15
speCiFiCations
model
Chaska 34 ipi
Chaska 335s
Chaska 29 ipi
Chaska 29 mV
Chaska 25
height
23”
23”
19-1/4”
19-1/4”
17-1/2”
Width
33-3/8”
33-3/8”
29”
29”
25-3/8”
Back Width
24-3/8”
24-3/8”
18-7/8”
18-7/8”
20-3/8”
Depth
16”
16”
14-1/2”
14-1/2”
15”
Weight
150 lbs.
150 lbs.
140 lbs
140 lbs
140 lbs
viewing area
30-1/8” X 17-13/16”
29-5/8” X 15-13/16”
26-1/8” X 12-7/8”
26-1/8” X 12-7/8”
22-1/8” X 12-5/16”
NG high / low
34,000 / 18,500
36,000 / 22,000
30,500 / 16,000
28,500 / 18,500
26,000 / 13,500
lP high / low
34,000 / 18,500
36,500 / 22,000
30,000 / 16,000
29,000 / 22,000
25,500 / 13,000
efficiencies NG / lP
77% / 77%
80% / 75%
74% / 74%
74% / 74%
78% / 78%
eNeRGUiDe P.4
NG 74.8% / LP 75.4%
NG 65.3% / LP 66.15%
73%
73%
NG 77.58% / LP 78.17%
valve system
IPI - Standard on all Verisons
Millivolt
IPI - Standard on all Verisons
Millivolt
IPI
standard Refractory
Brick
(Csk 34-l)
Brick
Brick
(Csk 29-l)
Brick
Brick
standard Black enamel
Refractory
(Csk 34-R)
Back curved black panel
(Csk 34-G)
Optional
(Csk 34-l)
N/A
(Csk 29-R)
Back curved black panel
(Csk 29-G)
Optional
(Csk 29-l)
N/A
N/A
ember light kit
Standard
(Csk 34-l, Csk 34-R)
N/A
Standard
(Csk 29-l, Csk 29-R)
N/A
N/A
accent light kit
Standard
(Csk 34-G)
N/A
Standard
(Csk 29-G)
N/A
N/A
Glass Media
Required
(Csk 34-G)
N/A
Required
(Csk 29-G)
N/A
N/A
Fan kit availability
Standard for All Versions
Standard
Standard for All Versions
Standard
Standard
screen Front
Required
Required
Required
Required
Required
model
Chaska 34
Chaska 335s
Chaska 29 ipi
Chaska 29 mV
Chaska 25
From insert to combustible floor
in front
Refer to chart in manual
Refer to chart in manual
Refer to chart in manual
Refer to chart in manual
Refer to chart in manual
From insert to side wall
6”
12”
6”
6”
3”
Mantel 9” deep from top of insert*
16”
16”
16”
16”
9”
Clearances
Features, Options & Specifications are subject to change.
The Chaska 34 (CSK 34-L, CSK 34-G & CSK 34-R), Chaska 29 (CSK 29-L, CSK 29-G & CSK 29-R) and Chaska 25 come standard with an Electronic Ignition Pilot System. The included Komfort Kontrol remote will adjust the flame
and fan spead. The Chaska 335S model comes standard with a millivolt operating system, refractory brick lining & fan kit. The Chaska 29 model offers an optional millivolt operating system, refractory brick lining & fan kit.
Refer to the installation manuals for complete installation & venting requirements. See additional mantel clearance configurations in the installation manual.
Note: Over time, antique copper will react with oxygen, heat, and other aspects of the environment and naturally change color, or patina.
each unit factory tested
vertical Termination oNlY (Chaska 34 & Chaska 335s)
Minimum vent run:
12’
Maximum vent run:
50’
vertical Termination oNlY (Chaska 25)
Minimum vent run:
10’
Maximum vent run
35’
vent system approval & Requirements
These models are approved for use with the
following Vent Systems only:
• Kozy Heat™ - #816 venting
• Simpson Dura-Vent™
• Selkirk Metalbestos™
• Ameri-Vent™
• ICC™