 (3)

Fix the accessory cable with the Interconnection cable block.

 (4)

 

Confirm the fixing of the accessory cable is ok.

(2)

Take off the block for Interconnection cable, then put the core of the power wire to the terminal and 

     fix it according to the diagrams pasted to indoor and outdoor unit separately.

 (5)

Fix the cover for Interconnection cable on.

(1)

Take off the cover for Interconnection cable of outdoor unit.

Diagram for installation of Interconnection cable

 ( please see the pasted diagram instruction on the body first)

Cooling & Heating

Cooling Only 

Connetting 
indoor unit

Connetting 
power

Connetting 
outdoor unit

Connetting 
indoor unit

Connetting 
power

Indoor Unit

3 N

1 2

L

Connetting 
outdoor unit

Indoor Unit

N

1 L

Outdoor Unit

N

1 L N

L

Outdoor Unit

3 N

1 2

L N

L

1 N

1 2 3N

Cooling & Heating

1 2 3N

 Cooling Only

1N

Connetting outdoor unit

Connetting indoor unit

1 L

N

1 L

N

Indoor Unit

Outdoor Unit

09K,12K,15K,18K indoor interconnection cable sketch map

22K,24K indoor and outdoor  interconnection cable sketch map

09K,12K,15K,18K outdoor  interconnection cable sketch map

Split frequency conversion air conditioner interconnection cable
 means(Heating and cooling was as same as Cooling  

Installation Instructions

Interconnection Cable

 Circuit Diagram

 Cooling Only

Cooling & Heating

Содержание ERA series

Страница 1: ......

Страница 2: ...he remote controller is preset to automatically the symbol will flash from COOL and HEAT alternatively COOL symbol COOL mode will be set COOL mode Auto restart Presetting optional The appliance is pre...

Страница 3: ...touch the operation buttons when your hands are wet Notes For the purpose of innovation and improvement above products are subject to change without prior notice Do not put any object on the outdoor...

Страница 4: ...oner you have selected Air Intake Air Intake Air Outlet Louver Vertical Adjustment Louver Horizontal Adjustment Air Filter Remote Controller Front Panel Emergency Panel Display Panel Note Condensate w...

Страница 5: ...It lights up during the set sleep function It lights up when power supply is on Signal Receives Receive signal from the remote controller It lights up during the set time Timer Indicator Run Indicator...

Страница 6: ...ype of operation mode FEEL COOLING DRY FAN AND HEATING FEEL mode can select the operation mode such as COOL DRY FAN HEAT automatically depending on the room temperature Only for Heat Pump Used to sele...

Страница 7: ...conditioner aim the remote controller to the signal receptor The remote controller will operate the air conditioner at a distance of up to 7m when pointing at signal receptor of indoor unit Remote con...

Страница 8: ...Press the MODE select button repeatedly until the mode indicator on the display points at FEEL mode 1 2 FEEL mode automatically selects the operation mode DRY FAN COOL depending on the current room te...

Страница 9: ...to set a switch on timer press again the setting will be cancel When the Remote Controller is ON press the TIMER button to set a switch on timer press again the setting will be cancel Press UP and DOW...

Страница 10: ...Never sprinkle water onto the indoor unit Reinstall and shut the front panel Reinstall and shut the front panel by pressing position b downward If the dirt is conspicuous wash it with a solution of de...

Страница 11: ...es the noise level Protection Features of protector Inspection After using for a long time the air conditioner should be inspected on the following items Overheat of the power supply cord and plug or...

Страница 12: ...ill be abnormal At this time disconnect from the power supply by turning off the circuit breaker and connect back 2 3 seconds later Changing mode during operation will delay start up for 3 minutes Thi...

Страница 13: ...er 150 mm should be over 150mm should be over 2000mm should be over 300mm Installation must be performed in accordance with the national wiring standards by authorized personnel only Above figure is o...

Страница 14: ...le near the air outlet and air can be easily blown to every corner Where piping and wall hole can be easily arranged Keep the required space from the unit to the ceiling and wall according to the inst...

Страница 15: ...Drill a hole on the wall The hole should tilt a little downward toward outside Decide the position of hole for piping according to the location of mounting plate 2 Drill a Hole for Piping Keep the mou...

Страница 16: ...ion tube Power cord 1 for heat pump Power cord Defrost cable for heat pump Drain hose prepared by user A Insert the pipe fixer to the slot B Press to hook the pipe fixer onto the base Base Base Base P...

Страница 17: ...circuit specifically for the air conditioner As for the method of wiring refer to the circuit diagram posted on the inside of the access door 2 Comfirm that the cable thickness is as specified in the...

Страница 18: ...ct the condensate water Just install the drain port and rubber washer to the chassis of the outdoor unit then connect a drain hose to the port as the right figure shown The air which contains moisture...

Страница 19: ...g Only Connetting indoor unit Connetting power Connetting outdoor unit Connetting indoor unit Connetting power Indoor Unit 3 N 1 2 L Connetting outdoor unit Indoor Unit N 1 L Outdoor Unit N 1 L N L Ou...

Страница 20: ...ppliance to a double pole switching device with contact separation of at least 3 mm placed in an accessible position even after installation NOTE Test Running Connect to the power source check if the...

Страница 21: ...2366 67 823 2370 72 Sales 02 823 1580 24 Hour Hotlione 02 843 4343 loc 21544 Fax 02 823 6995 Sales 02 823 6999 Service BRANCH Office CEBU DAVAO J P Cabaguio Avenue A Cortez Avenue Mandaue City Davao...

Отзывы: