  OPERATING INSTRUCTIONS

11.1  Setup Proflame 2 IFC Module

1.  Set the main ON/OFF rocker switch in the OFF position.
2.  Install (4) AA batteries (included in the components packet) 

into backup battery holder on the control module. 

3.  Install (3) AAA batteries (included in the components packet) 

in the remote control battery bay, located at the base of the 
remote.

4.  Connect the IFC Module to an AC power supply.

11.2  Initialize the Control System

IMPORTANT: Remove all packaging and combustible material 
from the firebox before initializing the control system.
NOTE: Performing the next steps will initiate pilot start-up in 
manual mode, where the pilot igniter will spark repeatedly. The 
pilot will ignite if gas is supplied to the fireplace. 

1.  Locate the red SW1 button the IFC module.
2.  Press the button. The IFC module will BEEP (3) times and 

illuminate an amber LED. This indicates the receiver is ready 
to synchronize with the transmitter.

3.  Within (5) seconds, push the ON/OFF button on the 

remote control. The receiver will BEEP (4) times to indicate 
the transmitter’s command is accepted, and is set to the 
transmitter’s particular code. The pilot will automatically ignite. 

4.  Press the remote control ON/OFF button again. The pilot 

will extinguish, confirming the remote control command. The 
control system is now initialized. 

5.  Set the main ON/OFF rocker switch to ON position for remote 

control operation of the main burner and fireplace features.

11.3  Reset the System for 

Manual Operation

1.  Set the ON/OFF rocker switch to OFF position. 
2.  Press the red SWI button on the IFC module until it emits (3) 

beeps and an amber LED is illuminated. 

3.  Within (5) seconds, press the red SWI button again. This will 

close synchronization with the remote control. The pilot will 
automatically light. 

•  Turn the main burner ON by setting the ON/OFF switch in ON 

position. The main burner will only operate on HI. 

Figure 11.1, IFC Module

•  Turn the main burner OFF by setting the ON/OFF switch in the 

OFF position. The pilot will remain lit even if burner is turned 
off, provided CPI mode is turned on. 

11.4  Automatic Safety Restart

•  This system will execute an automatic turn OFF command 

within (24) hours of a continued pilot flame ignition. This allows 
the system to verify correct safety functions. 

•  After the turn OFF sequence is completed, the IFC module will 

re-execute the latest command. 

11.5  Backup Battery Operation 

This appliance will operate on the backup battery pack when 
electric power is interrupted, or in a power outage. The lifespan of 
the backup batteries depend on various factors, such as the quality 
of the batteries, number of ignitions, et cetera. 
•  When the backup battery pack is low, the IFC module will emit 

a double-beep while receiving an ON/OFF command. 

•  No commands will be accepted after this alert until the back 

up batteries are replaced. 

•  Once replaced, the IFC module will emit a ‘beep’ as soon as 

it is powered. 

SW1 

BUTTON

LEDs

Содержание JORDAN-34S

Страница 1: ...RE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage This appliance may be installed in an aftermarket permanently located manufactu...

Страница 2: ......

Страница 3: ...r safety We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your Kozy Heat gas fireplace Jim Hussong President Dudley Hussong Board Chairman Homeown...

Страница 4: ......

Страница 5: ...CONNECTION 18 7 1 Gas Conversion sold separately 18 7 2 Gas Line Installation 18 8 0 FACING AND FINISHING 19 8 1 Clearances to Combustibles 19 8 2 Shroud Installation 20 8 3 Safety Barrier Installatio...

Страница 6: ......

Страница 7: ...accordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 1 2 3 Signage A metal or plastic identification plate shall be permanently mounted to the...

Страница 8: ...ns Natural Gas LP Gas Maximum Input Rating 39 000 Btu h 11 43 kW 39 000 Btu h 11 43 kW Minimum Input Rating 17 000 Btu h 4 98 kW 17 000 Btu h 4 98 kW Manifold Pressure High 3 8 WC 95 kPa 11 WC 2 74 kP...

Страница 9: ...Opening Width D 30 1 4 768 Back Width E 28 3 16 716 Depth F 16 3 8 416 Height to Air Duct Top G 25 1 8 638 Unit Bottom to Gas Line Access H 14 1 8 360 Back to Gas Line Access I 1 1 4 32 Unit Bottom t...

Страница 10: ...e to use only specified approved parts with this appliance may result in property damage or personal injury Table 2 2 Field Assembled Parts A Fireplace insert F Back burner assembly B Module panel ass...

Страница 11: ...shall be replaced with Hussong Mfg s barriers for this appliance Only doors certified with the appliance shall be used Please refer to Section 8 3 Safety Barrier Installation on page 20 for installati...

Страница 12: ...8 in 416 mm D Back Width 283 16 in 716 mm If installing the JXL FLP add in 19 mm total dimension of floor protector and airspace to height to maintain minimum existing fireplace height opening requir...

Страница 13: ...appliance must not share or be connected to a chimney flue serving a separate solid fuel burning appliance Approved vent caps require 12 in 305mm clearance to intersecting walls overhangs or eaves as...

Страница 14: ...to Section 7 0 Gas Line Connection on page 18 If the factory built fireplace has no gas access hole s provided an access hole of 1 in 37 5 mm or less may be drilled through the lower sides or bottom...

