3.1 

About the Power Connect Feature 

The Power Connect feature applies as long as the cable can carry power. 

This feature is available when using STP cable and the distance does not 

exceed 50m on standard CAT 5 cable. For longer distances, heavy gauge 

cable should be used

1

.

 

For units which are connected via RJ-45 connectors, 

make sure that the shield of the STP cable is connected to the metal casing 

of the connectors on both ends of the cable. For units which are connected 

via terminal block connectors, the shield of the STP cable must be 

connected to a ground terminal on the units at both ends (use the ground 

terminal of the power supply connection if necessary). 
For a CAT 5 cable exceeding a distance of 50m, separate power supplies 

should be connected to the transmitter and to the receiver simultaneously.

 

3.2 

Shielded Twisted Pair (STP) / Unshielded Twisted Pair (UTP) 

We recommend that you use Shielded Twisted Pair (STP) cable. There are 

different levels of STP cable available, and we advise you to use the best 

quality STP cable that you can afford. Our non-skew-free cable, Kramer 

BC-STP

 is intended for analog signals where skewing is not an issue. For 

cases where there is skewing, our UTP skew-free cable, Kramer 

BC-XTP

may be used. Bear in mind, though, that we advise using STP cables where 

possible, since the compliance to electromagnetic interference was tested 

using those cables. 
Although Unshielded Twisted Pair (UTP) cable might be preferred for long 

range applications, the UTP cable should be installed far away from electric 

cables, motors and so on, which are prone to create electrical interference.  

However, since the use of UTP cable might cause inconformity to 

electromagnetic standards, Kramer does not commit to meeting the standard 

with UTP cable. 

 

 

 

 

 

 

 

 

 

 

                                                       

 

1 CAT 5 cable is still suitable for the video/audio transmission, but not for feeding the power at these distances 

Содержание VP-300THD

Страница 1: ...Kramer Electronics Ltd Preliminary USER MANUAL Model VP 300THD 1 2 XGA HD DA CAT 5 Transmitter...

Страница 2: ...5 LINE IN LINE OUT RJ 45 Connectors 8 6 Technical Specifications 8 Figures Figure 1 VP 300THD 1 2 XGA HD DA CAT 5 Transmitter 5 Figure 2 VP 300THD 1 2 XGA HD DA CAT 5 Transmitter Underside 6 Figure 3...

Страница 3: ...ludes the following items The VP 300THD 1 2 XGA HD DA CAT 5 Transmitter Power supply 12V DC This user manual2 2 Getting Started We recommend that you Unpack the equipment carefully and save the origin...

Страница 4: ...ide switches Step 2 Connect the power Step 3 If required 1 1 2 2 3 3 3 Connect the input Connect the outputs Connect the CAT 5 cable between the transmitter VP 300THD and the receiver TP 120 Connect t...

Страница 5: ...ol A resolution of up to WUXGA and 1080p A transmission range of more than 300 feet more than 100 meters The Power Connect feature see section 3 1 12V DC power To achieve the best performance Use only...

Страница 6: ...2 Shielded Twisted Pair STP Unshielded Twisted Pair UTP We recommend that you use Shielded Twisted Pair STP cable There are different levels of STP cable available and we advise you to use the best qu...

Страница 7: ...15 pin HD Connector Connect to the XGA acceptor 2 3 LINE OUT RJ 45 Connector Connects to1 the LINE IN RJ 45 connector on the TP 120 XGA Line Receiver2 4 12V DC 12V DC connector for powering the unit...

Страница 8: ...F 5 Connecting the VP 300THD You can use the VP 300THD and for example the TP 120 to configure an XGA HD DA CAT 5 Transmitter and Receiver system To connect the VP 300THD with the TP 120 as the exampl...

Страница 9: ...to the mains electricity socket 5 On the VP 300THD if required Set the ID BIT switch to ON Set the VS and HS switches1 on the underside 6 On the TP 120 if required Adjust2 the video output signal leve...

Страница 10: ...chnical Specifications This section includes the technical specifications1 of the VP 300THD Table 4 Technical Specifications of the VP 300THD with 30m CAT 5 cable INPUT 1 XGA on an 15 pin HD connector...

Страница 11: ...ofnature ii Product modification orfailureto followinstructions supplied with theproduct iii Repairorattemptedrepairby anyonenot authorized byKramer iv Anyshipment oftheproduct claims must bepresented...

Страница 12: ...st information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions comments and feed...

Отзывы: