Page 7
START UP PROGRAM SEQUENCE:
Pushing the ‘ON/OFF’ button on the circuit control board activates the start up program for the stove. Operation of
the stove will be in the following sequence:
1. The electronic ignitor probe lights and the combustion fan turns on at high speed. The control board checks
that the Vacuum switch locks in. The convection fan will turn ‘on’ at high speed for 30 seconds.
2. When the board senses the Vacuum switch, the exhaust fan falls to the setting #1 and runs for approximately
5 minutes.
3. After 4 ½" minutes, if the control board senses the ‘Proof of Fire’, it will start feeding the fuel, either corn, wood
pellets, or combination of both on the #1 setting and the convection fan will start. When the control senses
‘Proof of Fire’, the stove has been successfully started.
NOTE: Proof of Fire is established when 110
o
F has been applied to the limit switch located near the
combustion fan.
4. If it does not sense Proof of Fire, the stove will go into ‘Safety shutdown’.
If the control board goes into the ‘Safety Shutdown’, repeat steps 1-4 in the ‘Lighting your Stove’ section.
THERMOSTAT CONTROL
This stove is capable of operating on a thermostat. A feature has been built into the circuit control board which
delays the time between each heat setting to allow for the stove to react at each subsequent level. It will take
the stove approximately 2-5 minutes for the control board to operate at the full capacity for the heat level it has
been set to.
As the room temperature falls below the thermostat temperature setting, the stove will operate at one of the (5)
settings previously chosen. When the room temperature reaches the thermostat set temperature, the stove will
automatically operate at the lowest setting (#1). NOTE: The LED will remain lit at the thermostat setting.
DIAGNOSTIC FEATURES
The following diagnostic information is being provided in the event that the stove is not functioning properly. It will
guide you through the possible problem and solution.
Note the 5 LED lights on the control board. (These are used to determine the heat level settings.)
POWER RESET:
When all the lights on the control board are simultaneously lit and the circuit control board
is not responding:
1. Unplug the stove.
2. Wait 10 seconds.
3. Plug the stove back in and resume as normal.