![KRAL EKL 11 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/kral/ekl-11/ekl-11_operation-instructions-manual_2000374014.webp)
6 Transportation, storage
5.10 Heating system (optional)
5.10 Heating system (optional)
5.10.1
Possible types of heating
The pump station can optionally be equipped with a heating system. The manufacturer recommends a
heating system at high-viscosity pumped liquids that do not flow sufficiently if not heated. This can res-
ult in excessive wattage or in problems arising through cavitation or sealing.
Possible types of heating:
o
Electrical heating system pump
o
Electrical heating system strainer
5.10.2
Electrical heating system
The output of the heating elements corresponds to the radiation and convection losses of the station in
the required temperature range so that overheating is not possible.
Electrical heating system pump
Detailed information is provided in the associated operating instructions of the pump.
Electrical heating system strainer
The heating element is inserted into the strainer chamber and fastened with a special cover. The oil
heated up in the strainer also enters the pump and thus ensures reliable starting.
Parameter
Unit
Value
Voltage
[V]
230
Heating output
[W]
180
Wire cross-section
[mm
2
]
2 x 1
Tab. 10: Operating data
6 Transportation, storage
6.1 Dangers during transportation
The following safety instructions must be observed
o
Have all work only carried out by authorized qualified personnel.
o
A crane operator and transport personnel are required for transportation (2 persons).
o
Use intact and correctly dimensioned hoisting equipment.
o
Ensure that the means of transport is in a flawless state.
o
Ensure that the centre of gravity of the load is taken into consideration.
o
Do not stand under raised loads.
o
Cordon off the danger zone and ensure that unauthorized persons cannot enter the danger zone.
6.2 Dangers during storage
The following safety instructions must be observed:
o
Observe the storage conditions.
14
OIK 10en-GB Edition 2021-06
Operation instructions