PLACEMENT CLEARANCE REQUIREMENTS
This fireplace must be installed on a level surface capable of supporting the fireplace and venting.
This fireplace insert is to be installed into a solid fuel masonry or factory built non-combustible fireplace that has been installed in
accordance with the National, Provincial, State and local building codes.
Due to high surface temperatures, fireplace should be located out of traffic and away from furniture and draperies.
This fireplace may be installed in a bedroom.
Please be aware of the large amount of heat this fireplace will produce when determining a location.
SPECIFICATIONS
ADDITIONAL COMPONENTS REQUIRED
Vent System:
Part #816-
CL: For use with minimum 6” x 8” I.D. masonry or 7” I.D. Class A metal chimneys
- Includes 12ft. (3.66m)
compressed, expandable to 35ft. (10.67m) co-
linear 3” x 3” flexible chimney, and termination cap.
Other approved venting
: ICC, Selkirk, American Metals, Simpson Dura-Vent, RLH, Security, Metal Fab
Approved caps listed on page 10.
Shrouds:
Standard shrouds are available for this insert and will fit most applications. Custom shrouds may be ordered on a non-returnable
basis. When ordering a custom shroud, please specify the existing fireplace front opening height and width.
or
Blank Shrouds:
Blank shrouds are available for on-site custom fit applications and are sized to the opening after the insert has been
installed. The interior perimeter is properly sized to fit onto the insert. The outer perimeter must be cut, formed and
finished (painted).
To be used with;
Screen Front:
Screen Fronts in various finishes.
EXISTING FIREPLACE SPECIFICATIONS
THIS INSERT IS APPROVED FOR INSTALLATION IN MASONRY AND FACTORY-BUILT SOLID FUEL BURNING FIREPLACES.
EXISTING FIREPLACE REQUIREMENTS
2. Position one person at fireplace and another person at top of chimney.
Measure from fireplace base to top of chimney.
Subtract 19-
3/4” (501mm) (height of insert).
This is the total length of co-linear flexible aluminum you will require.
MEASUREMENT FROM FIREPLACE BASE TO TOP OF CHIMNEY:_________________
LESS 19-3/4" (501mm) (HEIGHT OF INSERT): -19-3/4" (501mm)_
TOTAL CHIMNEY LENGTH REQUIRED:
_________________
DETERMINE LENGTH OF EXISTING CHIMNEY
MIN. 10ft. (3.05m)
MAX. 35ft. (10.67m)
Figure 7a
CAUTION
This appliance must not be connected to or joined with any other
chimney flue serving another appliance.
NOTE
It is helpful to have two people complete next step to determine
chimney height.
The existing fireplace & chimney must be clean and in good working order and constructed of non-combustible materials.
A gas line must be able to be installed to the insert.
Provisions made to provide electrical power for operation.
Any chimney clean-outs must fit properly.
Existing Chimney must be comprised of one of the following: Factory built solid fuel chimney: 7” minimum inside diameter.
Masonry chimney: 6" x 8" minimum inside diameter.
Existing Chimney Height: Minimum: 10ft. (3.05m)
Maximum: 35ft. (10.67m)
1.