Kramer Electronics Ltd.
VS-44H2A
– Protocol 3000
38
Protocol 3000 Commands
Function
Description
Syntax
Parameters/Attributes
Example
#
Protocol handshaking.
Validates the Protocol
3000 connection and gets
the machine number.
Step-in master products
use this command to
identify the availability of a
device.
COMMAND
#
<CR>
FEEDBACK
~nn@
ok
<CR><LF>
#
<CR>
AUD-LVL
Set volume level.
COMMAND
#AUD-LVL
io_mode
,
io_index
,
vol_level
<CR>
FEEDBACK
~nn@AUD-LVL
io_mode
,
io_index
,
vol_level
<CR><LF>
io_mode
– Input/Output
0
– Input
1
– Output
io_index
– Number that indicates the
specific input or output port:
1-N (N= the total number of input or
output ports)
vol_level
– Volume level -60db to
30dB;
++
(increase current value by 1dB);
--
(decrease current value by 1dB)
Set AUDIO OUT 2 level
to -50dB:
#AUD-LVL
1
,
1
,
-50
<CR>
AUD-LVL?
Get volume level.
COMMAND
#AUD-LVL?
io_mode
,
io_index
<CR>
FEEDBACK
~nn@AUD-LVL
io_mode
,
io_index
,
vol_level
<CR><LF>
io_mode
– Input/Output
0
– Input
1
– Output
io_index
– Number that indicates the
specific input or output port:
1-N (N= the total number of input or
output ports)
vol_level
– Volume level -60db to
30dB
Get AUDIO OUT 1 level
#AUD-LVL?
1
,
1
<CR>
AV-SW-
TIMEOUT
Set auto switching timeout.
COMMAND
#AV-SW-TIMEOUT
switching_mode
,
time_out
<CR>
FEEDBACK
~nn@AV-SW-TIMEOUT
switching_mode
,
time_out
<CR><LF>
switching_mode
– Switching mode
0
– Video signal lost
1
– New video signal detected
2
– Audio signal lost
3
– Audio signal detected
4
– Disable 5V on video output if no
input signal detected
5
– Video cable unplugged
6
– Audio cable unplugged
7
– Video signal lost for signal routed
as a result of a manual override
action
8
– CEC monitor standby command
time_out
– Timeout in seconds
0 - 60000
Set the auto switching timeout
to 5 seconds in the event of 5V
disable when no input signal is
detected:
#AV-SW-TIMEOUT
4
,
5
<CR>
AV-SW-
TIMEOUT?
Get auto switching
timeout.
COMMAND
#AV-SW-TIMEOUT?
switching_mode
<CR>
FEEDBACK
~nn@AV-SW-TIMEOUT
switching_mode
,
time_out
<CR><LF>
switching_mode
– Switching mode
0
– Video signal lost
1
– New video signal detected
2
– Audio signal lost
3
– Audio signal detected
4
– Disable 5V on video output if no
input signal detected
5
– Video cable unplugged
6
– Audio cable unplugged
7
– Video signal lost for signal routed
as a result of a manual override
action
8
– CEC monitor standby command
time_out
– Timeout in seconds
0 - 60000
Get the Disable 5V on video
output if no input signal
detected timeout:
#AV-SW-TIMEOUT?
4
<CR>
BUILD-DATE?
Get device build date.
COMMAND
#BUILD-DATE?
<CR>
FEEDBACK
~nn@BUILD-DATE
date
,
time
<CR><LF>
date
– Format: YYYY/MM/DD where
YYYY = Year
MM = Month
DD = Day
time
– Format: hh:mm:ss where
hh = hours
mm = minutes
ss = seconds
Get the device build date:
#BUILD-DATE?
<CR>
DRAFT