Страница 15: ...ination cap with the exhaust collar on the right side NOTE The exhaust pipe will have a red marking IMPORTANT Maximum horizontal vent runs of 24 in 609 mm require a 1 in 25mm rise per 12 in 305 mm run...

Страница 16: ...mination cap into position as instructed by vent system manufacturer s installation manual OPTIONAL Kozy Heat 816 CL Secure termination cap to existing chimney with 2 in 50 mm self tapping screws and...

Страница 17: ...joint to ensure an air tight seal Figure 6 4 Vent Pipes Connected to Air Duct FLEXIBLE PIPES SHEET METAL SCREWS 3 TOTAL SEALANT SEALANT 6 5 Place and Secure Appliance 1 Slide the gas fireplace insert...

Страница 18: ...t be isolated from the gas supply piping system by closing its individual manual shut off valve A listed and Commonwealth of Massachusetts approved in 13 mm tee handle manual shut off valve and flexib...

Страница 19: ...for servicing and proper operation must be maintained COMBUSTIBLE MATERIAL 3 76mm CLEARANCE TO ADJACENT SIDEWALL Hearth Protection X Combustible Floor Y 0 in 0 mm 6 1 4 in 159 mm 6 in 203 mm 3 1 8 in...

Страница 20: ...orresponding mounting nuts in mounting brackets on each side of the insert metal cabinet 3 Secure with 4 phillips truss head screws provided 4 Reinstall glass frame assembly 8 3 Safety Barrier Install...

Страница 21: ...ng the bottom of the glass assembly into position 2 Using the glass latch tool pull latches out and down over latch tabs to secure glass frame assembly bottom Figure 9 1 Lower Latch 1 each side Figure...

Страница 22: ...nstructions and illustrations for proper log placement 1 Place the ember panels behind the front burner ports as shown below 2 Align the holes in the bottom of logs J34 1 J34 2 and J34 3 with the moun...

Страница 23: ...rews at the back of the firebox and 2 screws on each front corner 8 Remove 10 screws securing the control board on the left side of the firebox 9 Pull out control board out to reveal gas line to disco...

Страница 24: ...remove the grounding prong from this plug 10 1 Electrical Specifications This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes wi...

Страница 25: ...appliance will not operate follow the instructions To Turn Off Gas To Appliance and call your service technician or gas supplier OPERATING INSTRUCTIONS NOTE When this fireplace is initially lit conde...

Страница 26: ...osition for remote control operation of the main burner and fireplace features 11 3 Reset the System for Manual Operation 1 Set the ON OFF rocker switch to OFF position 2 Press the red SWI button on t...

Страница 27: ...y 2 seconds move the switch to the ON position The ignition sequence will start again 11 6 1 2 Remote Control ON OFF Key 1 Press the remote control ON OFF key to turn the system OFF 2 After approximat...

Страница 28: ...tion The standing pilot will keep the firebox warm and establish a draft in the vent which allows the main burner to ignite with less air flow disruption When the system is OFF the LCD screen will dis...

Страница 29: ...be set to a desired temperature to control a room s comfort level To activate this function 1 Press the thermostat key The LCD screen will display a temperature bulb graphic the room temperature and s...

Страница 30: ...time for heat to build in fireplace before fan operation The fan will continue to operate for approximately 12 minutes after the fireplace has been turned off Manual mode Fan s will operate at previo...

Страница 31: ...ximum recommended pressure settings 4 Turn off burner and pilot 5 Disconnect hose and tighten the inlet IN pressure tap by turning screw clockwise Screw should be snug Do not over tighten 6 Relight pi...

Страница 32: ...1 Venturi Opening Adjustment NOTE If soot is present on the glass check log positioning before adjusting the venturi Logs must not block burner ports IMPORTANT Slight adjustments to the venturi openin...

Страница 33: ...it No LP propane gas in tank Check LP propane tank Refill if necessary Low gas pressure Consult a plumber or a gas supplier Can be caused by situations such as a bent line too narrow diameter or pipe...

Страница 34: ...mix Refer to Section 12 2 1 Burner Venturi on page 32 Incorrect vent cap installation Adjust if necessary Vent cap blockage Remove debris if necessary Flame burns blue and lifts off burner Improper ve...

Страница 35: ...Vent System NOTE If the vent air intake system is disassembled for any reason reinstall per instructions provided with installation Refer to Section 6 0 Installation on page 15 Performed by Qualified...

Страница 36: ...BACK 700 251 540 Split Flow 700 595 Conversion Kit NG NCK J34 S Transmitter Remote Control with Split flow 700 508 Conversion Kit LPG LCK J34 S Pilot Orifice NG 62 700 166 Front Burner J34 350 Pilot...

Страница 37: ...ng Manufacturing Co Inc s behalf any additional obligation of liability connected with the unit It is expressly agreed and understood that this warranty is Hussong Manufacturing Co Inc s sole obligati...

Страница 38: ......

Страница 39: ...efective component s It is expressly agreed and understood that this Lifetime Warranty is Hussong Manufacturing Co Inc s sole obligation and original purchaser s exclusive remedy for defective firepla...

Отзывы: