background image

 

 

 

 

 

Feature 

Function 

Port 1/2 I/O 3-pin Terminal Block 

Terminal block ports 1 and 2 connect to two GPIO ports or two Relays each 

Port 3/4 I/O 3-pin Terminal Block 

Terminal block ports 3 and 4 connect to one bidirectional RS-232 port (or RS-485, port 3 only) 
or two IR outputs each 

10 

RESET Button 

Press and hold while cycling the device power to reset to factory default parameters 

11 

ID 

Press to broadcast ID message for auto-discovery of the device 

12 

LAN/POE RJ-45 Connector 

Connects to a PoE source (Power over Ethernet) for powering and an IP client or other 
controller, either directly or via a LAN 

13 

SERVICE Mini USB Connector 

Connects to a USB power source for powering and to a PC for a local firmware upgrade  

14 

5V DC Connector   

For extra power resiliency, connect to the 5V DC power supply, center pin positive.  
Not needed when the device is supplied power by PoE or a USB power source 

 

FC-54P Function Table 

Port IO 

Function 

Terminal Block Connections 

IO Port 
Default 

TCP Default 
Port [P1/P2] 

Blue Activity LED Pair 

Comment 

P1 

P2 

GPIO 

Ground 

IO

1

 

IO

2

 

Digital In  

x 2 

5000 

ON when IO 

ports are active 

GPIO Analog in & Digital 

out via Web 

Relay 

Common 

NO

1

 

NO

2

 

Normally  

Open x 2 

5000 

ON when Relay 

ports are active 

 

RS-232 

Ground 

Rx 

Tx 

9600,8,N,1 

5001/2 

Flashes when port is  

transmitting & receiving 

data 

Other serial configurations 

via Web, including RS-485 

for Port 3 

IR 

Ground 

IR

1

 

IR

2

 

 

5000 

ON when ports are 

transmitting IR data 

 

Key: 

P1 / P2 

– Port 1 / Port 2 

IO

/ IO

2

 

– GPIO Port 1 / GPIO Port 2 

NO

1

/

NO

– Normally open Port 1 / Normally open Port  2 

Tx 

– Transmit, Rx– Receive; 9600, 8, N, 1 – 9600 baud, 8-bits, no parity, 1 stop bit 

IR

/ IR

2

 

– IR Port 1 / IR Port 2 

 

Отзывы: