background image

Technical Data

9

KA4C2NP33L

2000

125/50

115/100

60/50

12.8

90

KA4C2NP33L56

2000

125/50

115

50/60*

12.8

90

K2A4C2NP33L

2000

120/50

230/200

60/50

5.5

90

K2A4C2NP33L5

2000

120/50

230

50

5.8

90

KA4C3NP33L

3000

125/50

115/100

60/50

12.8

90

KA4C3NP33L56

3000

125/50

115

50/60*

12.8

90

K2A4C3NP33L

3000

120/50

230/200

60/50

5.5

90

K2A4C3NP33L5

3000

120/50

230

50

5.8

90

KA4C4NP33L

4000

125/50

115/100

60/50

12.8

90

KA4C4NP33L56

4000

125/50

115

50/60*

12.8

90

K2A4C4NP33L

4000

120/50

230/200

60/50

5.5

90

K2A4C4NP33L5

4000

120/50

230

50

5.8

90

KA4C5NP33L

5000

125/50

115/100

60/50

12.8

90

KA4C5NP33L56

5000

125/50

115

50/60*

12.8

90

K2A3C5NP33L

5000

125/50

230/200

60/50

7.0

90

K2A3C5NP33L5

5000

125/50

230

50

6.5

90

**

Ambient

**

Approximate

BTU/H

Temp. °F

Running

Weight

Model

Rating

Max./Min.

Volts

Hz

Amps

(lbs.)

"

"

*

Switchable. Switch is internally-mounted for security.

** Rating shown is for operation at maximum ambient temperature.

"

115V, 60 Hz and 230V, 60 Hz models also perform at full capacity when operated
at 100V, 50 Hz or 200V, 50 Hz respectively. No transformer is required.

Major Component Replacements

KA4C_NP33

K2A4C_NP33

K2A3C_NP33

2,000-5,000 BTU

2,000-4,000 BTU

5,000 BTU

Part

Part Number

Part Number

Part Number

Compressor

0665-101

0665-107

0665-33

Compressor Capacitor

N/A

N/A

0452-12

Condenser Blower Motor

0261-08

0261-54

0261-54

Condenser Blower Motor Capacitor

0452-03

0452-06

0452-06

Condenser Blower Assembly

609033-00-124

609033-00-125

609033-00-125

Evaporator Blower Motor

0261-97

950-005-89

950-005-89

Evaporator Blower Motor Capacitor

0452-03

0452-03

0452-03

Evaporator Blower Assembly

609033-00-93

609033-00-92

609033-00-92

Filter

12251F

12251F

12251F

NOTE: Part Numbers shown are for 60Hz/1Ø. For 50Hz consult Kooltronic.

Standard Features

Built-in Condensate Evaporator
CFC-Free or Low-ODP Refrigerant
EMI/RFI Suppressor
Low Temperature Control Thermostat
M/TAB Mounting System
NEMA 12 Rating Maintained (UL50)
Reversible Condenser Outlet Blower
UL /CUL Listed

Units in BOLD are current standard products. Other units are prior product offerings and shown for reference only.

Содержание TRIMLINE K2A3C5NP33L

Страница 1: ...L CAUTION BEFORE INSTALLING AND USING THIS AIR CONDITIONER IT IS IMPORTANT THAT THIS MANUAL BE READ AND UNDERSTOOD THOROUGHLY KOOLTRONIC INC 30 Pennington Hopewell Road Pennington NJ 08534 609 466 340...

Страница 2: ...ntroduction Kooltronic Air Conditioners are designed to provide a cool dehumidified environment for your electronic components There are models to fit virtually all sizes and shapes of electronics enc...

Страница 3: ...a horizontal position only This placement must be done a minimum of 5 minutes prior to operating in order to allow the compressor oil to drain to the compressor sump area CAUTION 3 Before operating t...

Страница 4: ...incorrect type or amount of refrigerant will adversely affect performance and may damage the unit Make sure that these parameters are met Failure to do so may result in permanent damage to the unit MO...

Страница 5: ...closure moisture accumulated on the evaporator coil is collected in the condensate tray and released to the ambient air through the drain tube or the condensate evaporator The heat removed through the...

Страница 6: ...TO OPERATE THE THERMOSTAT MAY NEED ADJUSTMENT Adjust Thermostat setting downward until compressor and condenser blower start Note factory setting first If unit is tested without heat load be sure to r...

Страница 7: ...AB 6 Insert the remaining 10 32 screws and seal washers supplied by Kooltronic through the Air Conditioner side panel and into the M TAB To avoid misalignment of parts do not tighten any of the screws...

Страница 8: ...Air Out WARM AIR RETURN FROM ENCLOSURE Enclosure opening should be located as high as possible within this area and equal or exceed size of cool air outlets COOL AIR OUTLET TO ENCLOSURE Drawings and D...

Страница 9: ...models also perform at full capacity when operated at 100V 50 Hz or 200V 50 Hz respectively No transformer is required Major Component Replacements KA4C_NP33 K2A4C_NP33 K2A3C_NP33 2 000 5 000 BTU 2 0...

Страница 10: ...HEATER T STAT OPTIONAL HEATER 55 T STAT 75 BU Y R THERMAL CUTOUT BU R RELAY O L C S R BK WE 2 1 CAP K2A4C_NP33 ON OFF SWITCH FOR UL LISTED UNITS CONDENSER BLR MTR 1 0 8 6 RELAY ADDITIONAL OPTIONS 1 AI...

Страница 11: ...Continued operation under these conditions will cause damage shorten compressor life and void the warranty A Filter Removal and Service Kooltronic Air Conditioners feature an easily removable inlet f...

Страница 12: ...ss valve fails it is strongly recommended that the Air Conditioner be returned to Kooltronic for service D Refrigerant Loss Kooltronic Air Conditioners are subjected to a series of tests to detect ref...

Страница 13: ...ntrol Replace Thermostat or Relay Thermostat defective when applicable Failed Compressor Replace Compressor Ice on Evaporator Coil Insufficient Heat Load or Unit Contact Kooltronic Oversized for Appli...

Страница 14: ...unted Cooled Mini NP33 Horizontal Accessories and Options HS P24 P47 NP36 Rack Top Panel MM NM P28 P52 NP47 Mounted Mounted Mounted SM NP17 P36 P59 NP59 H V HT WP Adapter Plate for Rack Mounting N A N...