![Kramer VS-44HC Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/kramer/vs-44hc/vs-44hc_user-manual_2001357015.webp)
Connecting the VS-44HC
11
6.3 Setting the Dipswitches
Figure 5 illustrates the factory default
dipswitches:
OFF
ON
1 2 3 4 5 6 7 8
Figure 5: Dipswitch Settings
Table 4: Dipswitch Settings
DIPS
Function
Description
1, 2, 3, 4 Machine #
Set the MACHINE # (see section 6.3.1)
5
Reserved
OFF
6
S/PDIF
ON for IN 2 S/PDIF digital audio signal;
OFF when TOSLINK is selected (see section 6.3.2)
1
7
Optic
ON for IN 2 TOSLINK digital audio signal;
OFF when S/PDIF is selected (see section 6.3.2)
1
8
RS-485
Termination
ON for RS-485 Line Termination with 120 ;
OFF for no RS-485 Line Termination
6.3.1
Setting the Machine #
To control a unit via RS-232 or RS-485, each unit has to be identified via its
unique MACHINE #. Set the machine #
2
on a
VS-44HC
unit via dipswitches
1, 2, 3 and 4, according to Table 5.
Table 5: Machine # Dipswitch Settings
DIPSWITCH
DIPSWITCH
MACHINE #
1
2
3
4
MACHINE #
1
2
3
4
1
ON OFF OFF OFF
9
ON OFF OFF ON
2
OFF ON OFF OFF
10
OFF ON OFF ON
3
ON ON OFF OFF
11
ON ON OFF ON
4
OFF OFF ON OFF
12
OFF OFF ON ON
5
ON OFF ON OFF
13
ON OFF ON ON
6
OFF ON ON OFF
14
OFF ON ON ON
7
ON ON ON OFF
15
ON ON ON ON
8
OFF OFF OFF ON
When connecting more than one
VS-44HC
unit, set a different machine # on
each unit. You do not have to number the units in the sequence order as they
connect to the PC, but it is essential that each unit is assigned a unique
machine number.
1 Do not set both DIP 6 and DIP 7 ON
2 When using a single unit, set the unit to MACHINE # 1