WP-501 - Overview 

 

 

Overview 

The 

WP-501

 is an all-in-one AV solution for classrooms, training rooms and similar 

simple AV installations. It enables remote projector or flat panel control and the 

routing of one of three A/V sources to the inputs of a display device via the front 

panel buttons. The 

WP-501

 

Consists of two VGA inputs, each with an unbalanced stereo audio signal 

(one on the front panel and the other on the rear panel), one composite 

video input (on the rear panel) with an unbalanced stereo audio signal, and 

a dynamic or condenser microphone input  

 

Includes an RGBHV output, a composite video output and two identical 

audio outputs 

 

Includes bidirectional RS-232 and IR out for controlling the display device 

 

Has two relay ports for control of other room items related to the AV system 

such as raising and lowering drapes, the screen or the projector 

 

Has two analog volume control adjustment knobs, one for the selected 

PC/Video audio signal and the other for microphone volume adjustment 

 

Features four dedicated front panel buttons, one for turning the projector 

ON/OFF and the other three for selecting which input to route to the 

projector. Each button can be programmed to perform command macros  

 

Is Kramer Site-CTRL™ compatible, for network remote control and 

management over the Ethernet port 

Kramer Site-CTRL is a powerful A/V asset management tool. It offers real-time network 
monitoring and control of Kramer Master controllers installed at an A/V site and all the 
connected A/V equipment. The Kramer Site-CTRL downloadable version can monitor 
and control up to 100 Kramer Master controllers. For larger installations, a similar 
solution is also available 

 

Includes an Ethernet port for remote control and management from the 

Kramer Site-CTRL™ software and for accessing the stored Web pages 

 

Can store EDID information and support EDID communication with the 

connected PC sources (the default EDID is already uploaded upon delivery); 

a specific EDID can be uploaded via the Kramer K-Config software 

 

Has a USB port for programming via a computer 

 

Is available worldwide as a 3 Gang USA wall plate 

Содержание WP-501

Страница 1: ...KRAMER ELECTRONICS LTD USER MANUAL MODEL WP 501 Wall Plate Solution for Simple Room Control and Signal Switching P N 2900 000753 Rev 1...

Страница 2: ...g Your WP 501 7 5 1 Set the WP 501 8 5 2 Connecting the WP 501 9 5 3 Operating the WP 501 11 6 Technical Specifications 12 Figures UFigure 1 WP 501 Front PanelU 4 UFigure 2 WP 501 Rear PanelU 5 UFigur...

Страница 3: ...defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Matrix Switchers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Sp...

Страница 4: ...er manuals application programs and to check if firmware upgrades are available where appropriate 2 1 Achieving the Best Performance To achieve the best performance Use only good quality connection ca...

Страница 5: ...d the other for microphone volume adjustment Features four dedicated front panel buttons one for turning the projector ON OFF and the other three for selecting which input to route to the projector Ea...

Страница 6: ...ns ED12 and ED15 pass the EDID informa ion 4 AUDIO 1 3 5mm mini jack Connect to the unbalanced stereo audio signal of the PC1 source 5 VOLUME PC VIDEO Adjustment Knob Rotate clockwise to increase the...

Страница 7: ...onnect to the local computer network for accessing the stored Web pages for remote control and management from the Kramer Site CTRL software and for remote configuration file and firmware updates uplo...

Страница 8: ...onent Description 1 M3X6 screw 2 1 8 Toothed Lock Washer 3 M3 Ring Tongue Terminal To ground the WP 501 1 Connect the Ring Tongue terminal to the building grounding point wire it is recommended to use...

Страница 9: ...r technical personnel or by an external system integrator The installation process is not detailed in this user manual and includes configuration via the Kramer K Config Windows based configuration so...

Страница 10: ...h is set to dynamic It is recommended to set the mic mode switch before mounting the WP 501 front panel see Section 5 2 1 Factory Reset Button Disconnect the power and then connect it while pressing t...

Страница 11: ...pin HD and 3 5mm mini jack respectively A microphone to the MIC IN 3 5mm mini jack see Section 5 2 1 Figure 5 Connecting the WP 501 Front Panel 2 On the rear panel connect A computer graphics source a...

Страница 12: ...ts to the audio input of the video and PC inputs on the projector You can connect either AUDIO OUT 1 or AUDIO OUT 2 to either the PC or the CV input of the projector since both audio outputs are ident...

Страница 13: ...by the technical installer to configure the WP 501 front panel SELECT buttons to set a sequence of actions in a trigger a macro and assign them to any of the buttons such as those defined in the foll...

Страница 14: ...RS 232 on terminal block connectors 1 USB connector DEFAULT IP ADDRESS 192 168 1 39 SUPPORTED BAUD RATES FOR RS 232 1200 2400 4800 9600 19200 38400 57600 115200 DEFAULT EDID INFORMATION Standard timi...

Страница 15: ...nature ii Product modification orfailure to follow instructions supplied withtheproduct iii Repair orattemptedrepairby anyone not authorized by Kramer iv Any shipment of theproduct claims must bepres...

Страница 16: ...ributors visit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site E mail www kramerelectronics com info kramerel com SAFETY WARNING Di...

Отзывы: