KRAMER: SIMPLE CREATIVE TECHNOLOGY
Default Communication Parameters
24
11
Default Communication Parameters
Table 10: Default Communication Parameters
Protocol 3000 (Default)
Baud Rate:
115,200
Data Bits:
8
Stop Bits:
1
Parity:
None
Command Format:
ASCII
Example (Output 1 to Input 1):
#AV 1>1<CR>
Ethernet
Default Settings
Reset Settings
IP Address: 192.168.1.39
Subnet Mask:
Gateway:
Power cycle the unit while holding in the Factory Reset
button, located on the rear panel of the unit
TCP Port #: 5000
UDP Port #: 50000
12
Communication Protocol 3000
The Protocol 3000
1
is an RS-232/Ethernet communication protocol that enables you to
control the device from any standard terminal software (for example, Windows®
HyperTerminal Application).
12.1
Protocol 3000 Syntax
Host message format:
Start
Address (optional)
Body
Delimiter
#
Destination_id
@
message
CR
Simple command (commands string with only one command without addressing):
start
body
delimiter
#
Command SP Parameter_1,Parameter_2,…
CR
Commands string (formal syntax with commands concatenation and addressing):
#
Address
@
Command_1
Parameter1_1
,
Parameter1_2
,…
|
Command_
2
Parameter2_1
,
Parameter2_2,
…
|
Command_3 Parameter3_1
,
Parameter3_2
,…
|…
CR
1 VER-0.1