Redundant Network Connection

IPCorder  KNR-5016/5024/5032/5040  supports  the  Backup  Network  Interface  function.  This  service  prevents
disconnection from the network in case of failure of one of network routes (both network adapters of the IPCorder must
be connected). This can prevent unavailability of the IPCorder in case of unwanted removal of a network cable or switch
failure. To set up this service:

1) Connect the second network cable to your IPCorder (use network adapter number 2) and to the switch.

2) Go to the Nework tab in the web interface of the IPCorder:

• If Service mode is active – continue to the 

Network

page and if needed set up the basic network settings.

• If Normal mode is active - go to the 

Settings

menu in the upper part of screen, then select 

Configuration – Network

and if needed set up the basic network settings.

3) Check the 

Enable second network interface as backup

option in the 

Backup Network Interface

section.

4) Choose method of the 

Failure detection

:

Link (cable connected)

– this option detects disconnection of the network cable. If the cable from network adapter

no. 1 is removed, the connection through the network adapter no. 2 will be automatically activated and vice versa.

Network (ping address from the list)

– this option checks if there is any traffic running through the active

network adapter of the IPCorder. If no network traffic is detected, the connection through the backup network
adapter will be automatically activated. Type at least one IP address of the independent server to the 

IP address

list

text field.

5) In the 

Check Interval

text field, set the interval for checking availability of the connection, the default value is set

to 100 ms, the typed value is used for both types of failure detection.

6) Click the 

Apply

button to confirm the settings (use buttons 

Apply Changes

and 

Restart

if Service mode is active).

Note: The Backup Network Interface function is active only in Normal mode. If you are using DHCP server to obtain an
IP address, it is possible that after the settings are confirmed, your IPCorder will temporarily obtain another IP address.

Содержание KNR-5016

Страница 1: ...nsuitable environment The device is not designed for outdoor use Do not use the device in an environment with strong vibrations Unauthorized modification of this device can damage it or cause a fire Prevent from contact with fluids do not expose the device to high temperatures Protect the device from falling It is permitted to use accessories only intended for the device hard disks cables etc In c...

Страница 2: ...val of the disk an installation CD two screws for securing the back panel the installation guide and licence agreement 2 How to install IPCorder in several minutes Up to five 3 5 inch SATA I SATA II or SATA III disks in various combination can be inserted in the IPCorder KNR 5016 5020 5032 5040 the individual positions are numbered as follows ...

Страница 3: ...ter network see Redundant Network Connection Firstly connect the original power adapter to IPCorder and then plug it into an electric outlet On start up IPCorder will attempt to obtain the IP address automatically via DHCP If unsuccessful it is set up to the default value of 192 168 1 78 If the IPCorder is in the same subnet as the PC used to access it it should appear in the Network Places folder...

Страница 4: ... will be indicated by a lit red diode with an exclamation mark symbol You will be asked to configure the RAID array on the Storage Configuration screen After its successful creation restart to the Normal mode The Normal mode is indicated when the blue diodes light up You will find more information about the configuration in the relevant user manual on the enclosed CD The login window will shortly ...

Страница 5: ...ethod of the Failure detection Link cable connected this option detects disconnection of the network cable If the cable from network adapter no 1 is removed the connection through the network adapter no 2 will be automatically activated and vice versa Network ping address from the list this option checks if there is any traffic running through the active network adapter of the IPCorder If no netwo...

Страница 6: ... signals the length of the pressed Reset button If pressed for less than 5 seconds the diode is on if pressed for more than 5 seconds it blinks slowly and if pressed for more than 15 seconds it blinks quickly Button function description Button ON OFF If pressed for less than 3 seconds it will switch off the acoustic signal in defined cases see below If pressed for more than 5 seconds accompanied b...

Страница 7: ...entry in the log By a continuous sound if the temperature of the device exceeds 70 C The device in this case will make an entry in the log send an information e mail if the SMTP is set up and will be automatically switched off If the temperature limits are exceeded the acoustic signal is accompanied by the blinking of a red light on the lightstrip 4 System Requirements The system requirements are ...

Страница 8: ...AAM Team The manufacturer bears no responsibility for any technical or printing errors and reserves the right to make any changes in the product and in this User Manual without prior notice Any such changes shall be announced via the product s website The manufacturer does not provide warranties of any kind whatsoever with regard to any information given in this user manual or any derived warranti...

Отзывы: