kramer KDS 7 MNGR Setting the Channel Number The connected decoder should be tuned to the encoder channel You can set the channel number on the d...

Отзывы: