Technical Data

NP47 Series

KA4C4NP47R

4000

125/50

115/100

60/50

16.5

150/160

KA4C4NP47R56

4000

125/50

115

50/60*

15.5/16.5

150/160

K2A4C4NP47L

4000

125/50

230/200

60/50

8.5

150/160

K2A4C4NP47L5

4000

125/50

230

50

7.6

150/160

KA4C5NP47R

5000

125/50

115/100

60/50

16.5

150/160

KA4C5NP47R56

5000

125/50

115

50/60*

15.5/16.5

150/160

K2A4C5NP47L

5000

125/50

230/200

60/50

8.5

150/160

K2A4C5NP47L5

5000

125/50

230

50

7.6

150/160

KA4C6NP47R

6000

125/50

115/100

60/50

16.5

150/160

KA4C6NP47R56

6000

125/50

115

50/60*

15.5/16.5

150/160

K2A4C6NP47L

6000

125/50

230/200

60/50

8.5

150/160

K2A4C6NP47L5

6000

125/50

230

50

7.6

150/160

KA4C7NP47R

7000

125/50

115/100

60/50

16.5

150/160

KA4C7NP47R56

7000

125/50

115

50/60*

15.5/16.5

150/160

K2A4C7NP47L

7000

125/50

230/200

60/50

8.5

150/160

K2A4C7NP47L5

7000

125/50

230

50

7.6

150/160

KA3C8NP47R

8000

120/50

115/100

60/50

19.2/18.6

150/160

KA3C8NP47R56

8000

120/50

115

50/60*

18.6/19.2

150/160

K2A4C8NP47L

8000

125/50

230/200

60/50

11.8

150/160

K2A4C8NP47L5

8000

125/50

230

50

10.0

150/160

KA3C9NP47R

9000

120/50

115/100

60/50

19.2/18.6

150/160

KA3C9NP47R56

9000

120/50

115

50/60*

18.6/19.2

150/160

K2A4C9NP47L

9000

125/50

230/200

60/50

11.8

150/160

K2A4C9NP47L5

9000

125/50

230

50

10.0

150/160

KA3C10NP47R

10000

120/50

115/100

60/50

19.2/18.6

150/160

KA3C10NP47R56

10000

120/50

115

50/60*

18.6/19.2

150/160

K2A4C10NP47L

10000

125/50

230/200

60/50

11.8

150/160

K2A4C10NP47L5

10000

125/50

230

50

10.0

150/160

KA3C12NP47R

12000

120/50

115/100

60/50

19.2/18.6

150/160

KA3C12NP47R56

12000

120/50

115

50/60*

18.6/19.2

150/160

K2A4C12NP47L

12000

125/50

230/200

60/50

11.8

150/160

K2A4C12NP47L5

12000

125/50

230

50

10.0

150/160

**

Ambient

**

Approximate

BTU/H

Temp. °F

Running

Weight

Model

Rating

Max./Min.

Volts

Hz

Amps

(lbs.)

*

Switchable. Switch is internally-mounted for security.

** Rating shown is for operation at maximum ambient temperature.

115V, 60 Hz and 230V, 60 Hz models also perform at full capacity when operated
at 100V, 50 Hz or 200V, 50 Hz respectively.  No transformer is required.

Major Component Replacements

KA4C_NP47R

KA3C_NP47R

4000-7000 BTU/H

8000-12000 BTU/H

Part

Part Number

Part Number

Compressor

0665-103

0665-42

Compressor Capacitor

N/A

0452-32

Condenser Blower Motor

0261-287

0261-287

Condenser Blower Motor Capacitor

0452-03

0452-03

Condenser Blower Assembly

8060-00-11

8060-00-11

Evaporator Blower Motor

0261-08

0261-08

Evaporator Blower Motor Capacitor

0452-03

0452-03

Evaporator Blower Assembly

6015-00-129

6015-00-129

Filter

12251F

12251F

NOTE: Part Numbers shown are for 115v/60Hz/1Ø. For 230v/60Hz/1Ø and all 50Hz consult Kooltronic.

Содержание K2A4C10NP47L

Страница 1: ...TANT THAT THIS MANUAL BE READ AND UNDERSTOOD THOROUGHLY KOOLTRONIC INC 30 Pennington Hopewell Road Pennington NJ 08534 609 466 3400 FAX 609 466 1114 TRIMLINE NP47 SERIES 7 000 10 000 BTU H 900 034 08...

Страница 2: ...ction Kooltronic Air Conditioners are designed to provide a cool dehumidified environment for your electronic components There are models to fit virtually all sizes and shapes of electronic enclosures...

Страница 3: ...position All Air Conditioners containing an MM NM P or V as part of the model number are designed to operate in a vertical position only All Air Conditioners containing an H RT or RM in the model num...

Страница 4: ...ements y Use of incorrect type or amount of refrigerant will adversely affect performance and may damage the unit r Make sure that these parameters are met Failure to do so may result in permanent dam...

Страница 5: ...nger The warm air inside the enclosure is drawn through the evaporator coil where it is cooled dehumidified and returned Any enclosure moisture accumulated on the evaporator coil is collected in the c...

Страница 6: ...ower will be delayed until the system pressures rise 10 Operate the air conditioner for approximately ten minutes During this period no unusual noise or vibration should be evident Both the evaporator...

Страница 7: ...B by sliding the studs located on each side panel into the slots on the M TAB 6 Insert the remaining 10 32 screws and seal washers supplied by Kooltronic through the Air Conditioner side panel and int...

Страница 8: ...ed as high as possible within this area and equal or exceed size of cool air outlets WARM AIR RETURN FROM ENCLOSURE Enclosure opening should be located as high as possible within this area and equal o...

Страница 9: ...K2A4C9NP47L5 9000 125 50 230 50 10 0 150 160 KA3C10NP47R 10000 120 50 115 100 60 50 19 2 18 6 150 160 KA3C10NP47R56 10000 120 50 115 50 60 18 6 19 2 150 160 K2A4C10NP47L 10000 125 50 230 200 60 50 11...

Страница 10: ...ER COND PRESSURE SWITCH OPTIONAL START RELAY S L 2 1 M CAP COMPR 6 8 RELAY 0 1 UL LISTED UNITS ONLY OPTIONAL SWITCH CRANKCASE HEATER HEATER T STAT 55 T STAT 75 BU Y R THERMAL CUTOUT BU R PROTECTOR HEA...

Страница 11: ...off Continued operation under these conditions will cause damage shorten compressor life and void the warranty A Filter Removal and Service Kooltronic Air Conditioners feature an easily removable inle...

Страница 12: ...s valve fails it is strongly recommended that the Air Conditioner be returned to Kooltronic for service D Refrigerant Loss Kooltronic Air Conditioners are subjected to a series of tests to detect refr...

Страница 13: ...tat improperly set Low Temperature Control Replace Thermostat or Relay Thermostat defective when applicable Failed Compressor Replace Compressor Ice on Evaporator Coil Insufficient Heat Load or Unit C...

Страница 14: ...eceived by customer Number of parts to be returned Product description model and serial number Reason for return Action requested Contact name telephone FAX numbers and e mail address Pack unit in a s...

Отзывы: