The Kramer Protocol 2000 RS-232/RS-485 communication uses four bytes of 

information as defined below. All the values in the table are decimal, unless 

otherwise stated. 

 

 

 

 

 

 

 

 

MSB 

 

 

 

 

 

 

LSB 

1st Byte 

DESTINATION 

INSTRUCTION 

N5 

N4 

N3 

N2 

N1 

N0 

 

 

 

 

 

 

 

 

2nd Byte 

INPUT 

I6 

I5 

I4 

I3 

I2 

I1 

I0 

 

 

 

 

 

 

 

 

3rd Byte 

OUTPUT 

O6 

O5 

O4 

O3 

O2 

O1 

O0 

 

 

 

 

 

 

 

 

4th Byte 

 

 

MACHINE NUMBER 

OVR 

M4 

M3 

M2 

M1 

M0 

 

 

 

 

 

 

 

 

 
1st Byte: 

Bit 7 

– Defined as 0 

– DESTINATION: 

– Sends information to the switchers (from the PC) 

– Sends information to the PC (from the switcher) 

N5…N0 – INSTRUCTION 

The 6-bit INSTRUCTION defines the function performed by the switcher(s). If a function is performed using the 
machine’s keyboard, these bits are set with the INSTRUCTION NO. performed. The instruction codes are defined 
according to the table b

elow (INSTRUCTION NO. is the value set in N5…N0). 

 
2nd Byte: 

Bit 7 

– Defined as 1 

 

I6…I0 – INPUT 

When switching (i.e. instruction codes 1 and 2), the 7-bit INPUT is set as the input number to be switched. If switching is 
done using the machine’s front panel, these bits are set with the INPUT NUMBER switched. For other operations, these 
bits are defined according to the table. 
 
3rd Byte: 

Bit 7 

– Defined as 1 

 

O6…O0 – OUTPUT 

When switching (i.e. instruction codes 1 and 2), the 7-bit OUTPUT is set as the output number to be switched. If 
switching is done using the machine’s front panel, these bits are set with the OUTPUT NUMBER switched. For other 
operations, these bits are defined according to the table. 
 
4th Byte:  

Bit 7 

– Defined as 1  

 

Bit 5 

– Don’t care  

 

OVR 

– Machine number override 

 

 

M4…M0 – MACHINE NUMBER 

This byte is used to address machines in a system by their machine numbers. When several machines are controlled 
from a single serial port, they are usually configured together and each machine has an individual machine number. If 
the OVR bit is set, then all machine numbers accept (implement) the command and the addressed machine replies. 
When a single machine is controlled over the serial port, always set M4…M0 to 1, and make sure that the machine itself 
is configured as MACHINE NUMBER = 1. 

 

 
 
 
 
 
 
 
 
 

im Vertrieb von            CAMBOARD Electronics

www.camboard.de

Tel. 07131 911201
Fax 07131 911203

[email protected]

Содержание VS-84HN

Страница 1: ...RAMER ELECTRONICS LTD USER MANUAL MODEL VS 84HN 8x4 HDMI Matrix Switcher P N 2900 300157 Rev 7 im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard d...

Страница 2: ...im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de...

Страница 3: ...and Protocol 3000 15 6 6 Connecting via RS 232 15 6 7 Connecting via Ethernet 15 6 8 Upgrading the Firmware 17 7 Technical Specifications 18 8 Default Communication Parameters 19 9 Default EDID 20 10...

Страница 4: ...on GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Routers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP 7...

Страница 5: ...cables we recommend Kramer high performance high resolution cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quali...

Страница 6: ...002 96 EC aims to reduce the amount of WEEE sent for disposal to landfill or incineration by requiring it to be collected and recycled To comply with the WEEE Directive Kramer Electronics has made arr...

Страница 7: ...nsures Plug and Play operation for HDMI systems Kramer reKlocking Equalization Technology that rebuilds the digital signal to travel longer distances A lock button to prevent unwanted tampering with t...

Страница 8: ...OUT 1 to 4 Press to select an output to switch followed by an input also used for storing machine setups see Section 6 3 7 IN 1 to 8 Press to select the input to switch after selecting an output also...

Страница 9: ...Gateway 192 168 1 1 Depress the button while powering on the device The device powers up with the factory default IP parameters 18 REMOTE IR Opening Connect to an external IR receiver for controlling...

Страница 10: ...This distance can be extended to up to 60 meters when used with three extension cables Model C A35M A35F 50 Before using the external IR receiver be sure to arrange for your Kramer dealer to insert th...

Страница 11: ...nstalling in a Rack 4 Installing in a Rack This section provides instructions for rack mounting the unit im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info...

Страница 12: ...ources for example DVD players to the IN HDMI connectors You do not have to connect all the sources 2 Connect the four OUT HDMI connectors to up to four HDMI acceptors for example LCD displays with bu...

