kozy heat ROOSEVELT 29 BW Скачать руководство пользователя страница 38

38

  REPLACEMENT PARTS LIST

Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces

#RVT-29-BW R.2 July 2018

15.0  REPLACEMENT PARTS LIST

RVT-29-BW
Hussong Manufacturing Co., Inc.
P.O. Box 577
204 Industrial Park Drive
Lakefield, MN 56150-0577   
USA

GLASS AND GLASS PARTS

Glass with Gasket 26.875” x 17.25”

701-023T

Valance

RT29-005

Glass Gasket

900-006

SAFETY BARRIERS

Arched Mission Screen Front

RT29A-MSF

Arched Full Prairie Door Screen Front

RT29A-FPDSF

Prairie Screen Front

RT29-PSF

Rectangular Screen Front

RT29-RSF

Forged Screen Front

RT29-FSF

LOG SET

Birchwood Log Set

RT29B-501

Ash Panel

RT29-900E-LOG

Log #1

RT29-BW1

Log #2

RT29-BW2

Log #3

RT29-BW3

Log #4

RT29-BW4

Log #5

RT29-BW5

Log #6

RT29-BW6

Log #7

RT29-BW7

Log #8

RT29-BW8

Rock Wool Embers

900-REMB

Replacement parts are available through your local dealer. Contact your local dealer for availability and pricing.

CONTROL BOARD AND PARTS

Control Board - Natural Gas

RT29-160 Pilot Orifice - Natural Gas  #62

700-166

Control Board - Propane

RT29-161 Pilot Orifice - Propane #35

700-168

S.I.T. IPI Gas Valve - Natural Gas

700-567 Valve Step Motor - Natural Gas

700-504

S.I.T. IPI Gas Valve - Propane

700-567-1 Valve Step Motor - Propane

700-504-1

Proflame 2 IFC Board

700-652 15 in. Flexible Gas Line - Black

700-227f

IFC Wire Harness Assembly

700-653 Flexible Gas Line - Valve to Burner Connection

700-226

Proflame 2 IFC External Antenna

700-ANT Natural Gas Burner Orifice #48 FRONT

700-248

Pilot Assembly - Natural Gas

700-551R Natural Gas Burner Orifice #52 BACK

700-252

Pilot Assembly - Propane

700-551R-1 Propane Burner Orifice #56 FRONT

700-256

S.I.T. IPI Pilot Hood

700-098R Propane Burner Orifice #58 BACK

700-258

540 Split Flow

700-595 Conversion Kit - Natural Gas

NCK-RT29-S

Backup Battery Extension

700-424 Conversion Kit - Propane

LCK-RT29-S

9V to Barrel Jack Adapter

700-423 Front Burner 

RT29-350

Program Button Extension

700-422 Back Burner 

RT29-351

Transmitter (Remote Control) with Split flow

700-508 Burner Air Flow Plate

RT29-352

SHROUDS

Blank Shroud (4 pc.) 

RT29-004

4 sided blank shroud (4 pack)

RT29-008

25” x 38” shroud (1 pc.)

RT29-2538

27.5” x 42” shroud (1 pc.)

RT29-27542

30” x 44” shroud (1 pc.)

RT29-3044

Custom shroud

RT29-CUS

Custom arched shroud

RT29-ACUS

LIGHT KIT

Light Kit

RT29-LKT

20W 120V Halogen Bulb

600-676

1.5 lb (0.68kg) Ember Panel Crushed Glass

600-697

FAN KIT

Fan Kit

RT29-028

ADDITIONAL COMPONENTS

Manual Gas Shut-off Valve

700-203

Glass Latch Tool

RT29-GLT

Содержание ROOSEVELT 29 BW

Страница 1: ...manufactured home USA only or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for u...

Страница 2: ......

Страница 3: ...being dedicated not only to functionality and reliability but also customer safety We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your Kozy Heat...

Страница 4: ......

Страница 5: ...ace and Secure Appliance 17 7 0 GAS LINE CONNECTION 18 7 1 Gas Conversion sold separately 18 7 2 Gas Line Installation 18 8 0 FACING AND FINISHING 19 8 1 Clearances to Combustibles 19 8 2 Shroud Insta...

Страница 6: ......

Страница 7: ...y period a battery operated carbon monoxide detector with an alarm shall be installed 1 3 2 Approved Carbon Monoxide Detectors Each carbon monoxide detector as required in accordance with the above pr...

Страница 8: ...e installed at higher altitudes Please refer to National Fuel Gas Code ANSI Z223 1 NFPA 54 CSA B149 1 Natural Gas and Propane Installation Code local authorities or codes having jurisdiction in you ar...

Страница 9: ...TIONS 9 2 2 Appliance Dimensions Figure 2 1 Appliance Dimensions 201 16 510mm 16 406mm 2711 16 703mm 295 8 753mm 197 8 505mm 1715 16 456mm 13 16 31mm 14 356mm 6 172mm 11 8 28mm 129 16 319mm 33 16 81mm...

Страница 10: ...roved parts with this appliance may result in property damage or personal injury Figure 2 2 Proper Positioning of Appliance Table 2 1 Field Assembled Parts A Fireplace insert G Burner air flow plate B...

Страница 11: ...th Hussong Mfg s barriers for this appliance Only doors certified with the appliance shall be used IMPORTANT Consider the height of hearth finish material when building a fireplace platform Proper ins...

Страница 12: ...D label at bottom of existing firebox so it will be visible if this gas fireplace insert is removed 3 2 1 1 Existing Fireplace Opening Minimum Requirements If installing the RT29 FLP add 3 4 19mm tota...

Страница 13: ...1 Vent Termination Clearances WARNING This appliance must not share or be connected to a chimney flue serving any other appliance Approved vent caps require 12 in 305mm clearance to intersecting wall...

Страница 14: ...ce has no gas access hole s provided an access hole of 1 in 37 5 mm or less may be drilled through the lower sides or bottom of the firebox in a proper workmanship like manner The access hole must be...

Страница 15: ...y cause abrasion or damage to the flexible pipes 1 Measure the total chimney length required and cut 816 36 10 97m of 3 flexible pipe to the measured length 2 Carefully extend the exhaust and combusti...

Страница 16: ...through the chimney place unfaced insulation around the first 3 ft 914 mm of vent system below termination cap Secure with wire 2 Install the 3 x 3 flexible pipes down through existing chimney Guide...

Страница 17: ...appliance is properly positioned Figure 6 4 Aligned Insert 6 5 Connect Vent Pipe to Vent Adapter IMPORTANT Proper operation of this insert requires the exhaust pipe and combustion air pipe to be conne...

Страница 18: ...m tee handle manual shut off valve and flexible gas connector are to be connected to the in 13 mm control valve inlet If substituting for these components please consult local codes for compliance If...

Страница 19: ...Clearances to Combustibles IMPORTANT Adequate accessibility clearances for servicing and proper operation must be maintained COMBUSTIBLE MATERIAL 4 102mm 12 305mm 9 229mm 11 286mm 8 210mm 281 8 714mm...

Страница 20: ...Align leg section holes on the shroud to the corresponding mounting nuts in mounting brackets on each side of the insert metal cabinet 3 Secure with 4 phillips truss head screws provided 4 Reinstall...

Страница 21: ...s assembly into position 2 Using the glass latch tool pull latches out and down over latch tabs to secure glass frame assembly bottom 9 2 Light Kit CAUTION Disconnect all electrical power from the fir...

Страница 22: ...along the front of the plate positions at the bottom of the firebox Tilt the bottom of the plate in first The plates will install along the side of the burner and sit on the firebox floor 2 Install t...

Страница 23: ...nversion before installing the log set Follow the conversion instructions included with the kit Log numbers located on the bottom of each log Refer to following instructions and illustrations for prop...

Страница 24: ...ol board on the left side of the firebox 12 Pull out control board out to reveal gas line to disconnect the gas line flex tube from fireplace valve 9 5 2 Control Board Installation 1 Place control boa...

Страница 25: ...ceptacle Do not cut or remove the grounding prong from this plug 10 1 Electrical Specifications This appliance when installed must be electrically grounded in accordance with local codes or in the abs...

Страница 26: ...an ignition device which automatically lights the pilot Do not try to light the pilot by hand 5 Locate the manual valve installed by your qualified service technician 6 Turn the manual valve clockwis...

Страница 27: ...control operation of the main burner and fireplace features 11 3 Reset the System for Manual Operation 1 Set the ON OFF rocker switch to OFF position 2 Press the remote sync button on the IFC module u...

Страница 28: ...h to the OFF position 2 After approximately 2 seconds move the switch to the ON position The ignition sequence will start again 11 6 1 2 Remote Control ON OFF Key 1 Press the remote control ON OFF key...

Страница 29: ...ark to pilot system to the standing pilot option The standing pilot will keep the firebox warm and establish a draft in the vent which allows the main burner to ignite with less air flow disruption Wh...

Страница 30: ...off key and the mode key at the same time 4 Reinsert 1 AAA battery 5 While still holding the on off key let go of ONLY the mode key 6 Index over to the flame graphic on the LCD screen to edit Use the...

Страница 31: ...replace before fan operation The fan will continue to operate for approximately 12 minutes after the fireplace has been turned off Manual mode Fan s will operate at previous setting There is no delay...

Страница 32: ...mum and maximum recommended pressure settings 4 Turn off burner and pilot 5 Disconnect hose and tighten the inlet IN pressure tap by turning screw clockwise Screw should be snug Do not over tighten 6...

Страница 33: ...3 Factory Set Venturi Openings Fuel FRONT BACK Natural Gas 1 16 1 5 mm OPEN 1 16 1 5 mm OPEN Propane 3 8 9 5 mm OPEN 3 8 9 5 mm OPEN 12 2 1 1 Venturi Adjustment NOTE If soot is present on the glass c...

Страница 34: ...Do not over tighten Pilot flame always on or will not extinguish Control system set to CPI mode Set control system to IPI mode Main burner flame will not light ON OFF rocker switch in OFF position Swi...

Страница 35: ...nturi setting Venturi air shutter may need to be opened slightly to allow more air into the gas mix Refer to section 12 2 1 Burner Venturi on page 33 Incorrect vent cap installation Adjust if necessar...

Страница 36: ...uctions provided with installation Refer to Section 6 0 on page 15 Performed by Qualified Service Person Frequency Annually Action Examination of the vent system is required The flow of combustion and...

Страница 37: ...ion device Visually check pilot light when in operation Inspect and ensure the lighting of the main burner occurs within 4 seconds of the main gas valve opening Check for faulty or incorrect wiring an...

Страница 38: ...T IPI Gas Valve Propane 700 567 1 Valve Step Motor Propane 700 504 1 Proflame 2 IFC Board 700 652 15 in Flexible Gas Line Black 700 227f IFC Wire Harness Assembly 700 653 Flexible Gas Line Valve to Bu...

Страница 39: ...f but not limited to improper chimney venting installation will also render this warranty void 7 This warranty does not cover installation and operational related problems such as environmental condit...

Отзывы: