11 Menu description
11.4 Menu 1: Display
Menu item
Description
0.09 Pulse output pulse
width setting
This function is only possible after entry of the system password 1919
2.01 Setting Enable
Password
.
Increasing the pulse width always involves a reduction in the maximum output frequency (e.g. pulse
width 200 ms – maximum frequency 2.5 Hz).
Note:
After the setting has been changed, the electronic unit has to be restarted.
11.4 Menu 1: Display
o
Display of measured values
o
Resetting the sum
o
Setting contrast and background illumination
o Ä
Menu item
Description
1.01 Display
Volumeter A
Shows the current flow in flowmeter A.
1.02 Display
Volumeter A Total
Shows the total values since the last resetting.
Note
:
Total value remains with the following minimum value or maximum value:
o
3 decimal places:
+/-1 999 999.999
o
1 decimal place:
+/-199 999 999.9
Decrease decimal places or change the unit
1.03 Display Reset
Group Error Message
Reset the group error message after eliminating the cause for the activation of the group error mes-
sage.
1.04 Information
Shows serial number, software version and hardware version.
1.05 Setting Display
Brightness
Adjusting the brightness of the display.
1.06 Setting Display
Contrast
Adjusting the contrast of the display.
1.07 Setting select
language
Selection of the language.
1.12 Help on operation
Shows the brief instruction.
11.5 Menu 2: General settings
o
Changing general settings in accordance with the requirements of the measuring task
o
Changes only possible with password
o Ä
Menu item
Description
2.01 Setting Enable
Password
Factory settings:
o
Password:
1000
o
Password protection:
Yes
Yes
o
Password protection is active - no changes is possible
No
o
Password protection is not active - changes are possible
Note:
The pulse width of the pulse input can be changed in
0.09 Pulse output pulse width setting
after en-
tering the system password 1919.
No further changes may be made by the user in menu 0!
Operating instructions
OIE 15en-GB Edition 2020-03
21