FRAMING
13
3.0 FRAMING
3.1 Appliance Placement
Considerations
WARNING: Due to high temperatures, the appliance should be
located out of traffic and away from furniture and draperies.
FIRE HAZARD: Do NOT install this appliance directly on
carpeting, vinyl, or any other combustible material other than
wood.
• This appliance must be installed on a level surface capable
of supporting the fireplace and venting. If possible, place the
fireplace in a position where the vent terminates between two
studs, eliminating the need for any additional framing.
• This fireplace may be installed in a bedroom.
• Please be aware of the large amount of heat this fireplace will
produce when determining a location.
1”
(25mm)
1”
(25mm)
15
7⁄8
”
(404mm)
14
7⁄8
”
(378mm)
1”
(25mm)
5”
(127mm)
Table 3.1, Minimum Clearances to Combustible Material
From appliance top corner to side wall
1 in
25 mm
From appliance top corner to back wall
5 in
127 mm
From appliance top to ceiling
35-3/4 in
908 mm
From top of horizontal pipe surface to ceiling
3-1/8 in
80 mm
Figure 3.1, Typical Install Options
35
¾
”
(908mm)
3
1⁄8
”
(80mm)
65
1⁄8
”
(1654mm)
PEDESTAL BASE
35
¾
”
(908mm)
3
1⁄8
”
(80mm)
65
1⁄8
”
(1654mm)
CONTEMPORARY BASE
35
¾
”
(908mm)
3
1⁄8
”
(80mm)
60”
(1524mm)
TRADITIONAL LEGS