Step 4:  Connect the inputs and outputs 

Each 

ASPEN-32UFX 

port can be defined as an input or an output, enabling flexible configurations such as 1x31distribution 

amplifiers, 31x1 routers or any other possible input-output combination. By default, the 

ASPEN-32UFX 

is set to operate as a 16x16 

router: PORT 1 to PORT 16 as the inputs, and PORT 17 to PORT 32 as the outputs. 

Always switch OFF the power on each device before connecting it to your 

ASPEN-32UFX

Optionally, daisy-chain the 

ASPEN-32UFX

 by looping the genlock source to the next machine. 

 

 

 

 

 

RJ-45 Pinout: 

 

 

 

 

PIN EIA /TIA 568B 

PIN 

Wire Color 

Orange / White 

Orange 

Green / White 

Blue 

Blue / White 

Green 

Brown / White 

Brown 

 
 
 

Step 5:  Connect the power 

Connect the 12V DC power supply to 

ASPEN-32UFX

 and plug it into the mains electricity. You can add a second power supply (not 

supplied in the package) for backup.  

 

Safety Instructions 

 

Caution: 

There are no operator serviceable parts inside the unit.

 

Warning: 

Use only the Kramer Electronics power supply that is provided with the unit. 

Warning: 

Disconnect the power and unplug the unit from the wall before installing.  

Se

www.KramerAV.com

 for updated safety information. 

 

 