background image

JES

WPT

Sensor for Air Cylinder

High-Power 

Pull Stud Clamp

model 

WPT/JES

●  

Notes on Handling

1)  It should be handled by qualified personnel.
 

  The hydraulic and pneumatic equipment should be handled 

 

and maintained by qualified personnel.

2)  Do not handle or remove the product unless the safety protocols 
 

are ensured.

 ①  The machine and equipment can only be inspected or prepared 
 

when it is confirmed that the preventive devices are in place.

 ②  Before the product is removed, make sure that the above-mentioned 
 

safety measures are in place. Shut off the pressure and power 

 

source, and make sure no pressure exists in the air and hydraulic 

 

circuits.

 ③  After stopping the product, do not remove until the temperature
 

drops.

 ④  Make sure there is no abnormality in the bolts and respective 
 

parts before restarting the machine or equipment.

3)  In order to avoid injury, please do not touch the clamp while 
 

it is operating.

4)  When a robot is in operation, make sure the safety of 
 

environment in case of a workpiece detachment.

5)Do not disassemble or modify.
 

  If the equipment is taken apart or modified, the warranty 

 

will be voided even within the warranty period.

 

  Built-in spring is very strong and can be dangerous.

High-Power Pull Stud Clamp

 Cautions・Sensor for Air Cylinder

1)  Warranty Period
 

  The product warranty period is 18 months from shipment from 

 

our factory or 12 months from initial use, whichever is earlier.

2)  Warranty Scope
 

  If the product is damaged or malfunctions during the warranty 

 

period due to faulty design, materials or workmanship, we will 

 

replace or repair the defective part at our expense.

 

Defects or failures caused by the following are not covered.

 ①  If the stipulated maintenance and inspection are not carried out.
 ②  If the product is used while it is not suitable for use based on 
 

the operatorʼs judgment, resulting in defect.

 ③  If it is used or handled in inappropriate way by the operator.
  (Including damage caused by the misconduct of the third party.)
 ④  If the defect is caused by reasons other than our responsibility.
 ⑤  If repair or modifications are carried out by anyone other than Kosmek, 
 

or without our approval and confirmation, it will void warranty.

 ⑥  Other caused by natural disasters or calamities not attributable to 
 

our company.

 ⑦  Parts or replacement expenses due to parts consumption and 
 

deterioration.

 

(Such as rubber, plastic, seal material and some electric components.)

 

Damages excluding from direct result of a product defect shall be 

 

excluded from the warranty.

●  

Warranty

1)  Removal of the Product and Shut-off of Pressure Source
 

  Before the product is removed, make sure that safety measures 

 

and preventive devices are in place. Shut off the pressure and 

 

power source, and make sure no pressure exists in the air and

 

hydraulic circuits.

 

  Make sure there is no abnormality in the bolts and respective 

 

parts before restarting.

2)  Clean the product regularly.
 

 Using the product contaminated with dirt may lead to damage 

 

of the product or detachment of a workpiece due to lack of 

 

gripping force and malfunctioning, etc.

3)  Regularly tighten pipings, mounting bolts, etc. to ensure 
 

proper use.

4)  Make sure there is smooth action and no abnormal noise.

  Especially when it is restarted after left unused for a long 

 

period, make sure it can be operated correctly.

5)  The products should be stored in the cool and dark place 
 

without direct sunshine or moisture.

6)  Please contact us for overhaul and repair.
 

Built-in spring is very strong and can be dangerous.

●  

Maintenance and Inspection

Performance

Curve

External

Dimensions

Installation

Method

Accessory

Sensor for Air Cylinder

Cautions

Model No.

Indication

Specifications

Features

Features

12

11

Action Confirmation Method:Sensor for Air Cylinder

This product (model WPT) is able to detect the locking action and releasing action of Sensor for Air Cylinder (sold separately).

Cautions

Refer to P.13 for detail specifications of JES.

Since the stroke amount of the internal piston of Pull Stud Clamp (model WPT) is small,
we recommend the 3-wire sensor of the high accuracy sensor for air cylinder 
“model JES0000-02□□” in order to ensure stable detections.

Sensor for Air Cylinder

model

 

JES

【The Usage Example of Sensor for Air Cylinder】

Released State

Locked State

Cylinder

Sensor State

Mounting Ex. 

for WPT0600

Mounting Ex. 

for WPT0500

State

Sensor 1

Sensor 2

Sensor 2

Sensor 1

Sensor 2

ON

OFF

ON

Sensor 1

Sensor 1

OFF

The mounting position and direction of the sensor for air cylinder vary depending on the individual product 
differences and the magnetic flux change due to the surrounding environment. Please adjust the position 
of the actual product before use. The sensor for air cylinder may stick out from the installation slot of WPT.

Sensor 2

Содержание WPT Series

Страница 1: ...Model WPT Compact and Versatile Use For Transfer Robotic Hand Gripper Change Tool Holding etc High Power Pull Stud Clamp New 2 Larger Sizes Added to the Lineup...

Страница 2: ...r Pressure ON Lock Air Pressure OFF Release Air Pressure OFF Lock Air Pressure ON The pull bolt is pulled in by the piston and steel balls with lock air spring force to complete the locking operation...

Страница 3: ...s of the Pull Stud Clamp can be detected by using with the Sensor for Air Cylinder Refer to P 12 for further information Self locking spring enables to hold a workpiece even when air is accidentally c...

Страница 4: ...Force at 0MPa 1 Cylinder Capacity Lock Side cm3 Release Side Maximum Operating Pressure Minimum Operating Pressure Withstanding Pressure Operating Temperature Range Usable Fluid Weight N N N MPa MPa...

Страница 5: ...Clamping Force Holding Force Air Pressure at 0 5MPa at 0 4MPa at 0 3MPa at 0MPa WPT0600 Clamping Force N 602 497 393 Holding Force N 1234 1019 806 170 3 Clamping Force Holding Force Force that withst...

Страница 6: ...minal Pitch M3 0 5 M4 0 7 M3 0 5 Number of Bolts 4 4 4 1 2 3 1 DWG 1 Bolt Down Mounting DWG 2 Bolt Up Mounting DWG 3 Bolt Up Mounting Note 1 WPT does not include Pull Bolt WPWZ Please order separately...

Страница 7: ...tion DWG 1 Bolt Down Mounting DWG 2 Bolt Up Mounting DWG 3 Bolt Up Mounting M3 0 5 M4 0 7 M3 0 5 Number of Bolts 4 4 4 1 2 3 1 DWG 1 Bolt Down Mounting DWG 2 Bolt Up Mounting DWG 3 Bolt Up Mounting No...

Страница 8: ...P1 9 0 N m High Power Pull Stud Clamp WPT0800 Pull Bolt WPWZ800 P1 Model No WPT0800 Mounting Direction DWG 1 Bolt Down Mounting DWG 2 Bolt Up Mounting DWG 3 Bolt Up Mounting Mounting Bolt Nominal Pit...

Страница 9: ...WPWZ Please order separately DWG 1 Bolt Down Mounting DWG 2 Bolt Up Mounting DWG 3 Bolt Up Mounting High Power Pull Stud Clamp WPT1000 Pull Bolt WPWZ1000 P1 Model No WPT1000 Mounting Direction DWG 1 B...

Страница 10: ...der to avoid malfunction or breakage of the device 4 Please supply ltered clean dry air Oil supply with a lubricator etc is unnecessary 5 Operating Environment WPT has no function that prevents contam...

Страница 11: ...th tensile strength of A2 70 or greater and tighten the product with the tightening torque listed on P 5 P 8 The tightening torque for pull bolt is shown below Installation failure causes air leakage...

Страница 12: ...intenance and inspection are not carried out If the product is used while it is not suitable for use based on the operator s judgment resulting in defect If it is used or handled in inappropriate way...

Страница 13: ...is small we recommend the 3 wire sensor of the high accuracy sensor for air cylinder model JES0000 02 in order to ensure stable detections Sensor for Air Cylinder model JES The Usage Example of Sensor...

Страница 14: ...n Output Current Current Consumption Response Speed Case Material Indicator Light Withstand Voltage Insulation Resistance Operating Temperature Range Operating Humidity Range Protection Grade Cable Le...

Страница 15: ...d JES0000 02LG JES0000 02LGP 16 8 2 2 8 3 8 4 6 10 4 5 Cylinder Sensor Circuit Max 15mA Blue Cable Black Cable Output Red Brown Cable DC 5 24V Max 80mA Blue Cable Black Cable Output Brown Cable DC 5 2...

Страница 16: ...tters 4 Do not use the product in an environment where it is continuously exposed to coolant or chemical liquid Although IEC standard IP67 structure is satis ed please avoid using sensors in an enviro...

Страница 17: ...efects or failures caused by the following are not covered If the stipulated maintenance and inspection are not carried out If the product is used while it is not suitable for use based on the operato...

Страница 18: ...l 2 First Floor Prestige Center Point Cunningham Road Bangalore 560052 India INDIA BRANCH OFFICE FAX 66 2 300 5133 TEL 66 2 300 5132 Av Santa Fe 103 int 59 Col Santa Fe Juriquilla C P 76230 Queretaro...

Отзывы: