74
VP-774 - The VP-774 RS-232 Communication Protocol
1st
Level
2nd Level
3rd Level
4th Level
Range
Func. Note
Factory Reset
0:1
770
Follow OSD
instructions.
Self-clearing.
12.3
Protocol Table: Mimicking Remote and Front Panel
Buttons
The keystroke codes operate in the following way:
SET command third param =0,
Syntax example: "#Y 0,10,0<CR>" => MENU keystroke
GET command for keystrokes will return ERR
The following table defines the keystroke function codes:
Button
Keystroke
Code
Button
Keystroke
Code
Button
Keystroke
Code
MENU
10
CH1_VGA1
21
CH2_HDMI1
32
ENTER
11
CH1_VGA2
22
CH2_HDMI2
33
MINUS
12
CH1_HDMI1
23
CH2_HDMI4
34
PLUS
13
CH1_HDMI2
24
CH2_DP
35
RESET
14
CH1_HDMI4
25
CH2_SDI
36
PIP
15
CH1_DP
26
MUTE
37
BLANK
16
CH1_SDI
27
POWER
38
FREEZE
17
CH2_CV1
28
LEFT
39
LOCK
18
CH2_HDMI3
29
RIGHT
40
CH1_CV1
19
CH2_VGA1
30
DUMMY
99
CH1_HDMI3
20
CH2_VGA2
31
12.4
The Protocol 3000 Common Operation Commands
The following table lists the protocol 3000 commands:
Operation commands
Command
Syntax
Response
Lock front panel
LOCK-FP
LOCK-MODE
LOCK-FP
LOCK-MODE
RESULT
Get front panel
locking state
LOCK-FP?
LOCK-FP
LOCK-MODE
Parameters Description:
LOCK-MODE
= Front panel locking state:
"0" or "off" to unlock front panel buttons.
"1" or "on" to lock front panel buttons.