background image

 

 
 

 

KRAMER ELECTRONICS LTD.

                                                                          11                    

8 TROUBLESHOOTING 

 

NOTES 

1. 

Please note that if the output signal is disturbed or interrupted by very 
strong external electromagnetic interference, it should return and stabilize 
when such interference ends. If not, disconnect power from the machine and 
reconnect again to reset the machine.   

2. 

If the recommended actions still do not result in satisfactory operation, 
please consult your KRAMER Dealer. 

8.1 

Power and Indicators 

Problem Remedy 

 

No Power 

1. 

Confirm that power connections are secured at the 

machine and at the receptacle. Make sure the 
receptacle is active, outputting the proper voltage. 

2. 

If there is still no power use a Philips screwdriver, to 

remove two screws on both sides of the machine and 
release the panel (e.g. VP-200xl). 

3. 

Locate the fuse holder located inside your machine. 

Confirm that the fuse is good by looking for the wire 
connected between the ends of the fuse. If this wire is 
broken, replace the fuse with another, with the same 
rating. 

4. 

Install the machine's cover by tightening its Philips 

screws. 

 

8.2 VGA/XGA 

Signal 

Problem Remedy 

 

No VGA/XGA 
the output 
device 

1. 

Confirm that your source and output devices are 

powered on and connected properly. The input of your 
machine should be of an identical signal format at the 
output of your source.  

2. 

Confirm that any other device in the signal path have 

the proper input and/or output selected. 

3. 

Use a VP-800 together with a known working 

monitor to help trace faulty cables and equipment.   

 

Содержание VP-200XL

Страница 1: ...KRAMER ELECTRONICS LTD Kramer Electronics Ltd USER MANUAL 1 2 VGA XGA Distributor Model VP 200xl IMPORTANT Before proceeding please read paragraph entitled Unpacking and Contents...

Страница 2: ...r VP 200xl Distributor 6 5 INSTALLATION 8 5 1 Rack Mounting 8 6 CONNECTING TO VGA XGA DEVICES 8 6 1 TYPICAL APPLICATION 8 6 2 HANDLING SIGNAL LOSSES 9 6 3 Adding more outputs 10 6 4 Adding more inputs...

Страница 3: ...upling VGA XGA Distribution Amplifiers are used to distribute one source to several acceptors wide screen projectors format converters etc for simultaneous recording or monitoring of one source with n...

Страница 4: ...and transmit modern high resolution graphics amplifiers with bandwidths of 300 MHz and more are needed Those amplifiers besides the enormous bandwidth they handle need to be linear to have very low di...

Страница 5: ...fecting the quality of results when signals are transmitted from a source to an acceptor Connection cables Low quality cables are susceptible to interference they degrade signal quality due to poor ma...

Страница 6: ...ze machines in a standard 1U or 3U rack space One or more machines may be installed on each adapter VP 211 2x1 Automatic VGA Audio Switcher can be serially inserted between the VGA audio switcher and...

Страница 7: ...ion describes the controls and connections of your distributor Understanding the controls and connections helps you realize the full power of your machine 4 1 Getting to Know Your VP 200xl Distributor...

Страница 8: ...ion 1 INPUT HD 15 connector VGA XGA input 2 OUTPUT 1 HD 15 connector VGA XGA output 3 OUTPUT 2 HD 15 connector VGA XGA output 4 LEVEL Control Knob Adjusting VGA XGA signal output level 5 EQ Control Kn...

Страница 9: ...or the RK T3 optional adapter 3U rack space for mounting up to eight machines 5 2 Connecting TO VGA XGA Devices VGA XGA sources and output devices such as monitors projectors or recorders may be conne...

Страница 10: ...able compensation is needed Even with the best available compound cables several thin cables in one sleeve at SXGA resolution 1280x1024 or UXGA resolution over five meters there will be apparent signa...

Страница 11: ...e of Kramer s VGA XGA switchers may be installed in front of the VP 200xl Some suitable machines are the VP 201 2 inputs VP 32xl 3 inputs VP 61xl 6 inputs etc 7 SPECIFICATIONS INPUT Analog Red Green B...

Страница 12: ...no power use a Philips screwdriver to remove two screws on both sides of the machine and release the panel e g VP 200xl 3 Locate the fuse holder located inside your machine Confirm that the fuse is g...

Страница 13: ...erconnected equipment is connected to the same phase of power if possible 4 Remove equipment connected to that phase that may introduce noise such as motors generators etc 5 Disconnect all interconnec...

Страница 14: ...ity of the Kramer dealer from whom the product was purchased 3 Shipping charges HOW YOU CAN GET WARRANTY SERVICE 1 To obtain service on you product you must take or ship it prepaid to any authorized K...

Страница 15: ...tibility EMC generic emission standard Part 1 Residential commercial and light industry EN 50082 Electromagnetic compatibility EMC generic immunity standard Part 1 Residential commercial and light ind...

Страница 16: ...or the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions commen...

Отзывы: