13
FACING AND FINISHING
This fireplace was designed to accommodate non-
combustible facing material up to 1/2” (13mm) thick. Install non
-combustible facing
material up to facing flange surrounding the glass frame assembly. Do not apply any material beyond this point. The glass frame assembly
must be removable.
Non-combustible material surrounding fireplace face is required. Illustrations below reflect minimum non-combustible material dimensions.
It is acceptable to pre-drill holes and use self-tapping screws to attach non-combustible material to fireplace face with the exception of the
lower left corner. See Figure 13c. Do not use excessively long screws.
WARNING
Maintain minimum clearances to combustibles from fireplace and vent system.
COMBUSTIBLE MATERIAL
ALLOWED
NON-COMBUSTIBLE MATERIAL
ONLY
NON-COMBUSTIBLE MATERIAL
ONLY
NO SCREWS ALLOWED
Facing flange
Figure 13a
Figure 13c
Figure 13b
72”
(1829mm)
9-
7/16”
(240mm)
37-
15/16”
(964mm)
32”
(813mm)
5-
3/8”
(137mm)
14-
1/2”
(362mm)
1-
9/16”
(40mm)
72”
(1829mm)
13-
3/8”
(339mm)
5-
3/8”
(137mm)
32”
(813mm)
38”
(965mm)
5-
3/8”
(137mm)
1-
9/16”
(40mm)