(3) HYP-AGC
This option provides a higher level of automatic sensitivity adjustment mode than the AGC
mode. Compared with the AGC mode, it pr 6 dB for S/N, + 6 dB for STD, and + 18 dB
for MOVE.
* When the SENSEUP setting is configured to any of S/N, STD, or MOVE or the DAY/NIGHT
setting is configured to AUTO, you can select only AGC or HYP-AGC for the GAIN setting.
2-1-6. WHITE BAL
You can use the L and R buttons to switch the white balance mode.
(1) ATW1
This mode automatically tracks and adjusts the white balance.
(2) ATW2
This mode automatically tracks and adjusts the white balance. It provides a wider
color-temperature range than the ATW1 mode and supports sodium-vapor lamps. Note that this
mode may produce color deviations unlike ATW1, however.
(3) AWC
This option provides one-touch automatic white balance control. With the target achromatic color
(white or gray) shown on the screen, press the E button to let the camera automatically adjust the
white balance.
(4) MANUAL
This mode allows you to adjust R GAIN and BGAIN to obtain the desired white balance.
2-1-7. DNR
You can use the L and R buttons to select the desired option for the noise reduction effect.
(1) OFF
The noise reduction feature does not function.
(2) LOW
The option provides low-level noise reduction.
(3) HIGH
The option provides high-level noise reduction.
* The level of the noise reduction is proportional to the AGC GAIN level. When the GAIN level is low,
the noise reduction level is low. When the GAIN level is high, the noise reduction level is high.
* When the HIGH option is selected and the GAIN level becomes high, the 3-D noise reduction effect
may produce residual images.
2-1-8. MENU LOCK
The camera provides a menu locking feature that prevents the settings configured through MENU from
being reset accidentally.
(1) To lock the settings:
Use the E button to set the locking feature to ON.
(2) Behavior
Содержание SC200PK1C