VP-444
– RS-232/Ethernet (UDP) Communication Protocol
50
SCLR-PCAUTO
Function
Permission
Transparency
Set:
SCLR-PCAUTO
End User
Public
Get:
-
-
-
Description
Syntax
Set:
Set PC auto sync of scaler
#SCLR-PCAUTO
␠
P1,P2
␍
Get:
-
-
Response
~
nn
@SCLR-PCAUTO
␠
P1,P2….
␍␊
Parameters
P1 (Scaler number)
–1=Scaler
P2 (Off/On)
–1=Yes
Response Triggers
The auto adjust feature is implemented every time P2 is set to “Yes”
Notes
Trigger the Auto Adjust feature of PC input
SCLR-AUDIO-DELAY
Function
Permission
Transparency
Set:
SCLR-AUDIO-DELAY
End User
Public
Get:
SCLR-AUDIO-DELAY?
End User
Public
Description
Syntax
Set:
Set the scaler audio delay
#SCLR-AUDIO-DELAY
␠
P1,P2
␍
Get:
Get the scaler audio delay
#SCLR-AUDIO-DELAY?
␠
P1
␍
Response
Set / Get: ~
nn
@SCLR-AUDIO-DELAY
␠
P1,P2
␍␊
Parameters
P1 (Audio output number)
–1=Scaler
P2 (Level selection)
– 0=Off; 1=40ms; 2=110ms; 3=150ms
Response triggers
Response is sent to the com port from which the Set (before execution) / Get command was received
After execution, response is sent to all com ports if CMD-NAME was set any other external control device
(button press, device menu and similar) or genlock status was changed
Notes
Sets the audio delay for the selected audio output