35
KPS-MT40 • Digital multimeter
ENG
Overload protection: 250V dc or 250V ac RMS
4.2.4 Resistance
Range
Resolution
Accuracy
200Ω
0,1Ω
± (0,8% of r3 digits)
2kΩ
1Ω
± (0,8% of r2 digits)
20kΩ
10Ω
200kΩ
100Ω
2MΩ
1kΩ
20MΩ
10Ω
± (1,0% of r2 digits)
200MΩ
0,1MΩ
± (6,0% of r2 digits)
Overload protection: 250V dc or 250V ac RMS
Open circuit voltage: below 700mV.
4.2.4 Diode
Range
Resolution
Resolution
Test environment
Diode test
1V
0,001V
Test current: about 1mA.Open
circuit voltage: about 2.8V.
Display approximation of diode
forward voltage drop.
Protección de sobrecarga: 250V CC o CA RMS
4.2.6 Audible continuity
Range
Description
Test condition
When built-in buzzer sounds,
the resistance to be tested is
not more than 50Ω.
Test current: about 1mA.
Open circuit voltage: about 2.8V