2.  Divide the space volume by 50 cu. ft. to determine the maximum BTU/hr the space can support.  

__________ (Volume of space) 

÷

 50 cu. ft. = (Maximum BTU/hr the space can support)  

Example

:  2560 cu. ft. (volume of space) 

÷

 50 cu. ft. = 51.2 or 51,200 (maximum BTU/hr the space can support)  

3.   Add the BTU/hr of all fuel burning appliances in the space.  

Vent-free heater  

_____________ BTU/hr 

Gas water heater* 

_____________ BTU/hr 

Gas furnace 

_____________ BTU/hr 

Vented gas heater 

_____________ BTU/hr 

Gas heater logs 

_____________ BTU/hr 

Other gas appl  BTU/hr 
Total 

= _____________ BTU/hr 

*Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the 
outdoors.  
 
4.  Compare the maximum BTU/hr the space can support with the actual amount of BTU/hr used.  

__________ BTU/hr (maximum the space can support)  
__________ BTU/hr (actual amount of BTU/hr used).  

Example

: 51,200 BTU/hr (maximum the space can support)  

 

56,000 BTU/hr (actual amount of BTU/hr used)  

The space in the above example is a confined space because the actual BTU/hr used is more than the maximum 
BTU/hr the space can support.  

You must provide additional fresh air. Your options are as follows:  

a)  Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, 

remove  door  to  adjoining  room  or  add  ventilation  grills  between  rooms.  See 

Ventilation  Air  from  inside 

Building,

 page 9. 

b)  Vent room directly to the outdoors. See 

Ventilation Air from Outdoors

, Page 9.  

c)   Install a lower BTU/hr heater if lower BTU/hr size makes room unconfined. If the actual BTU/hr used is less 

than  the  maximum  BTU/hr  the  space  can  support,  the  space  is  an  unconfined  space.  You  will  need  no 
additional fresh air ventilation. 

 

 WARNING:

 If the area in which the heater may be operated is smaller than that defined as an unconfined space 

or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the 
methods described in the 

National Fuel

 

Gas Code, ANSI Z223.1/NFPA 54

, Air for Combustion and Ventilation, or 

applicable local codes. 

 

 

WARNING:

  If  the  area  in  which  the  heater  may  be  operated  does  not  meet  the  required  volume  for  indoor 

combustion  air,  combustion  and  ventilation  air  shall  be  provided  by  one  of  the  methods  described  in  the 
NATIONAL FUEL GAS CODE, ANSI Z223.1/NFPA 54, the INTERNATIONAL FUEL GAS CODE, or applicable 
local codes.

 

 
 
 
 
 
 

Example:  
Gas water heater 

30,000 BTU/hr 

Vent-free heater 

+  26,000 BTU/hr 

Total 

=    56,000 BTU/hr 

Содержание FBD3211R

Страница 1: ...OR LOSS OF LIFE WM FBD3211R 0903 CAUTION FOR YOUR SAFETY This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilat...

Страница 2: ...tallation Failure to follow these instructions may result in a possible fire hazard and will void the warranty PRODUCT SPECIFICATIONS MODEL FBD3211R Input Rating 32 000 BTU Hr 32 000 BTU Hr Gas Type N...

Страница 3: ...AS Natural and Propane LP gases are odorless An odor making agent is added to the gas The odor helps you detect a gas leak However the odor added to the gas can fade Gas may be present even though no...

Страница 4: ...before servicing Only a qualified service person should service and repair heater 10 Operating heater above elevations of 4 500 feet could cause pilot outage 11 To prevent performance problems do not...

Страница 5: ...husetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In the State of Massachusetts unvented pro...

Страница 6: ...ne 1 ounce 30 mL of water for every 1 000 BTUs 3 kw of gas input per hour An unvented room heater is recommended as a supplemental heater a room rather than a primary heat source an entire house In mo...

Страница 7: ...less provisions are provided for adequate combustion and ventilation air Adjoining rooms are connecting only if there are doorless passageways or ventilation grills between them Unusually Tight Constr...

Страница 8: ...fresh air Your options are as follows a Rework worksheet adding the space of an adjoining room If the extra space provides an unconfined space remove door to adjoining room or add ventilation grills...

Страница 9: ...provide two permanent openings one within 12 inches of the ceiling and one within 12 inches of the floor Connect these items directly to the outdoors or spaces open to the outdoors These spaces includ...

Страница 10: ...air exist may cause walls to discolor WARNING Maintain the minimum clearances If you can provide greater clearances from floor ceiling and adjoining side and back walls IMPORTANT Vent free heaters ad...

Страница 11: ...peration Walls and mantels above the firebox may become hot to the touch If installed properly these temperatures meet the requirement of the national product standard Follow all minimum clearances sh...

Страница 12: ...ebox front facing WARNING Do not allow combustible or noncombustible materials to cover any necessary openings like louvered slots WARNING Never modify or cover the louvered slots on the front of the...

Страница 13: ...d equipment shutoff valve with 1 8 in NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA design certified equipment shutoff valve from your dealer WARNING Never co...

Страница 14: ...going into pipe Excess sealant in pipe could result in clogged heater valves CAUTION Use pipe joint sealant that is resistant to gas PROPANE or NG We recommend that you install a sediment trap in a s...

Страница 15: ...ction valve must be locked into the NG position Do not operate heater between locked positions 3 Rotate and close cover over gas selection valve and reinstall screw 4 Remove steel or metal hex plug wi...

Страница 16: ...s forming show a leak 5 Correct all leaks immediately 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3...

Страница 17: ...er The remote receiver operates on four 1 5V AA size batteries It is recommended that ALKALINE batteries be used for longer battery life and maximum microprocessor performance IMPORTANT New or fully c...

Страница 18: ...ogs according to the log installation instructions in this manual Flames contacting logs will create soot Figure 22 Installing Log Set IMPORTANT Make sure log does not cover any burner ports see Figur...

Страница 19: ...ection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions...

Страница 20: ...s heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call...

Страница 21: ...ob should be depressed for about thirty 30 seconds This will allow gas to bleed from the gas system 5 With the control knob pressed in push down and released the ignitor button This will light the pil...

Страница 22: ...de SET Sets temperature in thermo mode LCD Liquid Crystal Display 1 DISPLAY Indicates CURRENT room temperature 2 F OR C Indicates degrees Fahrenheit or Ceisius 3 FLAME Indicates bumer valve in operati...

Страница 23: ...SET key The LCD screen will display the set temperature for 3 seconds Then will flash the set temperature for 3 seconds Then the LCD screen will default to display the room temperature Press the MODE...

Страница 24: ...BURNER FLAME PATTERN Figure 36 shows a correct burner flame pattern Figure 37 shows an incorrect burner flame pattern If pilot flame pattern is incorrect then If burner flame is incorrect turn heater...

Страница 25: ...no greater than 30 PSI You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could da...

Страница 26: ...wrong 2 Ignitor electrode is broken 3 Ignitor electrode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad piezo ignitor 7 Low battery 1 Replace electrod...

Страница 27: ...stomer service 3 Contact your gas supplier Delayed ignition of burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner see Care and Maintenance P...

Страница 28: ...urniture 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax and carpet cleaner or similar products...

Страница 29: ...serial number of your heater How heater was malfunctioning Type of gas used Propane LP or Natural gas NG Purchase date Usually we will ask you to return the defective part to the factory PARTS NOT UN...

Страница 30: ...2D201 Hood 1 6 FB32D303 ODS Inlet Tube 1 7 FB32D302 Outlet Tube 1 8 FB32D301 Inlet Tube 1 9 RV83FI 4 9 DF Regulator 1 10 AF 1110 Valve 1 11 FB32D500 Logs Assembly 1 12 FB32D501B Log 1 1 13 FB32D502B L...

Страница 31: ...31 Printed in China...

Отзывы: