Connecting a VS-81DVI-R 8x1 DVI Switcher 

 

7

6  Connecting a VS-81DVI-R 8x1 DVI Switcher 

To connect the 

VS-81DVI-R

 

8x1 DVI Switcher

 (as illustrated in Figure 2), do 

the following

1

1.  Connect up to 8 DVI sources (for example, DVI computer graphics sources) 

to the INPUT connectors. 

2.  Connect the OUTPUT connector to the DVI acceptor (for example, a DVI 

display). 

3.  If required, connect a PC and/or controller to the RS-232 port (see section 6.1) 

and/or the ETHERNET port (see section 6.2). 

4.  Connect the power connector to the mains electricity. 

After turning on the power, press an INPUT SELECTOR button (1 to 8) to 

choose which DVI input to route to the output

2

                                                       

 

1  Switch  OFF  the  power  on  each  device  before  connecting  it  to  your  VS-81DVI-R.  After  connecting  your  VS-81DVI-R, 
switch on its power and then switch on the power on each device 
2 If the input is connected and active, the respective input button illuminates 

Содержание VS-81DVI-R

Страница 1: ...Kramer Electronics Ltd USER MANUAL Model VS 81DVI R 8x1 DVI Switcher...

Страница 2: ...r 8 Figure 3 Connecting a PC without using a Null modem Adapter 9 Figure 4 RJ 45 PINOUT 10 Figure 5 Local Area Connection Properties Window 11 Figure 6 Internet Protocol TCP IP Properties Window 11 Fi...

Страница 3: ...ER on again The front panel display initially shows a blinking E followed by the input numbers from 1 to 8 that blink until the unit has completed reading the EDID While the machine is acquiring the E...

Страница 4: ...rial Port Manager Kramer RC IR1 Infra Red Remote Control Transmitter3 including the required battery and a separate user manual4 Power cord This user manual4 2 Getting Started We recommend that you Un...

Страница 5: ...s may be cascaded Automatically reads and stores in non volatile memory the EDID1 block of the display device Does not support HDCP High Definition Digital Content Protection Includes a MUTE button to...

Страница 6: ...via a particular server or workstation of data HTML pages or e mails that is sent in packets across the Internet Every device connected to an IP network must have a unique IP address This address is...

Страница 7: ...Your VS 81DVI R 8x1 Switcher KRAMER SIMPLE CREATIVE TECHNOLOGY 4 Figure 1 VS 81DVI R 8x1 DVI Switcher...

Страница 8: ...input 1 6 PANEL LOCK Button Press to disengage the front panel buttons Table 3 VS 81DVI R 8x1 DVI Switcher Rear Panel Features Feature Function 7 INPUT DVI I Connectors Connect to the DVI D sources f...

Страница 9: ...nt protection and supply wiring Refer to the appropriate nameplate ratings for information For example for fuse replacement see the value printed on the product label 5 The machine is earthed grounded...

Страница 10: ...3 If required connect a PC and or controller to the RS 232 port see section 6 1 and or the ETHERNET port see section 6 2 4 Connect the power connector to the mains electricity After turning on the po...

Страница 11: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Connecting a VS 81DVI R 8x1 DVI Switcher 8 DVI Graphics Source 8 RS 232 DVI Display DVI Graphics Source 1 Figure 2 Connecting a VS 81DVI R 8x1 DVI Switcher...

Страница 12: ...9 wire flat cable to the RS 232 DB9 port on your PC To connect a PC to the VS 81DVI R unit without using a Null modem adapter Connect the RS 232 DB9 port on your PC to the RS 232 DB9 rear panel port...

Страница 13: ...J 45 PINOUT EIA TIA 568A Side 1 EIA TIA 568B Side 2 PIN Wire Color PIN Wire Color 1 White orange 1 White green 2 Orange 2 Green 3 White green 3 White orange 4 Blue 4 Blue 5 White blue 5 White blue 6 G...

Страница 14: ...rnet Protocol TCP IP and click the Properties Button see Figure 5 Figure 5 Local Area Connection Properties Window 6 Select Use the following IP Address and fill in the details as shown in Figure 6 7...

Страница 15: ...as described in section 6 2 1 2 Insert the CD ROM in the CD ROM drive double click the SetFC11_xx exe1 file and follow the on screen instructions2 Both the Ethernet Configuration Manager and the Virt...

Страница 16: ...ion 6 Device Network Settings Area DHCP 1 Mode Check Box When selected configures the Ethernet port to obtain an IP address automatically from the DHCP server When cleared manual configuration of the...

Страница 17: ...Virtual Serial Port Manager Application The Virtual Serial Port Manager window appears see Figure 8 Figure 8 The Virtual Serial Port Manager Window 2 Press the Add VSP button to add a serial port and...

Страница 18: ...connection according to your virtual serial port connections see Figure 11 Figure 11 The Port Window Selecting a Virtual Serial Port 6 3 2 Setting an Ethernet Connection If the control application ca...

Страница 19: ...5Vpp TTL RESOLUTION Up to UXGA POWER SOURCE 100 264VAC 50 60Hz CONTROLS Front panel buttons Infra red remote control transmitter RS 232 Ethernet DIMENSIONS 19 inch W 7 inch D 1U H WEIGHT 2 5 kg 5 5 l...

Страница 20: ...riginal dated invoice or a copy must be presented as proof of warranty coverage and should be included in any shipment of the product Please also include in any mailing a contact name company address...

Страница 21: ...For the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions comme...