Kramer Electronics Ltd.
VIA Connect
– For Web Administrator: Configuring Settings – Gateway Dashboard
43
For Web Administrator:
Configuring Settings
–
Gateway
Dashboard
VIA Connect
enables users with Web Administrator access to configure LAN settings and
access system controls from the gateway dashboard.
Logging in to Gateway Dashboard Settings
The gateway dashboard Settings can be accessed by connecting a mouse and keyboard
directly to the VIA gateway unit (see
For Installer: Connecting VIA Connect
) or
through an external device that is logged in to the meeting and in Collaboration mode
(see
To log in to the Gateway Dashboard Settings:
1. Click the VIA icon in the lower left of the main display.
The gateway dashboard appears.
2. Click
Settings
.
The login window appears.
3. Type an administrator user name and password (default user name = su, default
password = supass).
The Settings screen appears with the LAN Settings tab open.
Changing LAN Settings
VIA Connect
enables you to change the IP address, DNS server and default gateway of your
VIA Connect
unit.
The default IP setting is DHCP that assigns an automatic IP address to your unit. This
enables easy plug and play setup when connecting your
VIA Connect
to the network. The
following explains how to change a static IP address.
When changing these settings, make sure they are correct. Incorrect values can cause a loss
of communication.
To change the LAN settings:
1. On the gateway dashboard Settings Screen, under IP Configuration, select
Static
.
2. Enter, as required, the Host Name, IP Address, Subnet Mask, Default Gateway,
DNS Server.
3. Click
Apply
.