Serial Control of the VA-8xl or VA-16xl
7
3. Press the same CHANNEL SELECTOR button again.
The memory stores the chosen setup number. As confirmation, for a few
seconds, “YES” appears in the LEFT/dB 7-segment LED Display and the
setup number appears in the RIGHT /dB 7-segment LED Display.
Note:
•
Saving a setup to an already allocated setup number, overwrites the
previous setup
•
To cancel, press the LEFT or RIGHT button
To recall a setting, via the front panel buttons, do the following:
1. When the 7-segment LED Displays are dimmed, press the UP button.
The abbreviation “rCL” (recall) appears in the LEFT/dB 7-segment LED
Display.
2. Press the appropriate CHANNEL SELECTOR button.
The abbreviation “rCL” (recall) appears in the LEFT/dB 7-segment LED
Display and the number of that CHANNEL SELECTOR button appears in
the RIGHT /dB 7-segment LED Display.
3. Press the same CHANNEL SELECTOR button again.
The memory recalls the setup. As confirmation, for a few seconds, “YES”
appears in the LEFT/dB 7-segment LED Display and the setup number
appears in the RIGHT /dB 7-segment LED Display.
If no setting is stored in the non-volatile memory with that setup #, “NO”
appears in the LEFT/dB 7-segment LED Display and the setup number
appears in the RIGHT /dB 7-segment LED Display.
Note:
•
Recalling a setup implements the amplifier gain or the attenuation
immediately
6 Serial Control of the VA-8xl or VA-16xl
You can control a single VA-8xl or VA-16xl unit (see section
6.1) or
configure up to a 240 channel balanced stereo audio amplifier, using 15
VA-16xl units via RS-485 or RS-232 (see section
6.2).