CONDENSATE EVAPORATOR KIT: This device
attaches to bottom of Air Conditioner. Condensate is col-
lected, vaporized and discharged to ambient.

COOLING EFFECT DETECTOR: A thermostat is
mounted inside the cabinet and attached to a sensor in
the warm air return. When the air temperature increases
to a set point, a signal is sent to a terminal block.
Requires user-installed wiring to a warning device.

EXCESS PRESSURE DETECTOR: Monitors head or
condensing pressure within the Air Conditioner. When the
pressure reaches an unsafe level a switch sends a signal
to the terminal block. Requires user-installed wiring to a
warning device.

LOW TEMPERATURE CONTROL: Recommended in
situations of extremely low ambient temperatures and/or
low internal loads. At a pre-set return air temperature, the
Thermostat shuts down the unit, except for the
evaporator blower, for continuous cabinet air circulation.

SHORT CYCLE PROTECTOR: Protects the compressor
from damage due to harmful short cycling after a power
interruption. Protector keeps compressor off for 5 to 6
minutes before resumption of operation.

WEATHER PROTECTION KIT: For outdoor installations
subject to invasion by rain, snow or windblown dirt,
special deflectors shield the condenser air inlet and
outlet ports.

Air Cooled

Water

Panel Mounted

Cooled

Mini

NP33

Horizontal

Accessories and Options

HS

P24

P47

NP36

Rack

Top

Panel

MM

NM

P28

P52

NP47 Mounted Mounted

Mounted

SM

NP17

P36

P59*

NP59

(H & V)

(HT)

(WP)

Adapter Plate for Rack Mounting

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Air Deflectors

N/A

Airflow Switch

E

N/A

Compressor Heater

Condenser Access Panel

N/A

N/A

N/A

N/A

N/A

N/A

Condensate Evaporator Kit

F

Std.

Std.

B

Std.

Cooling Effect Detector

A

Deep Drain Pan Kit

X

N/A

C

N/A

Std.

Std.

Excess Pressure Detector

A

D

Filter Recoating Adhesive

N/A

Filters for replacement

N/A

Internal Corrosion Resistance

Lifting Eyes

N/A

N/A

Low Airflow Detector

E

N/A

Low Ambient Kit

X

X

X

X

K

X

X

N/A

Low Temperature Control

A

Std.

Std.

M/TAB**

N/A

Std.

H

N/A

N/A

Std.

N/A

N/A

N/A

Mounting Hinge

N/A

J

N/A

N/A

N/A

Rear Condenser Air Inlet Panel

Std.

Std.

H

Std.

Std.

N/A

N/A

N/A

Refrigerant Charging Kit

Short Cycle Protector

A

Special External Paint Finishes

Special Line Cord or Connectors

Surge Suppressor

Std.

Std.

Switchable Power (50/60Hz)

Unit Heaters

X

G

Weather Protection Kit

N/A

X. Accessories

Available

*

18,000-22,000 BTU/H P59 accessories
and options same as NP59

**

Mounting Template & Assembly
Bracket

X

Not available due to design 
configuration

A

Micro-Mini has internal
space available for only one
of these options. All others
are mounted externally.

B

Standard on H models

C Standard on P24
D Not available on P24 series

E

N/A on Micro-Mini

F

Standard on Super-Mini

G N/A on Narrow-Mini
H N/A on HS
J

Available on NP17

K

Available on NP59

Содержание TRIMLINE K2A3C5NP33L

Страница 1: ...L CAUTION BEFORE INSTALLING AND USING THIS AIR CONDITIONER IT IS IMPORTANT THAT THIS MANUAL BE READ AND UNDERSTOOD THOROUGHLY KOOLTRONIC INC 30 Pennington Hopewell Road Pennington NJ 08534 609 466 340...

Страница 2: ...ntroduction Kooltronic Air Conditioners are designed to provide a cool dehumidified environment for your electronic components There are models to fit virtually all sizes and shapes of electronics enc...

Страница 3: ...a horizontal position only This placement must be done a minimum of 5 minutes prior to operating in order to allow the compressor oil to drain to the compressor sump area CAUTION 3 Before operating t...

Страница 4: ...incorrect type or amount of refrigerant will adversely affect performance and may damage the unit Make sure that these parameters are met Failure to do so may result in permanent damage to the unit MO...

Страница 5: ...closure moisture accumulated on the evaporator coil is collected in the condensate tray and released to the ambient air through the drain tube or the condensate evaporator The heat removed through the...

Страница 6: ...TO OPERATE THE THERMOSTAT MAY NEED ADJUSTMENT Adjust Thermostat setting downward until compressor and condenser blower start Note factory setting first If unit is tested without heat load be sure to r...

Страница 7: ...AB 6 Insert the remaining 10 32 screws and seal washers supplied by Kooltronic through the Air Conditioner side panel and into the M TAB To avoid misalignment of parts do not tighten any of the screws...

Страница 8: ...Air Out WARM AIR RETURN FROM ENCLOSURE Enclosure opening should be located as high as possible within this area and equal or exceed size of cool air outlets COOL AIR OUTLET TO ENCLOSURE Drawings and D...

Страница 9: ...models also perform at full capacity when operated at 100V 50 Hz or 200V 50 Hz respectively No transformer is required Major Component Replacements KA4C_NP33 K2A4C_NP33 K2A3C_NP33 2 000 5 000 BTU 2 0...

Страница 10: ...HEATER T STAT OPTIONAL HEATER 55 T STAT 75 BU Y R THERMAL CUTOUT BU R RELAY O L C S R BK WE 2 1 CAP K2A4C_NP33 ON OFF SWITCH FOR UL LISTED UNITS CONDENSER BLR MTR 1 0 8 6 RELAY ADDITIONAL OPTIONS 1 AI...

Страница 11: ...Continued operation under these conditions will cause damage shorten compressor life and void the warranty A Filter Removal and Service Kooltronic Air Conditioners feature an easily removable inlet f...

Страница 12: ...ss valve fails it is strongly recommended that the Air Conditioner be returned to Kooltronic for service D Refrigerant Loss Kooltronic Air Conditioners are subjected to a series of tests to detect ref...

Страница 13: ...ntrol Replace Thermostat or Relay Thermostat defective when applicable Failed Compressor Replace Compressor Ice on Evaporator Coil Insufficient Heat Load or Unit Contact Kooltronic Oversized for Appli...

Страница 14: ...unted Cooled Mini NP33 Horizontal Accessories and Options HS P24 P47 NP36 Rack Top Panel MM NM P28 P52 NP47 Mounted Mounted Mounted SM NP17 P36 P59 NP59 H V HT WP Adapter Plate for Rack Mounting N A N...