B. Blowers

The design life of the blowers employed in all Kooltronic Air Conditioners is substantially in
excess of 20,000 hours. All Kooltronic condenser and evaporator blowers are equipped with
UL/CSA permanently-lubricated precision ball-bearing motors, with automatic-reset thermal
overload protectors.

CAUTION

If field replacement of a blower motor is necessary, most blower assemblies, including mounting
plate, are readily removable. Each of the blower mounting plates is held to the air conditioner
cabinet structure by screws and nuts. For installation of the replacement blower, electrical
connections may be broken at the terminal block, or power leads may be cut and appropriately
spliced together. 

C. Compressor

All Kooltronic compressors are approved by UL and CSA, and require no maintenance.
They are hermetically sealed and charged at the factory, and equipped with automatic-reset
thermal overload protectors.

If the compressor or the hot gas bypass valve fails, it is strongly recommended that the Air
Conditioner be returned to Kooltronic for service.

D. Refrigerant Loss

Kooltronic Air Conditioners are subjected to a series of tests to detect refrigerant leaks, during
and after manufacture. It is possible that shipping or other damage, or microscopic leaks over a
long period, may result in the need for replenishment of refrigerant charge.

When it has been

verified by a qualified professional that a refrigerant shortage does exist, the leak must be
repaired. Then the unit may be evacuated and recharged in the field by qualified service
people only.

CAUTION

E. Relocation

If your Kooltronic Air Conditioner has to be moved to another location by truck, the following
precautions should be taken:

I

De-mount Air Conditioner from equipment, controller or enclosure.

I

Conform to the applicable provisions of PROCEDURE FOR PROPER PACKING AND
SHIPMENT OF KOOLTRONIC AIR CONDITIONERS in this manual under 

Section III.

"PRODUCT HANDLING".

12

Before opening the Air Conditioner, disconnect all power.

Refer to the data on the unit name plate which specifies the type of refrigerant

and the amount of charge in ounces. 

Содержание K2A4C10NP47L

Страница 1: ...TANT THAT THIS MANUAL BE READ AND UNDERSTOOD THOROUGHLY KOOLTRONIC INC 30 Pennington Hopewell Road Pennington NJ 08534 609 466 3400 FAX 609 466 1114 TRIMLINE NP47 SERIES 7 000 10 000 BTU H 900 034 08...

Страница 2: ...ction Kooltronic Air Conditioners are designed to provide a cool dehumidified environment for your electronic components There are models to fit virtually all sizes and shapes of electronic enclosures...

Страница 3: ...position All Air Conditioners containing an MM NM P or V as part of the model number are designed to operate in a vertical position only All Air Conditioners containing an H RT or RM in the model num...

Страница 4: ...ements y Use of incorrect type or amount of refrigerant will adversely affect performance and may damage the unit r Make sure that these parameters are met Failure to do so may result in permanent dam...

Страница 5: ...nger The warm air inside the enclosure is drawn through the evaporator coil where it is cooled dehumidified and returned Any enclosure moisture accumulated on the evaporator coil is collected in the c...

Страница 6: ...ower will be delayed until the system pressures rise 10 Operate the air conditioner for approximately ten minutes During this period no unusual noise or vibration should be evident Both the evaporator...

Страница 7: ...B by sliding the studs located on each side panel into the slots on the M TAB 6 Insert the remaining 10 32 screws and seal washers supplied by Kooltronic through the Air Conditioner side panel and int...

Страница 8: ...ed as high as possible within this area and equal or exceed size of cool air outlets WARM AIR RETURN FROM ENCLOSURE Enclosure opening should be located as high as possible within this area and equal o...

Страница 9: ...K2A4C9NP47L5 9000 125 50 230 50 10 0 150 160 KA3C10NP47R 10000 120 50 115 100 60 50 19 2 18 6 150 160 KA3C10NP47R56 10000 120 50 115 50 60 18 6 19 2 150 160 K2A4C10NP47L 10000 125 50 230 200 60 50 11...

Страница 10: ...ER COND PRESSURE SWITCH OPTIONAL START RELAY S L 2 1 M CAP COMPR 6 8 RELAY 0 1 UL LISTED UNITS ONLY OPTIONAL SWITCH CRANKCASE HEATER HEATER T STAT 55 T STAT 75 BU Y R THERMAL CUTOUT BU R PROTECTOR HEA...

Страница 11: ...off Continued operation under these conditions will cause damage shorten compressor life and void the warranty A Filter Removal and Service Kooltronic Air Conditioners feature an easily removable inle...

Страница 12: ...s valve fails it is strongly recommended that the Air Conditioner be returned to Kooltronic for service D Refrigerant Loss Kooltronic Air Conditioners are subjected to a series of tests to detect refr...

Страница 13: ...tat improperly set Low Temperature Control Replace Thermostat or Relay Thermostat defective when applicable Failed Compressor Replace Compressor Ice on Evaporator Coil Insufficient Heat Load or Unit C...

Страница 14: ...eceived by customer Number of parts to be returned Product description model and serial number Reason for return Action requested Contact name telephone FAX numbers and e mail address Pack unit in a s...

Отзывы: