![Koolaire KD0172A Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/koolaire/kd0172a/kd0172a_technicians-handbook_1996839044.webp)
44
Part Number STH047 5/16
Removal from Service/Winterization
General
Special precautions must be taken if the ice machine is
to be removed from service for an extended period of
time or exposed to ambient temperatures of 32°F (0°C) or
below.
,
Caution
If water is allowed to remain in the ice machine in
freezing temperatures, severe damage to some
components could result. Damage of this nature is
not covered by the warranty.
Follow the applicable procedure below.
Self-contained Air-cooled Models
1. Disconnect the electric power at the circuit breaker
or the electric service switch.
2. Turn off the water supply.
3. Remove the water from the water trough.
4. Disconnect and drain the incoming ice-making
water line at the rear of the ice machine.
5. Blow compressed air in both the incoming water and
the drain openings in the rear of the ice machine
until no more water comes out of the inlet water
lines or the drain.
6. Make sure water is not trapped in any of the water
lines, drain lines, distribution tubes, etc.
Содержание KD0172A
Страница 2: ......
Страница 16: ...16 Part Number STH047 5 16 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 26: ...26 Part Number STH047 5 16 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 46: ...46 Part Number STH047 5 16 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 118: ...118 Part Number STH047 5 16 FIG A PINCHING OFF TUBING FIG B REROUNDING TUBING SV1406 Using Pinch Off Tool...
Страница 120: ...120 Part Number STH047 5 16 THIS PAGE INTENTIONALLY LEFT BLANK...