You can use the L and R buttons to select a high shutter speed of:
OFF (1/30 or 1/25), 1/50, 1/60, 1/100, 1/125, 1/250, 1/500, 1/1,000, 1/2,000, 1/4,000, or 1/10,000
(2) When the SENSEUP setting is configured to S/N, STD, MOVE, or MANUAL:
You can use the L and R buttons to set the magnification of the electronic sensitivity enhancement to
the following:
1x, 2x, 4x, 8x, or 16x
* Tip about the menu indication
Next to SHUTTER, two different magnifications are indicated: the set maximum magnification and
actual enhanced sensitivity.
SHUTTER x16
x1
Magnification set in the above step. Actual enhanced magnification
When the actual magnification is greater than the set magnification as shown above, it is
considered that the light is sufficient in amount. Note that when the SENSEUP setting is configured
to MANUAL, the same figures are shown.
2-1-3. BLC MODE (Backlight Correction)
You can use the L and R buttons to select the desired option for the backlight correction setting.
(1) OFF
This option should be selected in normal cases.
(2) ON
The backlight correction feature is enabled.
(3) SPOT
This option allows you to specify the area to be metered. The SPOT SET setting screen provides
a matrix of 9 x 5. You can use the U, D, L, and R buttons to move the cursor and press the E button
to fill the selected cell. The areas filled will not be metered.
2-1-4. ALC LEVEL
You can use the L and R buttons to adjust the convergence value for automatic exposure control.
Moving the marker rightward brightens the image. Move the marker to an appropriate position while
seeing the actual image.
2-1-5. GAIN
You can use the L and R buttons to select the desired option for the GAIN setting.
(1) MANUAL
This option allows you to manually adjust the GAIN. Press the E button to display an adjustment
screen.
(2) AGC
This option automatically adjusts the sensitivity according to the brightness of each scene.
Содержание SC200PK1C
Страница 2: ...1 Names and Functions of Parts...