Firmware Upgrade
19
Figure 7: Goal Screen
2. Click the
Open…
button to select the new firmware hex file
1
.
3. Click the
Options…
button, select the
Inverted
2
check box in the
Reset
Polarity
area and Click
OK
.
4. In the
Action
area, select
Erase then Program
.
5. Click the
START
button.
The software erases and then programs flash memory.
Upon Completion of the operation, the System Status Window displays:
“
Erase and program completed successfully
” (see Figure 8).
Figure 8: System Status Screen
6. Exit the programmer software.
7. Disconnect the power on the
PIP-300
.
8. Release the PROG. (IN) button.
9. Connect the power on the
PIP-300
.
1 Located in the C:\Program Files\KramerFlash folder
2 In some models you need to select the Normal check box