High-Power

Pull Stud Clamp

Sensor for Air Cylinder

model 

JES

16

15

Application Table

Specifications

Model No. Indication

Electric Circuit

Diagram

External Dimensions

Cautions

High Accuracy Sensor for Air Cylinder (Oil Resistant)

 Cautions

Cautions

●  

Notes for Design

1)  Check the Specifications
 

  Please use each product according to the specifications. 

 

The product may be damaged or malfunction if used 

 

outside the range of load or specifications.

2)  Notes on Use in the Interlock Circuit
 

  When the sensor is used for an interlock signal that requires 

 

high reliability, please use a double interlock system by providing 

 

a mechanical protection function. Or by using another sensor 

 

together with the product. Also, please perform periodic 

 

maintenance and confirm proper operation.

3)  Please avoid using loads that generate surge voltage.
 

 If driving a relay, put a Zener diode in parallel for surge protection.

●  

Notes on Operating Environment

1)  Never use the product in an atmosphere with explosive gases.
 

 Sensor for Air Cylinder is not designed to prevent explosion. 

 

Do not use the product in an atmosphere with explosive gases 

 

since it may cause serious explosions.

2)  The product may malfunction if an intense magnetic field is 
 

applied to a pole body.

3)  Make sure to prepare shield measures when using in the following 
 

environments.

 

  Where large current and/or strong magnetic field are generated.

 

  Where noise occurs due to static electricity, etc.

 

  Where magnetic powder or dust such as iron powder occurs or scatters.

4)  Do not use the product in an environment where it is continuously 
 

exposed to coolant or chemical liquid.

 

 Although IEC standard IP67 structure is satisfied, please avoid  using 

 

sensors in an environment where continuously exposed to coolant 

 

or chemical liquid. This may cause insulation failure or malfunction.

5)  Do not use the product in an environment with oil or chemicals.
 

  If sensors are used in an environment with coolant or 

 

cleaning solvent, even in a short time, they may be adversely 

 

affected by improper insulation, malfunction due to swelling 

 

of potting resin and or hardening of electric cable.

6)  Do not use the product in an environment with excessive 
 

vibrations or impacts.

●  

Installation Notes

1)  Electric Wiring Reverse Connection Protection
 

 Follow the electric circuit diagram on P.14 and make sure to

 

connect properly. Never connect the power reversely.

2)  Tighten sensors with appropriate tightening torque.
 

 Use the set screw mounted on the sensor body and tighten it 

 

with the following torque.

 

JES0000:0.06N・m

3)  Wiring
 

  Do not damage the cables. Damaged, forcibly bended, 

 

stretched, winded, load applied or pinched cables will cause

 

fire, electric shock, and/or malfunction due to electric leakage 

 

and/or continuity failure.

 

  Do not apply excessive stress on the cable port of the sensor.

 

  Minimum bending radius of the cable port is R7.

 

  If cables are to move, fix the middle of the cables so that 

 

no stress is applied to the cable port.

4)  Mounting position of the sensor should be adjusted by 
 

checking actual operating state.

●  

Notes on Handling

1)  It should be handled by qualified personnel.
 

  The hydraulic and pneumatic equipment should be handled 

 

and maintained by qualified personnel.

2)  Do not handle or remove the product unless the safety protocols 
 

are ensured.

 ①  The machine and equipment can only be inspected or prepared 
 

when it is confirmed that the preventive devices are in place.

 ②  Before the product is removed, make sure that the above-mentioned 
 

safety measures are in place. Shut off the pressure and power 

 

source, and make sure no pressure exists in the air and hydraulic 

 

circuits.

 ③  After stopping the product, do not remove until the temperature
 

drops.

 ④  Make sure there is no abnormality in the bolts and respective 
 

parts before restarting the machine or equipment.

3)  Do not disassemble or modify.
 

  If the equipment is taken apart or modified, the warranty will be 

 

voided even within the warranty period.

 

Never modify the product as it contains a powerful magnet.

4)  Keep more than one meter away from this product if you have a 
 

heart pacemaker, etc. It may be malfunctioned by strong magnetism.

5)  This sensor is made by ASA Electronics Industry Co. Ltd.

 

Please contact us or ASA Electronics Industry for further inquiries.

1)  Warranty Period
 

  The product warranty period is 18 months from shipment from 

 

our factory or 12 months from initial use, whichever is earlier.

2)  Warranty Scope
 

  If the product is damaged or malfunctions during the warranty 

 

period due to faulty design, materials or workmanship, we will 

 

replace or repair the defective part at our expense.

 

Defects or failures caused by the following are not covered.

 ①  If the stipulated maintenance and inspection are not carried out.
 ②  If the product is used while it is not suitable for use based on 
 

the operatorʼs judgment, resulting in defect.

 ③  If it is used or handled in inappropriate way by the operator.
  (Including damage caused by the misconduct of the third party.)
 ④  If the defect is caused by reasons other than our responsibility.
 ⑤  If repair or modifications are carried out by anyone other than Kosmek, 
 

or without our approval and confirmation, it will void warranty.

 ⑥  Other caused by natural disasters or calamities not attributable to 
 

our company.

 ⑦  Parts or replacement expenses due to parts consumption and 
 

deterioration.

 

(Such as rubber, plastic, seal material and some electric components.)

 

Damages excluding from direct result of a product defect shall be 

 

excluded from the warranty.

●  

Warranty

●  

Maintenance and Inspection

1)  Removal of the Product and Shut-off of Pressure Source
 

  Before the product is removed, make sure that safety measures 

 

and preventive devices are in place. Shut off the pressure and 

 

power source, and make sure no pressure exists in the air and

 

hydraulic circuits.

 

  Make sure there is no abnormality in the bolts and respective 

 

parts before restarting.

2)  Never touch terminals while the power is on.
 

 Otherwise it will cause electric shock, malfunction and damage 

 

to the sensor for air cylinder.

3)  Retightening of Set Screw
 

  When mounting position of the sensor for air cylinder is shifted 

 

due to looseness of set screw, retighten it after adjusting the 

 

mounting position.

4)  Check if the electric cable is damaged or not.
 

  Damaged cables may cause insulation failure. 

 

Replace a sensor for air cylinder or repair the reed if the electric 

 

cable is damaged.

5)  Product Storage
 

 The products should be stored in the cool and dark place 

 

without direct sunshine or moisture.

6)  Please contact us for replacement.

Содержание WPT Series

Страница 1: ...Model WPT Compact and Versatile Use For Transfer Robotic Hand Gripper Change Tool Holding etc High Power Pull Stud Clamp New 2 Larger Sizes Added to the Lineup...

Страница 2: ...r Pressure ON Lock Air Pressure OFF Release Air Pressure OFF Lock Air Pressure ON The pull bolt is pulled in by the piston and steel balls with lock air spring force to complete the locking operation...

Страница 3: ...s of the Pull Stud Clamp can be detected by using with the Sensor for Air Cylinder Refer to P 12 for further information Self locking spring enables to hold a workpiece even when air is accidentally c...

Страница 4: ...Force at 0MPa 1 Cylinder Capacity Lock Side cm3 Release Side Maximum Operating Pressure Minimum Operating Pressure Withstanding Pressure Operating Temperature Range Usable Fluid Weight N N N MPa MPa...

Страница 5: ...Clamping Force Holding Force Air Pressure at 0 5MPa at 0 4MPa at 0 3MPa at 0MPa WPT0600 Clamping Force N 602 497 393 Holding Force N 1234 1019 806 170 3 Clamping Force Holding Force Force that withst...

Страница 6: ...minal Pitch M3 0 5 M4 0 7 M3 0 5 Number of Bolts 4 4 4 1 2 3 1 DWG 1 Bolt Down Mounting DWG 2 Bolt Up Mounting DWG 3 Bolt Up Mounting Note 1 WPT does not include Pull Bolt WPWZ Please order separately...

Страница 7: ...tion DWG 1 Bolt Down Mounting DWG 2 Bolt Up Mounting DWG 3 Bolt Up Mounting M3 0 5 M4 0 7 M3 0 5 Number of Bolts 4 4 4 1 2 3 1 DWG 1 Bolt Down Mounting DWG 2 Bolt Up Mounting DWG 3 Bolt Up Mounting No...

Страница 8: ...P1 9 0 N m High Power Pull Stud Clamp WPT0800 Pull Bolt WPWZ800 P1 Model No WPT0800 Mounting Direction DWG 1 Bolt Down Mounting DWG 2 Bolt Up Mounting DWG 3 Bolt Up Mounting Mounting Bolt Nominal Pit...

Страница 9: ...WPWZ Please order separately DWG 1 Bolt Down Mounting DWG 2 Bolt Up Mounting DWG 3 Bolt Up Mounting High Power Pull Stud Clamp WPT1000 Pull Bolt WPWZ1000 P1 Model No WPT1000 Mounting Direction DWG 1 B...

Страница 10: ...der to avoid malfunction or breakage of the device 4 Please supply ltered clean dry air Oil supply with a lubricator etc is unnecessary 5 Operating Environment WPT has no function that prevents contam...

Страница 11: ...th tensile strength of A2 70 or greater and tighten the product with the tightening torque listed on P 5 P 8 The tightening torque for pull bolt is shown below Installation failure causes air leakage...

Страница 12: ...intenance and inspection are not carried out If the product is used while it is not suitable for use based on the operator s judgment resulting in defect If it is used or handled in inappropriate way...

Страница 13: ...is small we recommend the 3 wire sensor of the high accuracy sensor for air cylinder model JES0000 02 in order to ensure stable detections Sensor for Air Cylinder model JES The Usage Example of Sensor...

Страница 14: ...n Output Current Current Consumption Response Speed Case Material Indicator Light Withstand Voltage Insulation Resistance Operating Temperature Range Operating Humidity Range Protection Grade Cable Le...

Страница 15: ...d JES0000 02LG JES0000 02LGP 16 8 2 2 8 3 8 4 6 10 4 5 Cylinder Sensor Circuit Max 15mA Blue Cable Black Cable Output Red Brown Cable DC 5 24V Max 80mA Blue Cable Black Cable Output Brown Cable DC 5 2...

Страница 16: ...tters 4 Do not use the product in an environment where it is continuously exposed to coolant or chemical liquid Although IEC standard IP67 structure is satis ed please avoid using sensors in an enviro...

Страница 17: ...efects or failures caused by the following are not covered If the stipulated maintenance and inspection are not carried out If the product is used while it is not suitable for use based on the operato...

Страница 18: ...l 2 First Floor Prestige Center Point Cunningham Road Bangalore 560052 India INDIA BRANCH OFFICE FAX 66 2 300 5133 TEL 66 2 300 5132 Av Santa Fe 103 int 59 Col Santa Fe Juriquilla C P 76230 Queretaro...