II. Incoming Inspection

 

 

Kooltronic Air Conditioners are designed, built and packaged to withstand the shock and vibration normally 
associated with shipment by common carriers. Occasionally improper handling during shipping causes damage. 
Such handling could include unbanding of palletized shipments, failing to respect 

"This Side Up"

 arrows, rough 

handling, falling off conveyors, excessive vibration, crushing, etc. Therefore, a thorough inspection should be 
done upon receipt of all shipments. Any carton tears, dents, scratches, loose articles or evidence of oil are signs 
of damage and should be noted on the Freight Bill. Cartons should be opened promptly and the units inspected 
for CONCEALED DAMAGE. Kooltronic Air Conditioners must be delivered in the proper mounting position to 
assure that damage to the compressor has not occurred during shipping. Any Kooltronic Air Conditioner that is 
delivered removed from the banded pallet, lying down or double stacked should be refused. 

 
An immediate claim MUST be filed with the freight carrier and an inspection requested. Retain all packing 
materials. Kooltronic cannot assume responsibility for Consignee's failure to file a timely freight claim. 

 

III. Product Handling:

 

 

1) Do not attempt to operate your Kooltronic Air Conditioner until you read and  thoroughly understand this 

Manual. See section 

VI PRE-INSTALLATION TESTING. 

 
2) Before operating the Kooltronic Air Conditioner be certain that it is placed in its correct mounting position. 

This Air Conditioner is designed to operate in a vertical position only. 

This placement must be done 

a minimum of 5 minutes prior to operating in order to allow the compressor oil to drain to the compressor 
sump area.  

 

                                        CAUTION

 

 
 
 
 
 
 

 

3) Before operating this unit, all electrical wiring must be checked to assure the proper connection to the correct 

power source. Minimum circuit ampacity should be at least 125% of the amperage found on the nameplate 
for the corresponding voltage. Do not exceed the maximum fuse size found on the nameplate. 

 
4) We do not recommend that Air Conditioners be shipped to their final destination attached to an enclosure. In 

the event that the Air Conditioner needs to be shipped attached to an enclosure it is strongly recommended 
that proper support be provided for the Air Conditioner. Excessive vibration can occur if Air Conditioners are 
not properly supported when shipped on enclosures, increasing the potential for internal damage and voiding 
the warranty. 

 

5)

PROCEDURE FOR PROPER PACKING AND SHIPMENT OF KOOLTRONIC AIR 
CONDITIONERS: 

 

Keep Air Conditioner in proper upright position indicated by arrow markers. 

Pack Air Conditioner in an appropriate carton (preferably original carton if possible), with adequate 
internal protective packaging, making sure carton is marked and is kept in correct upright position. 

For local, controlled transportation, strap carton to a secure part of truck to prevent falling or 
sliding, minimize vibration, etc. 

For common carrier shipment, band unit(s) securely to a pallet. Unpalleted shipment risks 
severe damage which voids the warranty.

Kooltronic Air Conditioners must be operated in their proper mounting position. If attempts are 

made to operate a unit that is not in its designed mounting position, permanent compressor 

damage will occur. This action will void the warranty. To avoid compressor damage do not tip the 

unit more than 45° from its proper mounting position.

Содержание TRIMLINE KA4C2.0NP17L

Страница 1: ...L BE READ AND UNDERSTOOD THOROUGHLY KOOLTRONIC INC 30 Pennington Hopewell Road Pennington NJ 08534 609 466 3400 FAX 609 466 1114 www kooltronic com TRIMLINE KA4C2 0NP17L with Serial Numbers B17A0456 a...

Страница 2: ...fic model page of the Kooltronic website I Introduction Kooltronic Air Conditioners are designed to provide a cool dehumidified environment for your electronic components There are models to fit virtu...

Страница 3: ...prior to operating in order to allow the compressor oil to drain to the compressor sump area CAUTION 3 Before operating this unit all electrical wiring must be checked to assure the proper connection...

Страница 4: ...ect type or amount of refrigerant will adversely affect performance and may damage the unit r Make sure that these parameters are met Failure to do so may result in permanent damage to the unit ALL MO...

Страница 5: ...bs the heat and is then discharged to the environment When the Kooltronic Air Conditioner is properly sized it should operate constantly and maintain 75 F to 115 F enclosure temperature depending on t...

Страница 6: ...re the new set point value push the SET key again or wait 10 seconds HOW TO CHANGE A PARAMETER VALUE To change a parameter s value operate as follows 1 Enter the Programming mode by pressing the SET p...

Страница 7: ...p code 7 0 65535 rEL Software release 0 rSE Real set point 0 onF on off key enabling ES PbC Kind of probe ntc Adr Serial address 1 1 247 HES Differential for energy saving 0 F 54 54 rrd Regulation res...

Страница 8: ...te the factory setting is 75o F Refer to page 6 for instructions on adjustment of the thermostat 8 Operate the air conditioner for approximately ten 10 minutes During this period no unusual noise or v...

Страница 9: ...washers NOTE Make sure the press studs are inserted with heads toward you Tighten nuts securely 4 To facilitate easy mounting the three screws located on each side of the unit should be backed out en...

Страница 10: ...102 4 1 12 28 6 0 75 19 0 M TAB MOUNTING PLAN 5 61 142 5 5 61 142 5 50 12 7 16 50 419 1 3 12 79 2 50 12 7 8 12 206 4 8 12 206 4 8 312 7 9 DIA HOLES 5 78 146 8 38 9 7 5 12 130 2 3 75 95 2 6 38 162 1 1...

Страница 11: ...9 07 230 3 5 66 143 7 45 11 4 9 90 251 5 5 96 151 4 2 03 51 6 59 15 0 3 30 83 7 14 20 360 8 6 20 157 6 95 24 0 1 2 3 4 Drawings and Dimensions KA4C2 0NP17L Dimensions inches are for reference only and...

Страница 12: ...Short Cycle Protector Filter Low Ambient Kit NEMA 12 Rating Maintained UL50 Programmable Temperature Alarm Programmable Thermostat UL CUL Listed Accessories and Options Filter Recoating Adhesive Inte...

Страница 13: ...nd Service Kooltronic Air Conditioners feature an easily removable inlet filter to facilitate necessary cleaning CAUTION 1 Lift the filter using the attached tab to clear the lower filter retainer 2 A...

Страница 14: ...erformance and built for reliability They are designed to require only routine maintenance If your air conditioner should require warranty service please contact Kooltronic If you require service out...

Страница 15: ...r Clean Coil difference between return and Coil clogged supply air is less than 10 F Evaporator Blower Condenser Loss of Refrigerant Locate and repair leak Blower and Compressor are running Ice on Eva...

Страница 16: ...eceived by customer Number of parts to be returned Product description model and serial number Reason for return Action requested Contact name telephone FAX numbers and e mail address Pack unit in a s...

Отзывы: