kosmek WPT Series Скачать руководство пользователя страница 3

Sensor for Air Cylinder

JES

High-Power 

Pull Stud Clamp

WPT

Performance

Curve

External

Dimensions

Installation

Method

Accessory

Sensor for Air Cylinder

Cautions

Model No.

Indication

Specifications

Features

Features

Model

  

WPT

For Various Applications: Pallet Transfer, Robotic Hand Gripper Change, etc.

Clamps with the Pull Bolt. Compact Body with Powerful Holding Force

High-Power Pull Stud Clamp

Connect the Pull Bolt with the Pull Stud Clamp

Compact, Light, yet Powerful

Powerful

Action Detection with Sensor

Fall Prevention with Self-Locking Spring

Application Examples

2

1

Exerts Powerful Clamping Force and 
Holding Force with Mechanical Lock

Actions of the Pull Stud Clamp can be detected 
by using with the Sensor for Air Cylinder.

Refer to P.12 for further information.

Self-locking spring enables to hold a workpiece
even when air is accidentally cut off.

※ Make sure to supply lock air for normal use.

Detached (Released) State

Connected (Locked) State

Release Air Pressure:ON

Lock Air Pressure:OFF

Release Air Pressure:ON

Lock Air Pressure:OFF

Release Air Pressure:OFF

Lock Air Pressure:ON

The pull bolt is pulled in by the piston and steel balls with

lock air + spring force to complete the locking operation.

Insert the pull bolt.

Provide release air pressure, 

allowing for pulling in and out the pull bolt.

※ Simplified internal structure. Actual components are different.

Workpiece Setting (Before Connected)

Pallet, Workpiece, etc.

Pull Bolt

Self-Locking Spring

Accidental air cut off !

Air drops to 0MPa.

Safe

Pallet/Workpiece/Application Transfer. Allows for more compact hand.

Pallet Setup by Using with Locating Pin

Stocker for Robotic Hands

Gripper Change for Robotic Hands

Pull Bolt

Pull Stud Clamp

Pull Stud

Clamp

Seating

Surface

2 larger sizes added to the lineup!

(August, 2019)

Light

Max. Holding Force

Weight

 WPT0500: 55g
 WPT0600:95g
 WPT0800:155g
 WPT1000:215g

 WPT0500: 768N
 WPT0600:1234N
 WPT0800:1918N
 WPT1000:2436N

Содержание WPT Series

Страница 1: ...Model WPT Compact and Versatile Use For Transfer Robotic Hand Gripper Change Tool Holding etc High Power Pull Stud Clamp New 2 Larger Sizes Added to the Lineup...

Страница 2: ...r Pressure ON Lock Air Pressure OFF Release Air Pressure OFF Lock Air Pressure ON The pull bolt is pulled in by the piston and steel balls with lock air spring force to complete the locking operation...

Страница 3: ...s of the Pull Stud Clamp can be detected by using with the Sensor for Air Cylinder Refer to P 12 for further information Self locking spring enables to hold a workpiece even when air is accidentally c...

Страница 4: ...Force at 0MPa 1 Cylinder Capacity Lock Side cm3 Release Side Maximum Operating Pressure Minimum Operating Pressure Withstanding Pressure Operating Temperature Range Usable Fluid Weight N N N MPa MPa...

Страница 5: ...Clamping Force Holding Force Air Pressure at 0 5MPa at 0 4MPa at 0 3MPa at 0MPa WPT0600 Clamping Force N 602 497 393 Holding Force N 1234 1019 806 170 3 Clamping Force Holding Force Force that withst...

Страница 6: ...minal Pitch M3 0 5 M4 0 7 M3 0 5 Number of Bolts 4 4 4 1 2 3 1 DWG 1 Bolt Down Mounting DWG 2 Bolt Up Mounting DWG 3 Bolt Up Mounting Note 1 WPT does not include Pull Bolt WPWZ Please order separately...

Страница 7: ...tion DWG 1 Bolt Down Mounting DWG 2 Bolt Up Mounting DWG 3 Bolt Up Mounting M3 0 5 M4 0 7 M3 0 5 Number of Bolts 4 4 4 1 2 3 1 DWG 1 Bolt Down Mounting DWG 2 Bolt Up Mounting DWG 3 Bolt Up Mounting No...

Страница 8: ...P1 9 0 N m High Power Pull Stud Clamp WPT0800 Pull Bolt WPWZ800 P1 Model No WPT0800 Mounting Direction DWG 1 Bolt Down Mounting DWG 2 Bolt Up Mounting DWG 3 Bolt Up Mounting Mounting Bolt Nominal Pit...

Страница 9: ...WPWZ Please order separately DWG 1 Bolt Down Mounting DWG 2 Bolt Up Mounting DWG 3 Bolt Up Mounting High Power Pull Stud Clamp WPT1000 Pull Bolt WPWZ1000 P1 Model No WPT1000 Mounting Direction DWG 1 B...

Страница 10: ...der to avoid malfunction or breakage of the device 4 Please supply ltered clean dry air Oil supply with a lubricator etc is unnecessary 5 Operating Environment WPT has no function that prevents contam...

Страница 11: ...th tensile strength of A2 70 or greater and tighten the product with the tightening torque listed on P 5 P 8 The tightening torque for pull bolt is shown below Installation failure causes air leakage...

Страница 12: ...intenance and inspection are not carried out If the product is used while it is not suitable for use based on the operator s judgment resulting in defect If it is used or handled in inappropriate way...

Страница 13: ...is small we recommend the 3 wire sensor of the high accuracy sensor for air cylinder model JES0000 02 in order to ensure stable detections Sensor for Air Cylinder model JES The Usage Example of Sensor...

Страница 14: ...n Output Current Current Consumption Response Speed Case Material Indicator Light Withstand Voltage Insulation Resistance Operating Temperature Range Operating Humidity Range Protection Grade Cable Le...

Страница 15: ...d JES0000 02LG JES0000 02LGP 16 8 2 2 8 3 8 4 6 10 4 5 Cylinder Sensor Circuit Max 15mA Blue Cable Black Cable Output Red Brown Cable DC 5 24V Max 80mA Blue Cable Black Cable Output Brown Cable DC 5 2...

Страница 16: ...tters 4 Do not use the product in an environment where it is continuously exposed to coolant or chemical liquid Although IEC standard IP67 structure is satis ed please avoid using sensors in an enviro...

Страница 17: ...efects or failures caused by the following are not covered If the stipulated maintenance and inspection are not carried out If the product is used while it is not suitable for use based on the operato...

Страница 18: ...l 2 First Floor Prestige Center Point Cunningham Road Bangalore 560052 India INDIA BRANCH OFFICE FAX 66 2 300 5133 TEL 66 2 300 5132 Av Santa Fe 103 int 59 Col Santa Fe Juriquilla C P 76230 Queretaro...

Отзывы: