background image

 

TP-410 – 

 

Introduction

 

 

Introduction 

Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been 

providing a world of unique, creative, and affordable solutions to the vast range of 

problems that confront video, audio, presentation, and broadcasting professionals 

on a daily basis. In recent years, we have redesigned and upgraded most of our 

line, making the best even better!  

Our 1,000-plus different models now appear in 11 groups that are clearly defined 

by function: GROUP 1: Distribution Amplifiers; GROUP 2: Switchers and Routers; 

GROUP 3: Control Systems; GROUP 4: Format/Standards Converters; GROUP 5: 

Range Extenders and Repeaters; GROUP 6: Specialty AV Products; GROUP 7: 

Scan Converters and Scalers; GROUP 8: Cables and Connectors; GROUP 9: 

Room Connectivity; GROUP 10: Accessories and Rack Adapters and GROUP 11: 

Sierra Video Products. 

Congratulations on purchasing your Kramer 

TP-410

 UXGA-Audio-RS-232 Line 

Transmitter / DA. This product, which incorporates HDMI™ technology, is ideal for: 

 

Transmission of video, audio and RS-232 signals for extended distances 

over standard STP/UTP cables 

 

Multimedia and presentation source and acceptor selection 

Содержание TP-410

Страница 1: ...KRAMER ELECTRONICS LTD USER MANUAL MODEL TP 410 UXGA Audio RS 232 Line Transmitter DA P N 2900 000733 Rev 3...

Страница 2: ......

Страница 3: ...Wiring the CAT 5 LINE IN LINE OUT RJ 45 Connectors 22 9 Acquiring the EDID 23 10 Flash Memory Upgrade 24 11 Technical Specifications 25 11 1 Communication Parameters 26 12 Default EDID 27 13 Kramer Co...

Страница 4: ...tion GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Routers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP...

Страница 5: ...als application programs and to check if firmware upgrades are available where appropriate 2 1 Achieving the Best Performance To achieve the best performance Use only good quality connection cables to...

Страница 6: ...audio and RS 232 Selectable unbalanced stereo or digital audio S PDIF input signals One local output on a 15 pin HD computer graphics video connector One digital audio S PDIF local output on an RCA co...

Страница 7: ...ing our Unshielded Twisted Pair UTP skew free cable Kramer BC XTP may be advantageous and UTP cable might also be preferable for long range applications In any event when using UTP cable it is advisab...

Страница 8: ...s when a local analog audio input is selected 4 SOURCE LEDs TP Lights when a UXGA Audio RS 232 via twisted pair input is selected 5 LOCAL Lights when the local UXGA Audio RS 232 input is selected 6 IN...

Страница 9: ...lt from using long cables due to the effects of stray capacitance for example sometimes leading to a loss of sharpness in high resolution signals Use a screwdriver to carefully rotate the trimmer adju...

Страница 10: ...en turn it ON while pressing the FACTORY RESET button The unit will power up and load its memory with the following factory default definitions default Ethernet settings IP address 192 168 1 39 TCP po...

Страница 11: ...8 TP 410 Installing in a Rack 4 Installing in a Rack This section provides instructions for rack mounting the unit...

Страница 12: ...balanced stereo audio source for example the audio source of the computer to the AUDIO INPUT 3 5mm mini jack connector You can also connect a digital audio source to the S PDIF RCA connector and selec...

Страница 13: ...see Section 5 3 and Section 6 Ethernet connector see Section 5 4 8 Set the DIP switches see Section 7 9 Connect the power cord not shown in Figure 3 We recommend that you use only the power cord that...

Страница 14: ...Connect the RS 232 G pin on the TP 410 to pin 5 9 pin D sub on the RS 232 device 1 2 6 3 7 4 8 5 GND Tx Rx 9 Figure 4 RS 232 Pinout 5 3 Connecting to the TP 410 via an RS 485 Connection You can opera...

Страница 15: ...g a crossover cable see Section 5 4 1 for direct connection to the PC or a straight through cable see 5 4 2 Section 5 4 1 Connecting the ETHERNET Port directly to a PC Crossover Cable for connection v...

Страница 16: ...CP IP Properties Window 5 4 2 Connecting the ETHERNET Port via a Network Hub Straight Through Cable You can connect the Ethernet port of the TP 410 to the Ethernet port on a network hub or network rou...

Страница 17: ...tches to their previous position and then turn the power Off and On again The latest version of K UPLOAD and installation instructions can be downloaded from the Kramer Web site at www kramerelectroni...

Страница 18: ...control data This applies to a single unit or multiple cascaded units supplying up to 150 destination control points 6 1 The Local Mode In the local mode you can configure and distribute the control d...

Страница 19: ...a computer graphics source is connected via a transmitter to the TP IN RJ 45 connector Outputs 1 4 and 5 are connected to TP 126 units The system is controlled by a laptop via the Ethernet The machin...

Страница 20: ...485 bus with control from a PC or serial controller To connect up to 15 TP 410 units via RS 485 see Figure 11 1 Connect the RS 485 terminal block of the first TP 410 to the RS 485 terminal block of t...

Страница 21: ...18 TP 410 Configuration and Distribution of Control Data Figure 11 Connecting Multiple TP 410 Units via RS 485...

Страница 22: ...achine DIP switches 1 2 3 and 4 set the machine number according to the table below Figure 12 The Address DIP switches Add DIP 1 DIP 2 DIP 3 DIP 4 Add DIP 1 DIP 2 DIP 3 DIP 4 1 OFF OFF OFF OFF 9 OFF O...

Страница 23: ...on of K UPLOAD and installation instructions can be downloaded from the Kramer Web site at www kramerelectronics com 7 2 Setting the RS 232 RS 485 Baud Rate DIP switches DIP switches 5 6 and 7 set the...

Страница 24: ...the RS 485 Bus Termination The DIP switch sets the RS 485 bus termination Only the first and last physical devices on the RS 485 bus must be terminated set to ON all other devices must be set to OFF F...

Страница 25: ...out using a straight pin to pin cable with RJ 45 connectors Note that the cable Ground shielding must be connected soldered to the connector shield EIA TIA 568B Figure 15 CAT 5 PINOUT PIN Wire Color 1...

Страница 26: ...nd 15 of the VGA connector It is essential that the cable used for capturing the EDID passes all 15 pins 2 Connect the display power 3 On the TP 410 connect the power 4 Press the EDID CAPTURE button 5...

Страница 27: ...UPLOAD set DIP switches 1 to 4 to ON ON ON ON ON turn the power Off and then back On After completion of flash memory upgrade set DIP switches 1 to 4 to their previous position and reset the power The...

Страница 28: ...O 2 3Vpp CONTROLS RS 232 RS 485 Ethernet program control Source control from front panel TP IN level and equalization from rear panel SERIAL BAUD RATE Up to 19200 bps SERIAL MODE Full duplex BANDWIDTH...

Страница 29: ...HEX Ethernet Default Settings Factory Reset Settings IP Address 192 168 1 39 Power cycle the unit while pressing the Factory Reset button located on the rear panel of the unit The unit will reset to i...

Страница 30: ...ne Timing characteristics Range limits Not available GTF standard Not supported Additional descriptors None Preferred timing Yes Native preferred timing 1024x768p at 60Hz 4 3 Modeline 1024x768 65 000...

Страница 31: ...I0 INPUT When switching ie instruction codes 1 and 2 the INPUT 7 bits is set as the input number which is to be switched Similarly if switching is done via the machine s front panel then these bits ar...

Страница 32: ...ws The same command and output codes as were sent are returned and the input is assigned the value of the parameter that was read The reply is per the definitions in command 44 NOTE 4 At initial power...

Страница 33: ......

Страница 34: ...P N 2 9 0 0 0 0 0 7 3 3 QS Rev 3...

Отзывы: