background image

EVAP.

EVAP.

SIZE

SIZE

QTY.

PART NO.

V0LTS

WATTS QTY.

PART NO.

VOLTS WATTS

LPE - 6

LPE - 4

35-41-46

38

1

206240-06

230

500

1

200172-42

230

500

63-71

1

206240-07

230

800

1

200172-43

230

800

92

70-86

1

206240-08

230

1000

1

200172-44

230

1000

120-138

106

1

206240-09

230

1500

1

200172-45

230

1500

162-184

142

1

206240-10

230

2000

1

200172-46

230

2000

220

182

1

206240-11

230

2500

1

200172-47

230

2500

240-265

214

1

206240-12

230

3000

1

200172-48

230

3000

(coil heaters)

CSE - 6

MSE - 4

( _

_ _ )

( _

 _ _ )

130-150

105-140

3

206240-022

240

1693

3

206240-021

460

1555

185-270-320

175-230-325

3

206240-004

240

2458

3

206240-020

460

2258

460-520

390-510

3

206240-005

240

3538

3

206240-019

460

3249

CED - 6

KED - 4

450-620

400-550

12

113100

115

800

2

113095

230

725

850-1070

750-950

12

113101

115

1150

2

113096

230

660

1360

1200

26

113102

115

1070

4

113097

115

540

1800

1600

26

113103

115

1400

4

113098

115

700

LVE

65

2

205221020

230

1970

105

2

205221021

230

2980

140-150

2

200172049

230

2980

180-215-275

2

200172024

230

1550

(PLUS) 

 

Ä

2

200172028

230

2480

371

4

200172028

230

2480

HSE - 6

HSE -4

55-63-71

50-60-66

2

208579-001

230

1037

79-91-103

74-86-94

2

208579-002

230

1490

125-143

116-130

2

208579-003

230

1943

163-219

144-174

2

208579-003

230

1943

NOTE:

KRAMER

  

   14230 Lockridge Boulevard, Georgia  30014    Tel. 770-788-5800    Fax. 770-788-5820

HEATER REPLACEMENT GUIDE FOR KRAMER ELECTRIC DEFROST EVAPORATORS

COIL HEATER

RATINGS

DRAIN PAN HEATER

RATINGS

230 volt units

460 volt units

Содержание CED

Страница 1: ...812 SEPTEMBER 1999 NEW KRAMER ELECTRIC DEFROST EVAPORATORS LPE LVE MSE CSE HSE CED KED INSTALLATION START UP AND MAINTENANCE INSTRUCTIONS 14230 Lochridge Blvd Covington Georgia 30014 770 778 5800 Fax...

Страница 2: ...MSE models are recommended for room temperatures to 20 F model CED and KED to 30 F and model HSE to 10 F Model CED and KED are available with D type direct drive fans as standard or an optional PP typ...

Страница 3: ...uld be selected from the valve manufacturers literature If liquid subcooling is present be sure to use the correction factor to determine the correct size valve Avoid oversizing the valve which can ca...

Страница 4: ...ainst a wall or directly on the floor Always leave 1 or more inches of air space along side walls and each end wall space should be equivalent to the evaporator height or more Do not locate evaporator...

Страница 5: ...not to scale No doors at side or back of evaporators Back wall H H 2 x H H Side Evaporator wall Air Air 5 x H Side Alternate wall Door location See Table above for H dimension Door Front wall 5 EVAPO...

Страница 6: ...1 3 8 1 5 8 1 3 8 1 5 8 2 1 8 1 2 1 2 5 8 60000 75000 1 1 8 1 3 8 1 3 8 1 3 8 1 3 8 1 5 8 1 3 8 1 3 8 1 5 8 1 3 8 1 5 8 1 5 8 1 5 8 1 5 8 2 1 8 1 2 5 8 5 8 75000 90000 1 3 8 1 3 8 1 5 8 1 3 8 1 5 8 1...

Страница 7: ...1 3 8 1 3 8 1 3 8 1 3 8 1 5 8 1 2 1 2 5 8 48000 60000 1 1 8 1 3 8 1 3 8 1 1 8 1 3 8 1 5 8 1 3 8 1 5 8 1 5 8 1 3 8 1 5 8 1 5 8 1 3 8 1 5 8 1 5 8 1 2 5 8 5 8 60000 75000 1 1 8 1 3 8 1 5 8 1 3 8 1 5 8 1...

Страница 8: ...n shipment Spin each fan blade to be sure it turns freely FIELD WIRING Terminal Block H1 H2 H3 3 N X 4 M3 HEATER SAFETY DEFROST TERMINATION Brown Yellow MOTORS and CAPACITORS FAN DELAY Brown Use only...

Страница 9: ...edium frost load air circulation is still good and coils defrost best Defrosting with a very light frost load can cause steaming Allowing a coil to become heavily frosted can reduce air circulation an...

Страница 10: ...iver Pressure_________PSI Evaporator Frost Load Light o Medium o Heavy o ___________________ Time since last defrost_____hours Timer set ____ defrost per day _____ minute Fail Safe DEFROST Check Heate...

Страница 11: ...006009 30 202136007 Defrost Termination Std 103079010 103079010 103079010 Adjustable DTFD is Fan Delay Std 103079009 103079009 103079009 standard on CED KED Adjustable DTFD Optional 204464037 20446403...

Страница 12: ...510 3 206240 005 240 3538 3 206240 019 460 3249 CED 6 KED 4 450 620 400 550 12 113100 115 800 2 113095 230 725 850 1070 750 950 12 113101 115 1150 2 113096 230 660 1360 1200 26 113102 115 1070 4 1130...

Отзывы: