OFF OPERATION 

Press the OFF key and the appliance flame will shut off.  
During this time the LCD screen will show OF (figure 30).  
After 3 seconds the LCD screen will default to display room  
temperature and the wood TEMP will show (figure 31). 
 

THERMOSTAT FUNCTION 
SETTING DESIRED ROOM TEMPERATURE 

This remote control system can control the thermostat 
when the transmitter is in the THERMO mode (The word  

ROOM must be

 

displayed on the screen

). To set the  

THERMO MODE and desired room temperature, Press 
 the MODE key until the LCD screen shows the word  
ROOM. Then the remote is in the thermostatic mode.  
Press and hold the SET key until the desired set temperature 
is reached. (By pressing and holding the set key the LCD screen  
set numbers will increase from 45

°

 to 99

°

 and then restart over at 45

°

)  

Next release the SET key. The LCD screen will display the set temperature for 3 seconds and the LCD screen will 
flash the set temperature for 3 seconds. Then the LCD screen will default to display the room temperature. 

 
TO CHANGE THE SET TEMPERATURE 

Press and hold the SET key until the desired set temperature is reached. (By  
pressing and holding the set key the LCD screen set numbers will increase  
from 45

°

 to 99

°

 then restart over at 45

°

). Next release the SET key. The LCD  

screen will display the set temperature for 3 seconds. Then will flash the set  
temperature for 3 seconds. Then the LCD screen will default to display the room  
temperature. Press the MODE key to disengage the thermo mode. 
The word ROOM on the LCD screen will not show when the thermo is not in  
operation. 

NOTE: 

The highest SET temperature is 99

°

F (32 

°

C) and the lowest temperature  

is 45

°

F (6

°

C). 

 
REMOTE CONTROL OPERATION NOTES: 

The Thermo Feature on the transmitter operates the appliance whenever the ROOM TEMPERATURE varies a certain 
number of degrees from the SET TEMPERATURE. 
This variation is called the 

SWING

 or TEMPERATURE DIFFERENTIAL. The normal operating cycle of an appliance  

may be -4 times per hour depending on how well the room or home is insulated from the cold or drafts. The factory  
setting for the 

swing number

 is 2. This represents a temperature variation of +/-2

°

F (1

°

C) between SET temperature  

and ROOM temperature, which determines when the fireplace will be activated. The transmitter has ON and OFF manual 
functions that are activated by pressing either button on the face of the transmitter. When a button on the transmitter is 
pressed the word ON or OF will appear on the LCD screen to show while the signal is being sent. Upon initial use, there 
may be a delay of three seconds

 

before the remote receiver will respond to the transmitter. This is part of the system

design. 

 

 
 
 
 

Figure 30 

Figure 31 

Figure 32 

Figure 33 

Содержание FBD3211R

Страница 1: ...OR LOSS OF LIFE WM FBD3211R 0903 CAUTION FOR YOUR SAFETY This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilat...

Страница 2: ...tallation Failure to follow these instructions may result in a possible fire hazard and will void the warranty PRODUCT SPECIFICATIONS MODEL FBD3211R Input Rating 32 000 BTU Hr 32 000 BTU Hr Gas Type N...

Страница 3: ...AS Natural and Propane LP gases are odorless An odor making agent is added to the gas The odor helps you detect a gas leak However the odor added to the gas can fade Gas may be present even though no...

Страница 4: ...before servicing Only a qualified service person should service and repair heater 10 Operating heater above elevations of 4 500 feet could cause pilot outage 11 To prevent performance problems do not...

Страница 5: ...husetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In the State of Massachusetts unvented pro...

Страница 6: ...ne 1 ounce 30 mL of water for every 1 000 BTUs 3 kw of gas input per hour An unvented room heater is recommended as a supplemental heater a room rather than a primary heat source an entire house In mo...

Страница 7: ...less provisions are provided for adequate combustion and ventilation air Adjoining rooms are connecting only if there are doorless passageways or ventilation grills between them Unusually Tight Constr...

Страница 8: ...fresh air Your options are as follows a Rework worksheet adding the space of an adjoining room If the extra space provides an unconfined space remove door to adjoining room or add ventilation grills...

Страница 9: ...provide two permanent openings one within 12 inches of the ceiling and one within 12 inches of the floor Connect these items directly to the outdoors or spaces open to the outdoors These spaces includ...

Страница 10: ...air exist may cause walls to discolor WARNING Maintain the minimum clearances If you can provide greater clearances from floor ceiling and adjoining side and back walls IMPORTANT Vent free heaters ad...

Страница 11: ...peration Walls and mantels above the firebox may become hot to the touch If installed properly these temperatures meet the requirement of the national product standard Follow all minimum clearances sh...

Страница 12: ...ebox front facing WARNING Do not allow combustible or noncombustible materials to cover any necessary openings like louvered slots WARNING Never modify or cover the louvered slots on the front of the...

Страница 13: ...d equipment shutoff valve with 1 8 in NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA design certified equipment shutoff valve from your dealer WARNING Never co...

Страница 14: ...going into pipe Excess sealant in pipe could result in clogged heater valves CAUTION Use pipe joint sealant that is resistant to gas PROPANE or NG We recommend that you install a sediment trap in a s...

Страница 15: ...ction valve must be locked into the NG position Do not operate heater between locked positions 3 Rotate and close cover over gas selection valve and reinstall screw 4 Remove steel or metal hex plug wi...

Страница 16: ...s forming show a leak 5 Correct all leaks immediately 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3...

Страница 17: ...er The remote receiver operates on four 1 5V AA size batteries It is recommended that ALKALINE batteries be used for longer battery life and maximum microprocessor performance IMPORTANT New or fully c...

Страница 18: ...ogs according to the log installation instructions in this manual Flames contacting logs will create soot Figure 22 Installing Log Set IMPORTANT Make sure log does not cover any burner ports see Figur...

Страница 19: ...ection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions...

Страница 20: ...s heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call...

Страница 21: ...ob should be depressed for about thirty 30 seconds This will allow gas to bleed from the gas system 5 With the control knob pressed in push down and released the ignitor button This will light the pil...

Страница 22: ...de SET Sets temperature in thermo mode LCD Liquid Crystal Display 1 DISPLAY Indicates CURRENT room temperature 2 F OR C Indicates degrees Fahrenheit or Ceisius 3 FLAME Indicates bumer valve in operati...

Страница 23: ...SET key The LCD screen will display the set temperature for 3 seconds Then will flash the set temperature for 3 seconds Then the LCD screen will default to display the room temperature Press the MODE...

Страница 24: ...BURNER FLAME PATTERN Figure 36 shows a correct burner flame pattern Figure 37 shows an incorrect burner flame pattern If pilot flame pattern is incorrect then If burner flame is incorrect turn heater...

Страница 25: ...no greater than 30 PSI You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could da...

Страница 26: ...wrong 2 Ignitor electrode is broken 3 Ignitor electrode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad piezo ignitor 7 Low battery 1 Replace electrod...

Страница 27: ...stomer service 3 Contact your gas supplier Delayed ignition of burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner see Care and Maintenance P...

Страница 28: ...urniture 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax and carpet cleaner or similar products...

Страница 29: ...serial number of your heater How heater was malfunctioning Type of gas used Propane LP or Natural gas NG Purchase date Usually we will ask you to return the defective part to the factory PARTS NOT UN...

Страница 30: ...2D201 Hood 1 6 FB32D303 ODS Inlet Tube 1 7 FB32D302 Outlet Tube 1 8 FB32D301 Inlet Tube 1 9 RV83FI 4 9 DF Regulator 1 10 AF 1110 Valve 1 11 FB32D500 Logs Assembly 1 12 FB32D501B Log 1 1 13 FB32D502B L...