Kramer Electronics Ltd.
VS-88H2
–
Operating
VS-88H2 via Front Panel Buttons
25
Copying the EDID
You can copy the EDID to an input from a connected output or use the default EDID.
To copy the EDID from a connected output:
1. Press and hold
EDID
and
STO
.
Both buttons illuminate,
VS-88H2
enters the EDID mode, and the 7-segment display
shows the current EDID status:
On the front panel button:
Both input and output buttons are dark.
On the 7-segment display:
“
d
” under an output number indicates that the input port is set to the default EDID.
“
L
” under an output number indicates that the EDID was uploaded externally from a file
via web page.
A digit under an output number indicates the output from which the EDID was copied.
2. Press one or more input buttons (or
ALL
).
The 7-segment display LEDs of the selected inputs flash.
3. Press the output button (with a connected display) corresponding to the output from
which you want to copy the EDID.
4. Press
EDID
.
Wait for about 5 seconds for the device to copy the EDID from the connected display.
To copy the default EDID:
1. Press and hold
EDID
and
STO
.
Both buttons illuminate,
VS-88H2
enters the EDID mode, and the 7-segment display
shows the current EDID status.
2. Press one or more input buttons (or
ALL
).
The 7-segment display LEDs of the selected inputs flash.
3. Press a disconnected output button.
4. Press
EDID
.
Wait for about 5 seconds for the device to copy the default EDID to the selected inputs.