NOTICE
During transport and installation, the device must always be held by the
housing and never by the plug.
The device must be installed in such a way that it is not exposed to any
impermissible vibrations.
Hot parts must not be installated since any escaping fluid could ignite.
It must be guaranteed that all lines and connections are tight and no leak-
ages can occur
During operation start-up, the device must be checked for leaks under op-
erating conditions.
The device was tested in the factory before delivery and can be used imme-
diately following installation and connection of the electrical cables.
The space required for the device is specified in the "
The built-in measuring device should also be safely accessible for visual in-
spection at any time during operation.
Depending on the type of connection the device is connected to the system
via a connection plate or connections within the housing.
●
Before installation, the device must be checked for transport damage and
soiling.
●
Any preserving agents must be removed before installation using ben-
zine or solvent.
●
Clean the pipework of dirt, scale, sand, swarf, etc. prior to installation.
Welded pipes in particularly must be pickled or flushed. Cotton waste
must not be used for cleaning.
Gear type flow meter VC 0,025 ... VC 16
BVC0002EN-D0025420002_01 2010-07-05
49