Страница 13: ...Connecting the VS 84HN 8x4 HDMI Matrix Switcher Figure 3 Connecting the VS 84HN 8x4 HDMI Matrix Switcher im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info...

Страница 14: ...the firmware see Section 6 8 6 1 Switching an Input to an Output To switch an input to an output Press an output button followed by an input button to switch the selected input to the selected output...

Страница 15: ...flashing 6 2 2 Acquiring the EDID from Different Outputs to Different Inputs To acquire the EDID from several outputs for example OUT 1 to IN 1 and OUT 4 to IN 3 1 Connect the display devices to the...

Страница 16: ...ut 2 1 Press the EDID and STO buttons simultaneously and hold them for 3 seconds Both buttons flash 2 Press the input for example Input 2 to which the EDID is to be copied The selected input number fl...

Страница 17: ...times out To recall a preset for example preset 10 1 Press the RCL button The RCL button flashes 2 Press the relevant OUT or IN button that stored the preset for example IN 6 preset 10 3 Press the RC...

Страница 18: ...onnect the RS 232 9 pin D sub on the rear panel of the VS 84HN via a 9 wire straight cable only pin 2 to pin 2 pin 3 to pin 3 and pin 5 to pin 5 need to be connected to the RS 232 9 pin D sub port on...

Страница 19: ...al Area Connection Properties 4 Select Properties The Local Area Connection Properties window appears 5 Select the Internet Protocol TCP IP and click the Properties Button see Figure 5 Figure 5 Local...

Страница 20: ...connect the Ethernet port of the VS 84HN to the Ethernet port on a network hub or network router via a straight through cable with RJ 45 connectors 6 8 Upgrading the Firmware For instructions on upgra...

Страница 21: ...ons infrared remote control transmitter RS 232 Ethernet OPERATING TEMPERATURE 0 to 40 C 32 to 104 F STORAGE TEMPERATURE 40 to 70 C 40 to 158 F HUMIDITY 10 to 90 RHL non condensing DIMENSIONS 19 x 7 x...

Страница 22: ...1 0x01 0x81 0x81 0x81 Example Output 1 to Input 1 AV 1 1 CR Switching Protocol P2000 P3000 P3000 P2000 Command 0x38 0x80 0x83 0x81 Command P2000 CR Front Panel Press and hold Output 1 and Output 3 si...

Страница 23: ...nge 31 94kHz Vertical scan range 50 85Hz Video bandwidth 170MHz CVT standard Not supported GTF standard Not supported Additional descriptors None Preferred timing Yes Native preferred timing 1280x720p...

Страница 24: ...0Hz 16 9 Modeline 1920x1080 74 250 1920 2448 2492 2640 1080 1084 1094 1124 interlace hsync vsync Detailed timing 4 1280x720p at 60Hz 16 9 Modeline 1280x720 74 250 1280 1390 1430 1650 720 725 730 750 h...

Страница 25: ...physical address 1 0 0 0 Maximum TMDS clock 165MHz Report information Date generated 08 03 2011 Software revision 2 52 0 857 Data source Real time 0x0031 Operating system 5 1 2600 2 Service Pack 3 im...

Страница 26: ...s set as the input number to be switched If switching is done using the machine s front panel these bits are set with the INPUT NUMBER switched For other operations these bits are defined according to...

Страница 27: ...performs the instruction and if the instruction is performed due to a keystroke operation on the front panel then these codes are sent For example if the HEX code 01 85 88 83 was sent from the PC the...

Страница 28: ...chine which is being addressed not to the system For example if six 16X16 matrices are configured to make a 48X32 system 48 inputs 32 outputs the reply to the HEX code 3E 82 81 82 ie request the numbe...

Страница 29: ...Delimiter Command SP Parameter_1 Parameter_2 CR 11 1 1 2 Command String Formal syntax with commands concatenation and addressing Start Address Body Delimiter device_id Command_1 Parameter1_1 Parameter...

Страница 30: ...more than one command Commands are separated by a pipe character Message starting character For host command query For device response Device ID Optional for K NET K NET Device ID followed by Query s...

Страница 31: ...s Some commands have short name syntax in addition to long name syntax to allow faster typing The response is always in long syntax 11 1 6 Chaining Commands Multiple commands can be chained in the sam...

Страница 32: ...et count End User LDEDID Load EDID data User SW Internal LOCK FP LCK Lock front panel Administrator LOCK FP LCK Read Lock front panel End User MODEL Read device model End User P2000 Switch to protocol...

Страница 33: ...im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de...

Страница 34: ...be found We welcome your questions comments and feedback Web site www kramerelectronics com E mail info kramerel com P N 2900 300157 Rev 7 SAFETY WARNING Disconnect the unit from the power supply bef...

Отзывы: