background image

9

Standard Features 

 

Built-in Condensate Evaporator 
CFC-Free Refrigerant 
Filter 
Low Temperature Control Thermostat 
NEMA 12 Rating Maintained (UL50) 
UL/CUL Listed 

Accessories and Options 

 

Compressor Short Cycle Protector 
Enclosure Heater 
Filter Recoating Adhesive 
High-Capacity Condensate Evaporator 
Internal Corrosion Protection 
Lifting Eyes 
Low Airflow Detector 
Low Ambient Kit 
Remote Thermostat Relay 
Replacement Filters 
Special materials or finishes  
Special motors, line cords or connectors 
Stainless or Aluminum Shell 
Temperature Alarm 
Weather Protection Kit

Technical Data

KA4C2NP33L                    2000              125/50                   115/100                  60/50               12.8                 90 
KA4C2NP33L56                2000              125/50                          115                  50/60*              12.8                 90 
K2A4C2NP33L                  2000              120/50                   230/200                  60/50                 5.5                 90 
K2A4C2NP33L5                2000              120/50                          230                       50                 5.8                 90 

 

KA4C3NP33L                    3000              125/50                   115/100                  60/50               12.8                 90 
KA4C3NP33L56                3000              125/50                          115                  50/60*              12.8                 90 
K2A4C3NP33L                  3000              120/50                   230/200                  60/50                 5.5                 90 
K2A4C3NP33L5                3000              120/50                          230                       50                 5.8                 90 

 

KA4C4NP33L                    4000              125/50                   115/100                  60/50               12.8                 90 
KA4C4NP33L56                4000              125/50                          115                  50/60*              12.8                 90 
K2A4C4NP33L                  4000              120/50                   230/200                  60/50                 5.5                 90 
K2A4C4NP33L5                4000              120/50                          230                       50                 5.8                 90

 

 

KA4C5NP33L                    5000              125/50                   115/100                  60/50               12.8                 90 
KA4C5NP33L56                5000              125/50                          115                  50/60*              12.8                 90 
K2A3C5NP33L                  5000              125/50                   230/200                  60/50                 7.0                 90 
K2A3C5NP33L5                5000              125/50                          230                       50                 6.5                 90

                                            **                Ambient                                                                         **          Approximate 
                                        BTU/H            Temp. °F                                                                   Running         Weight 

Model                               Rating           Max./Min.                  Volts                       Hz               Amps             (lbs.)

 

*    Switchable. Switch is internally-mounted for security. 
**  Rating shown is for operation at maximum ambient temperature. 

 115V, 60 Hz and 230V, 60 Hz models also perform at full capacity when operated at 100V, 50 Hz or 200V, 50 Hz respectively. No transformer is required.

Major Component Replacements 

 

                                                                KA4C_NP33           K2A4C_NP33        K2A3C_NP33 

                                                            2,000-5,000 BTU      2,000-4,000 BTU        5,000 BTU 

Part                                                         Part Number            Part Number         Part Number 

Compressor                                             0665-101                  0665-107                0665-33 
Compressor Capacitor                            N/A                            N/A                         0452-12 
Condenser Blower Motor                        0261-08                    0261-54                  0261-54 
Condenser Blower Motor Capacitor        0452-03                    0452-03                  0452-03 
Condenser Blower Assembly                  7083-00-10                7082-00-02             7082-00-02 
Evaporator Blower Motor                        0261-97                    950-005-89            950-005-89

 

Evaporator Blower Motor Capacitor        0452-03                    0452-03                  0452-03 
Evaporator Blower Assembly                  609033-00-93           609033-00-92        609033-00-92 
Filter                                                        12251F                     12251F                   12251F 

Содержание L17A3573

Страница 1: ...AUTION BEFORE INSTALLING AND USING THIS AIR CONDITIONER IT IS IMPORTANT THAT THIS MANUAL BE READ AND UNDERSTOOD THOROUGHLY KOOLTRONIC INC 30 Pennington Hopewell Road Pennington NJ 08534 609 466 3400 F...

Страница 2: ...age of the Kooltronic website I Introduction Kooltronic Air Conditioners are designed to provide a cool dehumidified environment for your electronic components There are models to fit virtually all si...

Страница 3: ...prior to operating in order to allow the compressor oil to drain to the compressor sump area CAUTION 3 Before operating this unit all electrical wiring must be checked to assure the proper connection...

Страница 4: ...ect type or amount of refrigerant will adversely affect performance and may damage the unit r Make sure that these parameters are met Failure to do so may result in permanent damage to the unit ALL MO...

Страница 5: ...ure accumulated on the evaporator coil is collected in the condensate tray and released to the ambient air through the drain tube or the condensate evaporator The heat removed through the evaporator c...

Страница 6: ...be delayed until the system pressures rise 10 Operate the air conditioner for approximately ten 10 minutes During this period no unusual noise or vibration should be evident Both the evaporator and co...

Страница 7: ...TAB 6 Insert the remaining 10 32 screws and seal washers supplied by Kooltronic through the Air Conditioner side panel and into the M TAB To avoid misalignment of parts do not tighten any of the scre...

Страница 8: ...8 Drawings and Dimensions NP33 SERIES Other drain outlets are available contact KOOLTRONIC Dimensions inches are for reference only and are subject to change...

Страница 9: ...12 8 90 K2A4C4NP33L 4000 120 50 230 200 60 50 5 5 90 K2A4C4NP33L5 4000 120 50 230 50 5 8 90 KA4C5NP33L 5000 125 50 115 100 60 50 12 8 90 KA4C5NP33L56 5000 125 50 115 50 60 12 8 90 K2A3C5NP33L 5000 125...

Страница 10: ...nd the compressor will continue to cycle on and off Continued operation under these conditions will cause damage shorten compressor life and void the warranty A Filter Removal and Service Kooltronic A...

Страница 11: ...pass valve fails it is strongly recommended that the Air Conditioner be returned to Kooltronic for service D Refrigerant Loss Kooltronic Air Conditioners are subjected to a series of tests to detect r...

Страница 12: ...Control Replace Thermostat or Relay Thermostat defective when applicable Failed Compressor Replace Compressor Ice on Evaporator Coil Insufficient Heat Load or Unit Contact Kooltronic Oversized for Ap...

Страница 13: ...eceived by customer Number of parts to be returned Product description model and serial number Reason for return Action requested Contact name telephone FAX numbers and e mail address Pack unit in a s...